109401 Euchner Safety Proximity Sensors

109401 on MQ Automation
Euchner
  • 109401
  • 109401
  • 109401

Part#:109401

Alt. Part#:CET3-AR-CRA-AH-50X-SG-109401

Manufacturer:Euchner

Category:Safety Proximity Sensors

Product Lifecycle:Active

53 in stock

Mar 15, 2025

Product description

109401 Euchner - Non-contact safety switch CET-AR-..., M12

Product Details

  • Weight
    2.7998674 lb
  • Series
    CET-AR
  • Product Class
    Safety System
  • PFHD
    3.1 x 10⁻⁹
  • Mission time
    20 y
  • Input voltage
    15 ... 27,6 V DC
  • Performance Level
    PL e
  • Repeat accuracy R
    10 %
  • For the approval acc. to UL the following applies
    Operation only with UL class 2 power supply, or equivalent measures see operating instructions
  • Category
    4
  • Switching delay from state change
    max.400 ms
  • Turn-on time
    400 ms
  • Discrepancy time
    max.10 ms
  • Output voltage
    0 ... 1 V DC
  • Risk time according to EN 60947-5-3
    max.400 ms
  • Off-state current Ir
    max.0,25 mA
  • Type of output
    2 semiconductor outputs, p-switching, short circuit-proof
  • Switching current
    1 ... 200 mA
  • Extension of risk time according to EN 60947-5-3 per device
    max.5 ms
  • Safety class
    III
  • Switching load
    24V DC, class 2 (For alternatives see operating instructions)
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Connecting cable
    30V DC, 2A (For UL requirement UL category code (CYJV/CYJV7))
  • Fusing
    0,5 ... 8 A
  • EMC protection requirements
    In acc. with EN IEC 60947-5-3
  • Solenoid duty cycle
    100 %
  • Connection rating
    11 W
  • Solenoid operating voltage DC
    24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV
  • Utilization category acc. to EN 60947-5-2
    24V 200mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads)
  • Current consumption
    80 mA
  • Approach speed
    max.20 m/min
  • Locking force Fmax
    6500 N
  • Guard locking principle
    Closed-circuit current principle
  • Connection
    2 plug connectors M12, 5 and 8-pin
  • Locking force FZh
    5000 N (FZH = FMAX/1.3)
  • Operating voltage DC
    24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV
  • Switching frequency
    max.0,5 Hz
  • Ready delay
    10 s
  • Installation orientation
    Any (Preferably head downward)
  • Weight
    1 kg
  • Mechanical life
    1 x 10⁶
  • Ambient temperature
    -20 ... 55 °C
  • Shock and vibration resistance
    In acc. with EN 60947-5-3
  • Housing material
    Stainless steel
  • Degree of freedom Y
    ±5 mm
  • Degree of freedom Z
    ±4 mm
  • Degree of protection
    IP67 (Screwed tight plug connector/mating component)
  • Degree of freedom X
    ±5 mm

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 109401 on MQ Automation is $953.54. Order now.


About the product

Safety switch with guard locking and integrated evaluation electronics;Locking force up to 6500 N;Up to 20 switches in series;Short circuit monitoring;2 safety outputs (semiconductor outputs);Category 4 / PL e according to EN ISO 13849-1;With 2 plug connectors M12;Unicode;Door monitoring output;Indication of the door position by LED;Teach-in input;Approach direction A (delivery state)


This item can ship in 3-5 days!

Manufacturer warranty

109401 Euchner

$953.54

Your price can be lower.
Log in or Create account to check your discount

Stock:

53

Select Qty:

$953.54

$953.54 each

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 109401 with other products

Weight

Series

Product Class

PFHD

Mission time

Input voltage

Performance Level

Repeat accuracy R

For the approval acc. to ...

Category

Switching delay from stat...

Turn-on time

Discrepancy time

Output voltage

Risk time according to EN...

Off-state current Ir

Type of output

Switching current

Extension of risk time ac...

Safety class

Switching load

Degree of contamination (...

Connecting cable

Fusing

EMC protection requiremen...

Solenoid duty cycle

Connection rating

Solenoid operating voltag...

Utilization category acc....

Current consumption

Approach speed

Locking force Fmax

Guard locking principle

Connection

Locking force FZh

Operating voltage DC

Switching frequency

Ready delay

Installation orientation

Mechanical life

Ambient temperature

Shock and vibration resis...

Housing material

Degree of freedom Y

Degree of freedom Z

Degree of protection

Degree of freedom X

Additional feature

Rated impulse withstand v...

Rated insulation voltage ...

Test pulses

Test-pulse interval

Actuating force

Extraction force

Overtravel

Retention force

B10D

Version

Operating current

Switching element

Detent mechanism

Operating voltage

Selected product

109401
53 in stock
109401
Euchner

109401 Euchner - Non-contact safety switch CET-AR-..., M12

Weight2.7998674 lb

SeriesCET-AR

Product ClassSafety System

PFHD3.1 x 10⁻⁹

Mission time20 y

Input voltage15 ... 27,6 V DC

Performance LevelPL e

Repeat accuracy R10 %

For the approval acc. to UL the following appliesOperation only with UL class...

Category4

Switching delay from state changemax.400 ms

Turn-on time400 ms

Discrepancy timemax.10 ms

Output voltage0 ... 1 V DC

Risk time according to EN 60947-5-3max.400 ms

Off-state current Irmax.0,25 mA

Type of output2 semiconductor outputs, p-s...

Switching current1 ... 200 mA

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Safety classIII

Switching load24V DC, class 2 (For altern...

