Product description

105802 Euchner - Non-contact safety switch CET-AR-..., M12

Product Details

  • Weight
    2.52649452 lb
  • Series
    CET-AR
  • Product Class
    Safety System
  • PFHD
    3.1 x 10⁻⁹
  • Mission time
    20 y
  • Performance Level
    PL e
  • Category
    4
  • For the approval acc. to UL the following applies
    Operation only with UL class 2 power supply, or equivalent measures see operating instructions
  • Output voltage
    UB-1,5V ... UB V DC (Values at a switching current of 50mA without taking into account the cable lengths)
  • Input voltage
    15 ... 27,6 V DC Feedback loop Y
  • Repeat accuracy R
    10 %
  • Discrepancy time
    max.10 ms
  • Turn-on time
    400 ms
  • Off-state current Ir
    max.0,25 mA
  • Risk time according to EN 60947-5-3
    max.400 ms
  • Type of output
    Semiconductor outputs, p-switching, short circuit-proof
  • Output current
    1 ... 200 mA
  • Extension of risk time according to EN 60947-5-3 per device
    max.5 ms
  • Switching load
    24V DC, class 2 (For alternatives see operating instructions)
  • Safety class
    III
  • Degree of contamination (external, according to EN 60947-1)
    3
  • EMC protection requirements
    In acc. with EN IEC 60947-5-3
  • Solenoid duty cycle
    100 %
  • Connection rating
    11 W
  • Utilization category acc. to EN 60947-5-2
    24V 200mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads)
  • Fusing
    0,25 ... 8 A
  • Solenoid operating voltage DC
    24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV
  • Connection
    2 plug connectors M12, 5 and 8-pin
  • Locking force FZh
    5000 N
  • Operating voltage DC
    24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV
  • Current consumption
    80 mA
  • Locking force Fmax
    6500 N
  • Switching frequency
    max.0,5 Hz
  • Approach speed
    max.20 m/min
  • Guard locking principle
    Closed-circuit current principle
  • Ready delay
    10 s
  • Degree of freedom X
    ±5 mm
  • Degree of freedom Y
    ±5 mm
  • Weight
    1 kg
  • Ambient temperature
    -20 ... 55 °C
  • Mechanical life
    1 x 10⁶
  • Installation orientation
    Any (Preferably head downward)
  • Degree of freedom Z
    ±4 mm
  • Degree of protection
    IP67 (Screwed tight plug connector/mating component)
  • Housing material
    Stainless steel

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 105802 on MQ Automation is $926.49. Order now.


About the product

Safety switch with guard locking and integrated evaluation electronics;Locking force up to 6500 N;Up to 20 switches in series;Short circuit monitoring;2 safety outputs (semiconductor outputs);Category 4 / PL e according to EN ISO 13849-1;With 2 plug connectors M12;Unicode;Feedback loop;Approach direction A (delivery state)


This item can ship in 3-5 days!

Manufacturer warranty

105802 Euchner

$926.49

Your price can be lower.
Log in or Create account to check your discount

Stock:

2

Select Qty:

$926.49

$926.49 each

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 105802 with other products

Weight

Series

Product Class

PFHD

Mission time

Performance Level

Category

For the approval acc. to ...

Output voltage

Input voltage

Repeat accuracy R

Discrepancy time

Turn-on time

Off-state current Ir

Risk time according to EN...

Type of output

Output current

Extension of risk time ac...

Switching load

Safety class

Degree of contamination (...

EMC protection requiremen...

Solenoid duty cycle

Connection rating

Utilization category acc....

Fusing

Solenoid operating voltag...

Connection

Locking force FZh

Operating voltage DC

Current consumption

Locking force Fmax

Switching frequency

Approach speed

Guard locking principle

Ready delay

Degree of freedom X

Degree of freedom Y

Ambient temperature

Mechanical life

Installation orientation

Degree of freedom Z

Degree of protection

Housing material

Additional feature

Switching current

Rated impulse withstand v...

Rated insulation voltage ...

Test pulses

Test-pulse interval

Actuating force

Extraction force

Overtravel

Retention force

Shock and vibration resis...

B10D

Version

Operating current

Switching element

Detent mechanism

Operating voltage

Selected product

105802
2 in stock
105802
Euchner

105802 Euchner - Non-contact safety switch CET-AR-..., M12

Weight2.52649452 lb

SeriesCET-AR

Product ClassSafety System

PFHD3.1 x 10⁻⁹

Mission time20 y

Performance LevelPL e

Category4

For the approval acc. to UL the following appliesOperation only with UL class...

Output voltageUB-1,5V ... UB V DC (Values...

Input voltage15 ... 27,6 V DC Feedback ...

Repeat accuracy R10 %

Discrepancy timemax.10 ms

Turn-on time400 ms

Off-state current Irmax.0,25 mA

Risk time according to EN 60947-5-3max.400 ms

Type of outputSemiconductor outputs, p-swi...

Output current1 ... 200 mA

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Switching load24V DC, class 2 (For altern...

Safety classIII

Degree of contamination (external, according to EN 60947-1)3

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Solenoid duty cycle100 %

Connection rating11 W

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Fusing0,25 ... 8 A

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Connection2 plug connectors M12, 5 and...

