Part#:110498

Alt. Part#:MGB-L1-APA-AC6A1-S1-R-110498

Manufacturer:Euchner

Category:Safety Accessories

Product Lifecycle:Active

Product description

110498 Euchner - Locking module MGB-L1-APA.. (guard locking by spring force) with 3 pushbuttons, emergency stop, RC18

Product Details

  • Weight
    2.3920127 lb
  • Series
    Spare parts
  • Product Class
    Accessories
  • Mission time
    20 y
  • B10D
    0,13 x 10⁶
  • PFHD
    3.7 x 10⁻⁹
  • Performance Level
    PL e
  • Special features
    With auxiliary contact
  • Category
    4
  • Product version number
    V4.0.0
  • Switching element
    2 pos. driven NC + 1NO
  • Version
    Emergency stop
  • Breaking capacity
    max.0,25 W
  • Assignment diagram
    L1
  • Test pulses
    max.0,3 ms
  • Switching voltage
    UA V
  • Power supply LED
    24 V DC
  • Output voltage
    UB-2V ... UB V DC (Value at a switching current of 50mA without taking into account the cable lengths)
  • Switching current
    1 ... 10 mA
  • Test-pulse interval
    min.100 ms
  • Type of output
    Semiconductor outputs, p-switching, short circuit-proof
  • Output current
    1 ... 200 mA
  • Operating voltage DC
    24 V DC -15% ... 10% ((Reverse polarity protected, regulated, residual ripple <5%, PELV))
  • Risk time according to EN 60947-5-3
    max.350 ms
  • Current consumption
    max.80 mA ((no load on outputs))
  • Utilization category acc. to EN 60947-5-2
    24V 200mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)
  • Transponder coding
    Unicode
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Locking force FZh
    2000 N
  • Discrepancy time
    max.10 ms
  • Rated impulse withstand voltage Uimp
    1,5 kV
  • Safety class
    III
  • Connection
    Plug connector RC18 (X6)
  • Rated insulation voltage Ui
    30 V
  • Installation orientation
    Door hinge DIN right
  • Switching frequency
    0,25 Hz
  • Ambient temperature
    -20 ... 55 °C
  • Degree of protection
    IP65
  • Mechanical life
    0,1 x 10⁶
  • Guard locking principle
    Closed-circuit current principle
  • Weight
    0,75 kg
  • Housing material
    Reinforced plastic; die-cast zinc nickel-plated, stainless steel

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 110498 on MQ Automation is $1,696.98. Order now.


About the product

Guard locking with guard lock monitoring;Emergency stop according to ISO 13850;2 pushbuttons, illuminated (gn, wh);1 pushbutton, not illuminated (wh);With plug connector RC18;Unicode


Manufacturer warranty

110498 Euchner

$1,696.98

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$1,696.98

$1,696.98 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 110498 with other products

Weight

Series

Product Class

Mission time

B10D

PFHD

Performance Level

Special features

Category

Product version number

Switching element

Version

Breaking capacity

Assignment diagram

Test pulses

Switching voltage

Power supply LED

Output voltage

Switching current

Test-pulse interval

Type of output

Output current

Operating voltage DC

Risk time according to EN...

Current consumption

Utilization category acc....

Transponder coding

Degree of contamination (...

Locking force FZh

Discrepancy time

Rated impulse withstand v...

Safety class

Connection

Rated insulation voltage ...

Installation orientation

Switching frequency

Ambient temperature

Degree of protection

Mechanical life

Guard locking principle

Housing material

For the approval acc. to ...

Operating current

Repeat accuracy R

Detent mechanism

Off-state current Ir

Operating voltage

Turn-on time

Switching load

EMC protection requiremen...

Connection rating

Fusing

Overtravel

Extraction force

Actuating force

Shock and vibration resis...

Approach speed

Ready delay

Additional feature

Solenoid duty cycle

Solenoid operating voltag...

Extension of risk time ac...

Locking force Fmax

Retention force

Selected product

110498
0 in stock
110498
Euchner

110498 Euchner - Locking module MGB-L1-APA.. (guard locking by spring force) with 3 pushbuttons, eme...

Weight2.3920127 lb

SeriesSpare parts

Product ClassAccessories

Mission time20 y

B10D0,13 x 10⁶

PFHD3.7 x 10⁻⁹

Performance LevelPL e

Special featuresWith auxiliary contact

Category4

Product version numberV4.0.0

Switching element2 pos. driven NC + 1NO

VersionEmergency stop

Breaking capacitymax.0,25 W

Assignment diagramL1

Test pulsesmax.0,3 ms

Switching voltageU<sub>A</sub> V

Power supply LED24 V DC

Output voltageUB-2V ... UB V DC (Value at...

Switching current1 ... 10 mA

Test-pulse intervalmin.100 ms

Type of outputSemiconductor outputs, p-swi...

Output current1 ... 200 mA

Operating voltage DC24 V DC -15% ... 10% ((Re...

Risk time according to EN 60947-5-3max.350 ms

Current consumptionmax.80 mA ((no load on outp...

