109765 Euchner Safety Accessories
Part#:109765
Alt. Part#:MGB-L2-APA-AB6A1-S1-R-109765
Manufacturer:Euchner
Category:Safety Accessories
Product Lifecycle:Active
Product description
109765 Euchner - Locking module MGB-L2-APA.., (guard locking by solenoid force) with 2 pushbuttons, emergency stop, RC18
Product Details
- Weight 2.38980808 lb
- Series Spare parts
- Product Class Accessories
- Mission time 20 y
- Performance Level PL e
- Category 4
- PFHD 3.7 x 10⁻⁹
- B10D 0,13 x 10⁶
- Product version number V4.0.0
- Switching element 2 pos. driven NC
- Assignment diagram L1
- Version Emergency stop illuminated
- Test pulses max.5 ms
- Power supply LED 24 V DC
- Test-pulse interval min.100 ms
- Switching voltage UA V
- Breaking capacity max.0,25 W
- Switching current 1 ... 10 mA
- Output current max.50 mA
- Output voltage UA-2V ... UA V DC (Value at a switching current of 50mA without taking into account the cable lengths)
- Operating voltage DC 24 V DC -15% ... 10% ((Reverse polarity protected, regulated, residual ripple <5%, PELV))
- Type of output Semiconductor outputs, p-switching, short circuit-proof
- Current consumption max.80 mA ((no load on outputs))
- Transponder coding Unicode
- Risk time according to EN 60947-5-3 max.350 ms
- Discrepancy time max.10 ms
- Safety class III
- Degree of contamination (external, according to EN 60947-1) 3
- Rated impulse withstand voltage Uimp 1,5 kV
- Rated insulation voltage Ui 30 V
- Utilization category acc. to EN 60947-5-2 24V 200mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)
- Guard locking principle Open-circuit current principle
- Locking force FZh 2000 N
- Connection Plug connector RC18 (X6)
- Installation orientation Door hinge DIN right
- Mechanical life 0,1 x 10⁶
- Switching frequency 0,25 Hz
- Degree of protection IP65
- Weight 0,75 kg
- Ambient temperature -20 ... 55 °C
- Housing material Reinforced plastic; die-cast zinc nickel-plated, stainless steel
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 109765 on MQ Automation is $1,548.33. Order now.
About the product
Guard locking with guard lock monitoring;Emergency stop according to ISO 13850 (illuminated);2 pushbuttons (illuminated, wh, wh);incl. adhesive labels;With plug connector RC18;Unicode
Manufacturer warranty
109765 Euchner
$1,548.33
Your price can be lower.
Log in or Create account to check your discount
Select Qty:
$1,548.33
$1,548.33 each
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Manufacturer warranty
Got Questions? We've Got Answers!
Need more details?
Feel free to chat with us
Compare 109765 with other products
Weight
Series
Product Class
Mission time
Performance Level
Category
PFHD
B10D
Product version number
Switching element
Assignment diagram
Version
Test pulses
Power supply LED
Test-pulse interval
Switching voltage
Breaking capacity
Switching current
Output current
Output voltage
Operating voltage DC
Type of output
Current consumption
Transponder coding
Risk time according to EN...
Discrepancy time
Safety class
Degree of contamination (...
Rated impulse withstand v...
Rated insulation voltage ...
Utilization category acc....
Guard locking principle
Locking force FZh
Connection
Installation orientation
Mechanical life
Switching frequency
Degree of protection
Ambient temperature
Housing material
For the approval acc. to ...
Operating current
Repeat accuracy R
Detent mechanism
Off-state current Ir
Operating voltage
Turn-on time
Switching load
EMC protection requiremen...
Connection rating
Fusing
Overtravel
Extraction force
Actuating force
Shock and vibration resis...
Approach speed
Ready delay
Additional feature
Solenoid duty cycle
Solenoid operating voltag...
Extension of risk time ac...
Locking force Fmax
Retention force
Selected product

109765
Euchner
109765 Euchner - Locking module MGB-L2-APA.., (guard locking by solenoid force) with 2 pushbuttons, ...
Weight2.38980808 lb
SeriesSpare parts
Product ClassAccessories
Mission time20 y
Performance LevelPL e
Category4
PFHD3.7 x 10⁻⁹
B10D0,13 x 10⁶
Product version numberV4.0.0
Switching element2 pos. driven NC
Assignment diagramL1
VersionEmergency stop illuminated
Test pulsesmax.5 ms
Power supply LED24 V DC
Test-pulse intervalmin.100 ms
Switching voltageU<sub>A</sub> V
Breaking capacitymax.0,25 W
Switching current1 ... 10 mA
Output currentmax.50 mA
Output voltageUA-2V ... UA V DC (Value at...