Locking force FZh5000 N

Operating voltage DC24 V DC -15% ... 15% Rev...

Current consumption80 mA

Locking force Fmax6500 N

Switching frequencymax.0,5 Hz

Approach speedmax.20 m/min

Guard locking principleClosed-circuit current princ...

Ready delay10 s

Degree of freedom X±5 mm

Degree of freedom Y±5 mm

Ambient temperature-20 ... 55 °C

Mechanical life1 x 10⁶

Installation orientationAny (Preferably head downwa...

Degree of freedom Z±4 mm

Degree of protectionIP67 (Screwed tight plug co...

Housing materialStainless steel

Additional feature-

Switching current-

Rated impulse withstand voltage Uimp-

Rated insulation voltage Ui-

Test pulses-

Test-pulse interval-

Actuating force-

Extraction force-

Overtravel-

Retention force-

Shock and vibration resistance-

B10D-

Version-

Operating current-

Switching element-

Detent mechanism-

Operating voltage-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

PFHD4.1 x 10 ⁻⁹

Mission time20 y

Performance LevelPL e

Category4

For the approval acc. to UL the following appliesOperation only with UL class...

Output voltage0,8xUB ... UB V DC

Input voltage-

Repeat accuracy R10 %

Discrepancy timemax.10 ms In acc. with EN ...

Turn-on timemax.400 ms

Off-state current Irmax.0,25 mA

Risk time according to EN 60947-5-3max.260 ms

Type of outputp-switching, short circuit-p...

Output current-

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Switching load24V DC, class 2 (Alternativ...

Safety classIII

Degree of contamination (external, according to EN 60947-1)3

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Solenoid duty cycle100 %

Connection rating6 W

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Fusing0,25 ... 8 A

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Connection2 plug connectors M12, 5 and...

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Operating voltage DC24 V DC -15% ... 15% Rev...

Current consumption40 mA

Locking force Fmax3900 N

Switching frequencymax.0,5 Hz

Approach speedmax.20 m/min

Guard locking principleClosed-circuit current princ...

Ready delay8 s

Degree of freedom X-

Degree of freedom Y-

Ambient temperature-20 ... +55 °C

Mechanical life1 x 10⁶

Installation orientationAny

Degree of freedom Z-

Degree of protectionIP67/IP69/IP69K (Screwed ti...

Housing materialDie-cast zinc

Additional featureEscape release actuated by p...

Switching current1 ... 50 mA

Rated impulse withstand voltage Uimp0,5 kV

Rated insulation voltage Ui50 V

Test pulsesmax.1,0 ms (Applies for a l...

Test-pulse intervalmin.140 ms

Actuating force10 N

Extraction force20 N

Overtravel5 mm

Retention force20 N

Shock and vibration resistanceIn acc. with EN 60947-5-3

B10D-

Version-

Operating current-

Switching element-

Detent mechanism-

Operating voltage-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

SeriesMGBS-P-I-AP

Product ClassSafety System

PFHD4.1 x 10 ⁻⁹

Mission time20 y

Performance LevelPL e

Category4

For the approval acc. to UL the following appliesOperation only with UL class...

Output voltage0 ... 1 V DC

Input voltage-

Repeat accuracy R10 %

Discrepancy timemax.10 ms In acc. with EN ...

Turn-on timemax.400 ms

Off-state current Irmax.0,25 mA

Risk time according to EN 60947-5-3-

Type of output2 semiconductor outputs, p-s...

Output current-

Extension of risk time according to EN 60947-5-3 per device-

Switching load24V DC, class 2 (Alternativ...

Safety classIII

Degree of contamination (external, according to EN 60947-1)3

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Solenoid duty cycle-

Connection rating1 W

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Fusing0,25 ... 8 A

Solenoid operating voltage DC-

Connection2 plug connectors M12, 5-pin

Locking force FZh-

Operating voltage DC24 V DC -15% ... 15% Rev...

Current consumption40 mA

Locking force Fmax-

Switching frequencymax.0,5 Hz

Approach speedmax.20 m/min

Guard locking principle-

Ready delaymax.1 s

Degree of freedom X-

Degree of freedom Y-

Ambient temperature-20 ... +55 °C

Mechanical life1 x 10⁶

Installation orientationDoor hinge DIN right

Degree of freedom Z-

Degree of protectionIP65 (Screwed tight plug co...

Housing materialFiber glass reinforced therm...

Additional feature-

Switching current1 ... 150 mA

Rated impulse withstand voltage Uimp0,5 kV

Rated insulation voltage Ui50 V

Test pulsesmax.0,3 ms (Applies for a l...

Test-pulse intervalmin.100 ms

Actuating force10 N

Extraction force20 N

Overtravel5 mm

Retention force-

Shock and vibration resistanceIn acc. with EN 60947-5-3

B10D0,13 x 10⁶

VersionEmergency stop

Operating current1 ... 100 mA

Switching element2 pos. driven NC

Detent mechanismSnap-in bolt

Operating voltage5 ... 24 V

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 105802?
The price of 105802 on MQ Automation is $926.49. Order now.

Out if stock but available for backorder.

105802 Euchner - Non-contact safety switch CET-AR-..., M12

What can I help you find today?

Recommended parts