110544 Euchner Safety Accessories

110544 on MQ Automation
Euchner
  • 110544
  • 110544
  • 110544

Part#:110544

Alt. Part#:MGB-L2-APA-AA6A1-S3-R-110544

Manufacturer:Euchner

Category:Safety Accessories

Product Lifecycle:Active

Product description

110544 Euchner - Locking module MGB-L2-APA.. (guard locking by solenoid force) with 3 pushbuttons, incl. label carrier, M12 for enabling switch

Product Details

  • Weight
    2.27516784 lb
  • Series
    Spare parts
  • Product Class
    Accessories
  • PFHD
    3.7 x 10⁻⁹
  • Mission time
    20 y
  • Category
    4
  • Product version number
    V3.0.3
  • Performance Level
    PL e
  • Switching element
    1NO
  • Color
    white
  • Assignment diagram
    L1
  • Version
    Illuminated push buttons
  • Power supply LED
    24 V DC
  • Switching current
    1 ... 10 mA
  • Output voltage
    0 ... 1 V DC
  • Test-pulse interval
    min.100 ms
  • Breaking capacity
    max.0,25 W
  • Output current
    1 ... 200 mA
  • Switching voltage
    UA V
  • Type of output
    Semiconductor outputs, p-switching, short circuit-proof
  • Current consumption
    max.80 mA ((no load on outputs))
  • Operating voltage DC
    24 V DC -15% ... 10% ((Reverse polarity protected, regulated, residual ripple <5%, PELV))
  • Test pulses
    max.0,3 ms
  • Safety class
    III
  • Risk time according to EN 60947-5-3
    max.350 ms
  • Discrepancy time
    max.10 ms
  • Transponder coding
    Unicode
  • Connection cross-section
    0,13 ... 1,5 mm² ((AWG 24 ... AWG 16))
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Rated impulse withstand voltage Uimp
    1,5 kV
  • Utilization category acc. to EN 60947-5-2
    24V 200mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)
  • Rated insulation voltage Ui
    30 V
  • Locking force FZh
    2000 N
  • Guard locking principle
    Open-circuit current principle
  • Installation orientation
    Door hinge DIN right
  • Connection
    Plug connector SFF5 (X7)
  • Switching frequency
    0,25 Hz
  • Weight
    0,75 kg
  • Housing material
    Reinforced plastic; die-cast zinc nickel-plated, stainless steel
  • Degree of protection
    IP65
  • Ambient temperature
    -20 ... 55 °C
  • Mechanical life
    0,1 x 10⁶

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 110544 on MQ Automation is $1,507.01. Order now.


About the product

Guard locking with guard lock monitoring;3 pushbuttons (illuminated, wh, ye, bu);incl. adhesive labels;With cable entry;With plug connector M12 for enabling switch;Unicode


Manufacturer warranty

110544 Euchner

$1,507.01

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$1,507.01

$1,507.01 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 110544 with other products

Weight

Series

Product Class

PFHD

Mission time

Category

Product version number

Performance Level

Switching element

Color

Assignment diagram

Version

Power supply LED

Switching current

Output voltage

Test-pulse interval

Breaking capacity

Output current

Switching voltage

Type of output

Current consumption

Operating voltage DC

Test pulses

Safety class

Risk time according to EN...

Discrepancy time

Transponder coding

Connection cross-section

Degree of contamination (...

Rated impulse withstand v...

Utilization category acc....

Rated insulation voltage ...

Locking force FZh

Guard locking principle

Installation orientation

Connection

Switching frequency

Housing material

Degree of protection

Ambient temperature

Mechanical life

B10D

For the approval acc. to ...

Operating current

Repeat accuracy R

Detent mechanism

Off-state current Ir

Operating voltage

Turn-on time

Switching load

EMC protection requiremen...

Connection rating

Fusing

Overtravel

Extraction force

Actuating force

Shock and vibration resis...

Approach speed

Ready delay

Additional feature

Solenoid duty cycle

Solenoid operating voltag...

Extension of risk time ac...

Locking force Fmax

Retention force

Selected product

110544
0 in stock
110544
Euchner

110544 Euchner - Locking module MGB-L2-APA.. (guard locking by solenoid force) with 3 pushbuttons, i...

Weight2.27516784 lb

SeriesSpare parts

Product ClassAccessories

PFHD3.7 x 10⁻⁹

Mission time20 y

Category4

Product version numberV3.0.3

Performance LevelPL e

Switching element1NO

Colorwhite

Assignment diagramL1

VersionIlluminated push buttons

Power supply LED24 V DC

Switching current1 ... 10 mA

Output voltage0 ... 1 V DC

Test-pulse intervalmin.100 ms

Breaking capacitymax.0,25 W

Output current1 ... 200 mA

Switching voltageU<sub>A</sub> V

Type of outputSemiconductor outputs, p-swi...

Current consumptionmax.80 mA ((no load on outp...

Operating voltage DC24 V DC -15% ... 10% ((Re...

Test pulsesmax.0,3 ms

Safety classIII

Risk time according to EN 60947-5-3max.350 ms

Discrepancy timemax.10 ms

Transponder codingUnicode

Connection cross-section0,13 ... 1,5 mm² ((AWG 24 ....