Degree of contamination (external, according to EN 60947-1)3

Connecting cable30V DC, 2A (For UL requirem...

Fusing0,5 ... 8 A

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Solenoid duty cycle100 %

Connection rating11 W

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Current consumption80 mA

Approach speedmax.20 m/min

Locking force Fmax6500 N

Guard locking principleClosed-circuit current princ...

Connection2 plug connectors M12, 5 and...

Locking force FZh5000 N (FZH = FMAX/1.3)

Operating voltage DC24 V DC -15% ... 15% Rev...

Switching frequencymax.0,5 Hz

Ready delay10 s

Installation orientationAny (Preferably head downwa...

Mechanical life1 x 10⁶

Ambient temperature-20 ... 55 °C

Shock and vibration resistanceIn acc. with EN 60947-5-3

Housing materialStainless steel

Degree of freedom Y±5 mm

Degree of freedom Z±4 mm

Degree of protectionIP67 (Screwed tight plug co...

Degree of freedom X±5 mm

Additional feature-

Rated impulse withstand voltage Uimp-

Rated insulation voltage Ui-

Test pulses-

Test-pulse interval-

Actuating force-

Extraction force-

Overtravel-

Retention force-

B10D-

Version-

Operating current-

Switching element-

Detent mechanism-

Operating voltage-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

PFHD4.1 x 10 ⁻⁹

Mission time20 y

Input voltage-

Performance LevelPL e

Repeat accuracy R10 %

For the approval acc. to UL the following appliesOperation only with UL class...

Category4

Switching delay from state change-

Turn-on timemax.400 ms

Discrepancy timemax.10 ms In acc. with EN ...

Output voltage0,8xUB ... UB V DC

Risk time according to EN 60947-5-3max.260 ms

Off-state current Irmax.0,25 mA

Type of outputp-switching, short circuit-p...

Switching current1 ... 50 mA

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Safety classIII

Switching load24V DC, class 2 (Alternativ...

Degree of contamination (external, according to EN 60947-1)3

Connecting cable-

Fusing0,25 ... 8 A

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Solenoid duty cycle100 %

Connection rating6 W

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Current consumption40 mA

Approach speedmax.20 m/min

Locking force Fmax3900 N

Guard locking principleClosed-circuit current princ...

Connection2 plug connectors M12, 5 and...

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Operating voltage DC24 V DC -15% ... 15% Rev...

Switching frequencymax.0,5 Hz

Ready delay8 s

Installation orientationAny

Mechanical life1 x 10⁶

Ambient temperature-20 ... +55 °C

Shock and vibration resistanceIn acc. with EN 60947-5-3

Housing materialDie-cast zinc

Degree of freedom Y-

Degree of freedom Z-

Degree of protectionIP67/IP69/IP69K (Screwed ti...

Degree of freedom X-

Additional featureEscape release actuated by p...

Rated impulse withstand voltage Uimp0,5 kV

Rated insulation voltage Ui50 V

Test pulsesmax.1,0 ms (Applies for a l...

Test-pulse intervalmin.140 ms

Actuating force10 N

Extraction force20 N

Overtravel5 mm

Retention force20 N

B10D-

Version-

Operating current-

Switching element-

Detent mechanism-

Operating voltage-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

SeriesMGBS-P-I-AP

Product ClassSafety System

PFHD4.1 x 10 ⁻⁹

Mission time20 y

Input voltage-

Performance LevelPL e

Repeat accuracy R10 %

For the approval acc. to UL the following appliesOperation only with UL class...

Category4

Switching delay from state change-

Turn-on timemax.400 ms

Discrepancy timemax.10 ms In acc. with EN ...

Output voltage0 ... 1 V DC

Risk time according to EN 60947-5-3-

Off-state current Irmax.0,25 mA

Type of output2 semiconductor outputs, p-s...

Switching current1 ... 150 mA

Extension of risk time according to EN 60947-5-3 per device-

Safety classIII

Switching load24V DC, class 2 (Alternativ...

Degree of contamination (external, according to EN 60947-1)3

Connecting cable-

Fusing0,25 ... 8 A

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Solenoid duty cycle-

Connection rating1 W

Solenoid operating voltage DC-

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Current consumption40 mA

Approach speedmax.20 m/min

Locking force Fmax-

Guard locking principle-

Connection2 plug connectors M12, 5-pin

Locking force FZh-

Operating voltage DC24 V DC -15% ... 15% Rev...

Switching frequencymax.0,5 Hz

Ready delaymax.1 s

Installation orientationDoor hinge DIN right

Mechanical life1 x 10⁶

Ambient temperature-20 ... +55 °C

Shock and vibration resistanceIn acc. with EN 60947-5-3

Housing materialFiber glass reinforced therm...

Degree of freedom Y-

Degree of freedom Z-

Degree of protectionIP65 (Screwed tight plug co...

Degree of freedom X-

Additional feature-

Rated impulse withstand voltage Uimp0,5 kV

Rated insulation voltage Ui50 V

Test pulsesmax.0,3 ms (Applies for a l...

Test-pulse intervalmin.100 ms

Actuating force10 N

Extraction force20 N

Overtravel5 mm

Retention force-

B10D0,13 x 10⁶

VersionEmergency stop

Operating current1 ... 100 mA

Switching element2 pos. driven NC

Detent mechanismSnap-in bolt

Operating voltage5 ... 24 V

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 109401?
The price of 109401 on MQ Automation is $953.54. Order now.

Out if stock but available for backorder.

109401 Euchner - Non-contact safety switch CET-AR-..., M12

What can I help you find today?

Recommended parts