106602 Euchner Safety Proximity Sensors

106602 on MQ Automation
Euchner
  • 106602
  • 106602
  • 106602

Part#:106602

Alt. Part#:CES-A-LNN-05V-106602

Manufacturer:Euchner

Category:Safety Proximity Sensors

Product Lifecycle:Active

Product description

106602 Euchner - Read head CES-A-LNN-...hard-wired encapsulated cable 5 m, PVC

Product Details

  • Weight
    0.4188778 lb
  • Series
    CES read heads
  • Product Class
    Safety System
  • Connecting cable
    PVC, length 5m, Ø 4.6 mm, with crimped ferrules
  • LED indicator
    White: valid actuator detected
  • Power supply
    Via evaluation unit
  • Tightening torque
    max.1 Nm
  • Cable length
    max.25 m
  • Degree of protection
    IP67
  • Installation orientation
    Any
  • Method of operation
    Inductive
  • Connection
    Hard-wired encapsulated connection cable
  • Housing material
    Reinforced thermoplastic (PBT), fully encapsulated
  • Weight
    0,025 kg ((Without cable))
  • Ambient temperature
    -25 ... 70 °C

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 106602 on MQ Automation is $75.70. Order now.


About the product

Cube-shaped design 42 x 25 mm;Mounting compatible with series CES-A-LNA/LCA;LED for indicating the door position;Hard-wired encapsulated cable, PVC;Cable length 5 m


Manufacturer warranty

106602 Euchner

$75.70

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$75.70

$75.70 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 106602 with other products

Weight

Series

Product Class

Connecting cable

LED indicator

Power supply

Tightening torque

Cable length

Degree of protection

Installation orientation

Method of operation

Connection

Housing material

Ambient temperature

Switching hysteresis

Assured operating distanc...

Assured release distance ...

PFHD

Operating distance

Mission time

Performance Level

Category

For the approval acc. to ...

Repeat accuracy R

Discrepancy time

Off-state current Ir

Utilization category acc....

Rated conditional short-c...

Test pulses

Test-pulse interval

Output voltage

Switching current

Turn-on time

Risk time according to EN...

Type of output

Fusing

Rated impulse withstand v...

Rated insulation voltage ...

Degree of contamination (...

Safety class

EMC protection requiremen...

Extension of risk time ac...

Current consumption

Mounting distance

Operating voltage DC

Switching frequency

Ready delay

Cable ambient temperature...

Mounting method

Static bending radius

Shock and vibration resis...

Cable ambient temperature...

Dynamic bending radius

Selected product

106602
0 in stock
106602
Euchner

106602 Euchner - Read head CES-A-LNN-...hard-wired encapsulated cable 5 m, PVC

Weight0.4188778 lb

SeriesCES read heads

Product ClassSafety System

Connecting cablePVC, length 5m, Ø 4.6 mm, wi...

LED indicatorWhite: valid actuator detect...

Power supplyVia evaluation unit

Tightening torquemax.1 Nm

Cable lengthmax.25 m

Degree of protectionIP67

Installation orientationAny

Method of operationInductive

ConnectionHard-wired encapsulated conn...

Housing materialReinforced thermoplastic (PB...

Ambient temperature-25 ... 70 °C

Switching hysteresis-

Assured operating distance Sao-

Assured release distance Sar-

PFHD-

Operating distance-

Mission time-

Performance Level-

Category-

For the approval acc. to UL the following applies-

Repeat accuracy R-

Discrepancy time-

Off-state current Ir-

Utilization category acc. to EN 60947-5-2-

Rated conditional short-circuit current-

Test pulses-

Test-pulse interval-

Output voltage-

Switching current-

Turn-on time-

Risk time according to EN 60947-5-3-

Type of output-

Fusing-

Rated impulse withstand voltage Uimp-

Rated insulation voltage Ui-

Degree of contamination (external, according to EN 60947-1)-

Safety class-

EMC protection requirements-

Extension of risk time according to EN 60947-5-3 per device-

Current consumption-

Mounting distance-

Operating voltage DC-

Switching frequency-

Ready delay-

Cable ambient temperature (dynamic)-

Mounting method-

Static bending radius-

Shock and vibration resistance-

Cable ambient temperature (static)-

Dynamic bending radius-

105748
2 in stock
105748
Euchner

105748 Euchner - Non-contact safety switch CES-AR-CL2-... , plug connector M12, PUR

Weight0.29100984 lb

SeriesCES-AR

Product ClassSafety System

Connecting cable-

LED indicator-

Power supply-

Tightening torquemax.1 Nm

Cable length-

Degree of protectionIP67

Installation orientationAny

Method of operation-

ConnectionConnection cable PUR, length...