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Transponder codingUnicode

Degree of contamination (external, according to EN 60947-1)3

Locking force FZh2000 N

Discrepancy timemax.10 ms

Rated impulse withstand voltage Uimp1,5 kV

Safety classIII

ConnectionPlug connector RC18 (X6)

Rated insulation voltage Ui30 V

Installation orientationDoor hinge DIN right

Switching frequency0,25 Hz

Ambient temperature-20 ... 55 °C

Degree of protectionIP65

Mechanical life0,1 x 10⁶

Guard locking principleClosed-circuit current princ...

Housing materialReinforced plastic; die-cast...

For the approval acc. to UL the following applies-

Operating current-

Repeat accuracy R-

Detent mechanism-

Off-state current Ir-

Operating voltage-

Turn-on time-

Switching load-

EMC protection requirements-

Connection rating-

Fusing-

Overtravel-

Extraction force-

Actuating force-

Shock and vibration resistance-

Approach speed-

Ready delay-

Additional feature-

Solenoid duty cycle-

Solenoid operating voltage DC-

Extension of risk time according to EN 60947-5-3 per device-

Locking force Fmax-

Retention force-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

SeriesMGBS-P-I-AP

Product ClassSafety System

Mission time20 y

B10D0,13 x 10⁶

PFHD4.1 x 10 ⁻⁹

Performance LevelPL e

Special features-

Category4

Product version number-

Switching element2 pos. driven NC

VersionEmergency stop

Breaking capacity-

Assignment diagram-

Test pulsesmax.0,3 ms (Applies for a l...

Switching voltage-

Power supply LED-

Output voltage0 ... 1 V DC

Switching current1 ... 150 mA

Test-pulse intervalmin.100 ms

Type of output2 semiconductor outputs, p-s...

Output current-

Operating voltage DC24 V DC -15% ... 15% Rev...

Risk time according to EN 60947-5-3-

Current consumption40 mA

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Transponder coding-

Degree of contamination (external, according to EN 60947-1)3

Locking force FZh-

Discrepancy timemax.10 ms In acc. with EN ...

Rated impulse withstand voltage Uimp0,5 kV

Safety classIII

Connection2 plug connectors M12, 5-pin

Rated insulation voltage Ui50 V

Installation orientationDoor hinge DIN right

Switching frequencymax.0,5 Hz

Ambient temperature-20 ... +55 °C

Degree of protectionIP65 (Screwed tight plug co...

Mechanical life1 x 10⁶

Guard locking principle-

Housing materialFiber glass reinforced therm...

For the approval acc. to UL the following appliesOperation only with UL class...

Operating current1 ... 100 mA

Repeat accuracy R10 %

Detent mechanismSnap-in bolt

Off-state current Irmax.0,25 mA

Operating voltage5 ... 24 V

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating1 W

Fusing0,25 ... 8 A

Overtravel5 mm

Extraction force20 N

Actuating force10 N

Shock and vibration resistanceIn acc. with EN 60947-5-3

Approach speedmax.20 m/min

Ready delaymax.1 s

Additional feature-

Solenoid duty cycle-

Solenoid operating voltage DC-

Extension of risk time according to EN 60947-5-3 per device-

Locking force Fmax-

Retention force-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

Mission time20 y

B10D-

PFHD4.1 x 10 ⁻⁹

Performance LevelPL e

Special features-

Category4

Product version number-

Switching element-

Version-

Breaking capacity-

Assignment diagram-

Test pulsesmax.1,0 ms (Applies for a l...

Switching voltage-

Power supply LED-

Output voltage0,8xUB ... UB V DC

Switching current1 ... 50 mA

Test-pulse intervalmin.140 ms

Type of outputp-switching, short circuit-p...

Output current-

Operating voltage DC24 V DC -15% ... 15% Rev...

Risk time according to EN 60947-5-3max.260 ms

Current consumption40 mA

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Transponder coding-

Degree of contamination (external, according to EN 60947-1)3

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Discrepancy timemax.10 ms In acc. with EN ...

Rated impulse withstand voltage Uimp0,5 kV

Safety classIII

Connection2 plug connectors M12, 5 and...

Rated insulation voltage Ui50 V

Installation orientationAny

Switching frequencymax.0,5 Hz

Ambient temperature-20 ... +55 °C

Degree of protectionIP67/IP69/IP69K (Screwed ti...

Mechanical life1 x 10⁶

Guard locking principleClosed-circuit current princ...

Housing materialDie-cast zinc

For the approval acc. to UL the following appliesOperation only with UL class...

Operating current-

Repeat accuracy R10 %

Detent mechanism-

Off-state current Irmax.0,25 mA

Operating voltage-

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating6 W

Fusing0,25 ... 8 A

Overtravel5 mm

Extraction force20 N

Actuating force10 N

Shock and vibration resistanceIn acc. with EN 60947-5-3

Approach speedmax.20 m/min

Ready delay8 s

Additional featureEscape release actuated by p...

Solenoid duty cycle100 %

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Locking force Fmax3900 N

Retention force20 N

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 110498?
The price of 110498 on MQ Automation is $1,696.98. Order now.

Out if stock but available for backorder.

110498 Euchner - Locking module MGB-L1-APA.. (guard locking by spring force) with 3 pushbuttons, emergency stop, RC18

What can I help you find today?

Recommended parts