Operating voltage DC24 V DC -15% ... 10% ((Re...
Type of outputSemiconductor outputs, p-swi...
Current consumptionmax.80 mA ((no load on outp...
Transponder codingUnicode
Risk time according to EN 60947-5-3max.350 ms
Discrepancy timemax.10 ms
Safety classIII
Degree of contamination (external, according to EN 60947-1)3
Rated impulse withstand voltage Uimp1,5 kV
Rated insulation voltage Ui30 V
Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...
Guard locking principleOpen-circuit current princip...
Locking force FZh2000 N
ConnectionPlug connector RC18 (X6)
Installation orientationDoor hinge DIN right
Mechanical life0,1 x 10⁶
Switching frequency0,25 Hz
Degree of protectionIP65
Ambient temperature-20 ... 55 °C
Housing materialReinforced plastic; die-cast...
For the approval acc. to UL the following applies-
Operating current-
Repeat accuracy R-
Detent mechanism-
Off-state current Ir-
Operating voltage-
Turn-on time-
Switching load-
EMC protection requirements-
Connection rating-
Fusing-
Overtravel-
Extraction force-
Actuating force-
Shock and vibration resistance-
Approach speed-
Ready delay-
Additional feature-
Solenoid duty cycle-
Solenoid operating voltage DC-
Extension of risk time according to EN 60947-5-3 per device-
Locking force Fmax-
Retention force-
Weight3.968316 lb
SeriesMGBS-P-I-AP
Product ClassSafety System
Mission time20 y
Performance LevelPL e
Category4
PFHD4.1 x 10 ⁻⁹
B10D0,13 x 10⁶
Product version number-
Switching element2 pos. driven NC
Assignment diagram-
VersionEmergency stop
Test pulsesmax.0,3 ms (Applies for a l...
Power supply LED-
Test-pulse intervalmin.100 ms
Switching voltage-
Breaking capacity-
Switching current1 ... 150 mA
Output current-
Output voltage0 ... 1 V DC
Operating voltage DC24 V DC -15% ... 15% Rev...
Type of output2 semiconductor outputs, p-s...
Current consumption40 mA
Transponder coding-
Risk time according to EN 60947-5-3-
Discrepancy timemax.10 ms In acc. with EN ...
Safety classIII
Degree of contamination (external, according to EN 60947-1)3
Rated impulse withstand voltage Uimp0,5 kV
Rated insulation voltage Ui50 V
Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...
Guard locking principle-
Locking force FZh-
Connection2 plug connectors M12, 5-pin
Installation orientationDoor hinge DIN right
Mechanical life1 x 10⁶
Switching frequencymax.0,5 Hz
Degree of protectionIP65 (Screwed tight plug co...
Ambient temperature-20 ... +55 °C
Housing materialFiber glass reinforced therm...
For the approval acc. to UL the following appliesOperation only with UL class...
Operating current1 ... 100 mA
Repeat accuracy R10 %
Detent mechanismSnap-in bolt
Off-state current Irmax.0,25 mA
Operating voltage5 ... 24 V
Turn-on timemax.400 ms
Switching load24V DC, class 2 (Alternativ...
EMC protection requirementsIn acc. with EN IEC 60947-5-...
Connection rating1 W
Fusing0,25 ... 8 A
Overtravel5 mm
Extraction force20 N
Actuating force10 N
Shock and vibration resistanceIn acc. with EN 60947-5-3
Approach speedmax.20 m/min
Ready delaymax.1 s
Additional feature-
Solenoid duty cycle-
Solenoid operating voltage DC-
Extension of risk time according to EN 60947-5-3 per device-
Locking force Fmax-
Retention force-

122813
Euchner
122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release
Weight1.763696 lb
SeriesCTP-AR
Product ClassSafety System
Mission time20 y
Performance LevelPL e
Category4
PFHD4.1 x 10 ⁻⁹
B10D-
Product version number-
Switching element-
Assignment diagram-
Version-
Test pulsesmax.1,0 ms (Applies for a l...