Housing materialPlastic, PBT

Ambient temperature-

Switching hysteresismin.1 mm

Assured operating distance Saomin.14 mm

Assured release distance Sarmax.60 mm

PFHD1.9 x 10⁻⁹

Operating distance19 mm

Mission time20

Performance LevelPL e

Category4

For the approval acc. to UL the following appliesOperation only with UL class...

Repeat accuracy R≤ 10

Discrepancy timemax.10 ms

Off-state current Irmax.0,25 mA

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Rated conditional short-circuit current100 A

Test pulsesmax.1 ms (Applies for a loa...

Test-pulse intervalmin.140 ms

Output voltage0,8 x UB ... UB V DC

Switching currentmax.50 mA

Turn-on timemax.400 ms

Risk time according to EN 60947-5-3max.260 ms

Type of outputp-switching, short circuit-p...

Fusing0,25 ... 8 A

Rated impulse withstand voltage Uimp1,5 kV

Rated insulation voltage Ui75 V

Degree of contamination (external, according to EN 60947-1)3

Safety classIII

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Current consumptionmax.50 mA (Without taking i...

Mounting distancemin.120 mm

Operating voltage DC24 V DC 15% ... 15% Regu...

Switching frequencymax.1 Hz

Ready delay10 s

Cable ambient temperature (dynamic)-25 ... 65 °C

Mounting methodSurface mounting on metal

Static bending radius5 x cable diameter

Shock and vibration resistanceIn acc. with EN 60947-5-3

Cable ambient temperature (static)-25 ... 65 °C

Dynamic bending radius10 x cable diameter

105602
3 in stock
105602
Euchner

105602 Euchner - Non-contact safety switch CES-AP-CL2-..., flying lead, PVC

Weight0.52029032 lb

SeriesCES-AP

Product ClassSafety System

Connecting cable-

LED indicator-

Power supply-

Tightening torquemax.1 Nm

Cable length-

Degree of protectionIP67, IP69K

Installation orientationAny

Method of operation-

Connectionconnection cable PVC, length...

Housing materialPlastic, PBT

Ambient temperature-

Switching hysteresismin.1 mm

Assured operating distance Saomin.14 mm

Assured release distance Sarmax.60 mm

PFHD1.8 x 10⁻⁹

Operating distance19 mm

Mission time20

Performance LevelPL e

Category4

For the approval acc. to UL the following appliesOperation only with UL class...

Repeat accuracy R≤ 10

Discrepancy timemax.10 ms

Off-state current Irmax.0,25 mA

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Rated conditional short-circuit current100 A

Test pulsesmax.0,3 ms (Applies for a l...

Test-pulse intervalmin.100 ms

Output voltage0,8 x UB ... UB V DC

Switching currentmax.50 mA

Turn-on timemax.300 ms

Risk time according to EN 60947-5-3max.260 ms

Type of outputp-switching, short circuit-p...

Fusing0,25 ... 8 A

Rated impulse withstand voltage Uimp1,5 kV

Rated insulation voltage Ui75 V

Degree of contamination (external, according to EN 60947-1)3

Safety classIII

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Extension of risk time according to EN 60947-5-3 per device-

Current consumptionmax.30 mA (Without taking i...

Mounting distancemin.400 mm

Operating voltage DC24 V DC 15% ... 15% Regu...

Switching frequencymax.1 Hz

Ready delay0,5 s

Cable ambient temperature (dynamic)0 ... 65 °C

Mounting methodSurface mounting on metal

Static bending radius5 x cable diameter

Shock and vibration resistanceIn acc. with EN 60947-5-3

Cable ambient temperature (static)-40 ... 65 °C

Dynamic bending radius10 x cable diameter

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 106602?
The price of 106602 on MQ Automation is $75.70. Order now.

Out if stock but available for backorder.

106602 Euchner - Read head CES-A-LNN-...hard-wired encapsulated cable 5 m, PVC

What can I help you find today?

Recommended parts