Degree of contamination (external, according to EN 60947-1)3

Rated impulse withstand voltage Uimp1,5 kV

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Rated insulation voltage Ui30 V

Locking force FZh2000 N

Guard locking principleOpen-circuit current princip...

Installation orientationDoor hinge DIN right

ConnectionPlug connector SFF5 (X7)

Switching frequency0,25 Hz

Housing materialReinforced plastic; die-cast...

Degree of protectionIP65

Ambient temperature-20 ... 55 °C

Mechanical life0,1 x 10⁶

B10D-

For the approval acc. to UL the following applies-

Operating current-

Repeat accuracy R-

Detent mechanism-

Off-state current Ir-

Operating voltage-

Turn-on time-

Switching load-

EMC protection requirements-

Connection rating-

Fusing-

Overtravel-

Extraction force-

Actuating force-

Shock and vibration resistance-

Approach speed-

Ready delay-

Additional feature-

Solenoid duty cycle-

Solenoid operating voltage DC-

Extension of risk time according to EN 60947-5-3 per device-

Locking force Fmax-

Retention force-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

SeriesMGBS-P-I-AP

Product ClassSafety System

PFHD4.1 x 10 ⁻⁹

Mission time20 y

Category4

Product version number-

Performance LevelPL e

Switching element2 pos. driven NC

Color-

Assignment diagram-

VersionEmergency stop

Power supply LED-

Switching current1 ... 150 mA

Output voltage0 ... 1 V DC

Test-pulse intervalmin.100 ms

Breaking capacity-

Output current-

Switching voltage-

Type of output2 semiconductor outputs, p-s...

Current consumption40 mA

Operating voltage DC24 V DC -15% ... 15% Rev...

Test pulsesmax.0,3 ms (Applies for a l...

Safety classIII

Risk time according to EN 60947-5-3-

Discrepancy timemax.10 ms In acc. with EN ...

Transponder coding-

Connection cross-section-

Degree of contamination (external, according to EN 60947-1)3

Rated impulse withstand voltage Uimp0,5 kV

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Rated insulation voltage Ui50 V

Locking force FZh-

Guard locking principle-

Installation orientationDoor hinge DIN right

Connection2 plug connectors M12, 5-pin

Switching frequencymax.0,5 Hz

Housing materialFiber glass reinforced therm...

Degree of protectionIP65 (Screwed tight plug co...

Ambient temperature-20 ... +55 °C

Mechanical life1 x 10⁶

B10D0,13 x 10⁶

For the approval acc. to UL the following appliesOperation only with UL class...

Operating current1 ... 100 mA

Repeat accuracy R10 %

Detent mechanismSnap-in bolt

Off-state current Irmax.0,25 mA

Operating voltage5 ... 24 V

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating1 W

Fusing0,25 ... 8 A

Overtravel5 mm

Extraction force20 N

Actuating force10 N

Shock and vibration resistanceIn acc. with EN 60947-5-3

Approach speedmax.20 m/min

Ready delaymax.1 s

Additional feature-

Solenoid duty cycle-

Solenoid operating voltage DC-

Extension of risk time according to EN 60947-5-3 per device-

Locking force Fmax-

Retention force-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

PFHD4.1 x 10 ⁻⁹

Mission time20 y

Category4

Product version number-

Performance LevelPL e

Switching element-

Color-

Assignment diagram-

Version-

Power supply LED-

Switching current1 ... 50 mA

Output voltage0,8xUB ... UB V DC

Test-pulse intervalmin.140 ms

Breaking capacity-

Output current-

Switching voltage-

Type of outputp-switching, short circuit-p...

Current consumption40 mA

Operating voltage DC24 V DC -15% ... 15% Rev...

Test pulsesmax.1,0 ms (Applies for a l...

Safety classIII

Risk time according to EN 60947-5-3max.260 ms

Discrepancy timemax.10 ms In acc. with EN ...

Transponder coding-

Connection cross-section-

Degree of contamination (external, according to EN 60947-1)3

Rated impulse withstand voltage Uimp0,5 kV

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Rated insulation voltage Ui50 V

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Guard locking principleClosed-circuit current princ...

Installation orientationAny

Connection2 plug connectors M12, 5 and...

Switching frequencymax.0,5 Hz

Housing materialDie-cast zinc

Degree of protectionIP67/IP69/IP69K (Screwed ti...

Ambient temperature-20 ... +55 °C

Mechanical life1 x 10⁶

B10D-

For the approval acc. to UL the following appliesOperation only with UL class...

Operating current-

Repeat accuracy R10 %

Detent mechanism-

Off-state current Irmax.0,25 mA

Operating voltage-

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating6 W

Fusing0,25 ... 8 A

Overtravel5 mm

Extraction force20 N

Actuating force10 N

Shock and vibration resistanceIn acc. with EN 60947-5-3

Approach speedmax.20 m/min

Ready delay8 s

Additional featureEscape release actuated by p...

Solenoid duty cycle100 %

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Locking force Fmax3900 N

Retention force20 N

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.