Power supply LED-
Test-pulse intervalmin.140 ms
Switching voltage-
Breaking capacity-
Switching current1 ... 50 mA
Output current-
Output voltage0,8xUB ... UB V DC
Operating voltage DC24 V DC -15% ... 15% Rev...
Type of outputp-switching, short circuit-p...
Current consumption40 mA
Transponder coding-
Risk time according to EN 60947-5-3max.260 ms
Discrepancy timemax.10 ms In acc. with EN ...
Safety classIII
Degree of contamination (external, according to EN 60947-1)3
Rated impulse withstand voltage Uimp0,5 kV
Rated insulation voltage Ui50 V
Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...
Guard locking principleClosed-circuit current princ...
Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...
Connection2 plug connectors M12, 5 and...
Installation orientationAny
Mechanical life1 x 10⁶
Switching frequencymax.0,5 Hz
Degree of protectionIP67/IP69/IP69K (Screwed ti...
Ambient temperature-20 ... +55 °C
Housing materialDie-cast zinc
For the approval acc. to UL the following appliesOperation only with UL class...
Operating current-
Repeat accuracy R10 %
Detent mechanism-
Off-state current Irmax.0,25 mA
Operating voltage-
Turn-on timemax.400 ms
Switching load24V DC, class 2 (Alternativ...
EMC protection requirementsIn acc. with EN IEC 60947-5-...
Connection rating6 W
Fusing0,25 ... 8 A
Overtravel5 mm
Extraction force20 N
Actuating force10 N
Shock and vibration resistanceIn acc. with EN 60947-5-3
Approach speedmax.20 m/min
Ready delay8 s
Additional featureEscape release actuated by p...
Solenoid duty cycle100 %
Solenoid operating voltage DC24 V DC -15% ... +10% Re...
Extension of risk time according to EN 60947-5-3 per devicemax.5 ms
Locking force Fmax3900 N
Retention force20 N

109765
Euchner
109765 Euchner - Locking module MGB-L2-APA.., (guard locking by solenoid force) with 2 pushbuttons, ...
Weight2.38980808 lb
SeriesSpare parts
Product ClassAccessories
Mission time20 y
Performance LevelPL e
Category4
PFHD3.7 x 10⁻⁹
B10D0,13 x 10⁶
Product version numberV4.0.0
Switching element2 pos. driven NC
Assignment diagramL1
VersionEmergency stop illuminated
Test pulsesmax.5 ms
Power supply LED24 V DC
Test-pulse intervalmin.100 ms
Switching voltageU<sub>A</sub> V
Breaking capacitymax.0,25 W
Switching current1 ... 10 mA
Output currentmax.50 mA
Output voltageUA-2V ... UA V DC (Value at...
Operating voltage DC24 V DC -15% ... 10% ((Re...
Type of outputSemiconductor outputs, p-swi...
Current consumptionmax.80 mA ((no load on outp...
Transponder codingUnicode
Risk time according to EN 60947-5-3max.350 ms
Discrepancy timemax.10 ms
Safety classIII
Degree of contamination (external, according to EN 60947-1)3
Rated impulse withstand voltage Uimp1,5 kV
Rated insulation voltage Ui30 V
Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...
Guard locking principleOpen-circuit current princip...
Locking force FZh2000 N
ConnectionPlug connector RC18 (X6)
Installation orientationDoor hinge DIN right
Mechanical life0,1 x 10⁶
Switching frequency0,25 Hz
Degree of protectionIP65
Ambient temperature-20 ... 55 °C
Housing materialReinforced plastic; die-cast...
For the approval acc. to UL the following applies-
Operating current-
Repeat accuracy R-
Detent mechanism-
Off-state current Ir-
Operating voltage-
Turn-on time-
Switching load-
EMC protection requirements-
Connection rating-
Fusing-
Overtravel-
Extraction force-
Actuating force-
Shock and vibration resistance-
Approach speed-
Ready delay-
Additional feature-
Solenoid duty cycle-
Solenoid operating voltage DC-
Extension of risk time according to EN 60947-5-3 per device-
Locking force Fmax-
Retention force-
About the manufacturer

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.
Recently viewed products
Relevant products
FAQ
What is the price of 109765?
The price of 109765 on MQ Automation is $1,548.33. Order now.
Out if stock but available for backorder.
109765 Euchner - Locking module MGB-L2-APA.., (guard locking by solenoid force) with 2 pushbuttons, emergency stop, RC18
Similar products from: Safety Accessories
What can I help you find today?