105140 Euchner Safety Proximity Sensors
Part#:105140
Alt. Part#:CES-AZ-UES-02B
Manufacturer:Euchner
Category:Safety Proximity Sensors
Product Lifecycle:Active
Product description
105140 Euchner - Evaluation unit CES-AZ-UES-02B (for 2 read heads)
Product Details
- Weight 0.64815828 lb
- Series CES-AZ evaluation
- Product Class Safety System
- Switching hysteresis min.0,5 mm (These values apply for the surface installation of the read head and the actuator.)
- Assured operating distance Sao min.10 mm (These values apply for the surface installation of the read head and the actuator.)
- Assured release distance Sar max.26 mm
- Distance s, actuator min.3 mm
- Operating distance 15 mm (These values apply for the surface installation of the read head and the actuator.)
- Category 4 (This value is dependent on the number of switching cycles and the switching current.)
- Mission time 20 y (This value is dependent on the number of switching cycles and the switching current.)
- Number of switching cycles max.760000 1/Jahr
- PFHD 1.9 x 10⁻⁸ (This value is dependent on the number of switching cycles and the switching current.)
- Performance Level PL e (This value is dependent on the number of switching cycles and the switching current.)
- Diagnostic Coverage (DC) 99 %
- For the approval acc. to UL the following applies (Operation only with UL class 2 power supply or equivalent measures.)
- Repeat accuracy R max.10 %
- Rated conditional short-circuit current 100 A
- Rated impulse withstand voltage Uimp 4 kV
- Discrepancy time max.25 ms
- Rated insulation voltage Ui 250 V
- Switching load Class 2 max. 30 V AC / Class 2 max. 60 V DC; 120 V AC 3 A / 240 V AC 1.5 A
- Switching current 10 ... 6000 mA
- Utilization category acc. to EN 60947-5-1 230 V 2 A
- LED indicator Status LED
- Input voltage 0 ... 2 V DC
- Input current 5 ... 8 ... 10 mA
- Output current max.20 mA
- Type of output Semiconductor output, p-switching, short circuit-proof
- Output voltage 0,8 x UB ... UB V DC
- Current via feedback loop 5 ... 8 ... 10 mA
- permissible resistance in feedback loop max.600 Ω
- Degree of contamination (external, according to EN 60947-1) 2
- EMC protection requirements In acc. with EN 60947-5-3
- Connection cross-section 0,25 ... 2,5 mm²
- Dwell time min.3 s (The dwell time is the time that the actuator must be inside or outside the operating distance.)
- Fusing 0,25 ... 8 A
- Current consumption 150 mA (Without taking into account the load currents on the monitoring outputs)
- Switching frequency max.0,25 Hz (In case of monitoring with feedback loop, the actuators must remain outside the operating distance, e.g. with a door open, until the feedback circuit is closed.)
- Operating voltage DC 21 ... 24 ... 27 V DC Regulated, residual ripple < 5 %
- Reaction time min.250 ms
- Connection Plug-in connection terminals, coded (Terminals not included)
- Number of safety contacts 2 Relays with internally monitored contacts
- Mechanical life 10 x 10⁶
- Ambient temperature -20 ... 55 °C
- Mounting method Mounting rail 35mm according to DIN EN 60715 TH35
- Weight 0,25 kg
- Housing material Plastic PA6.6
- Mounting distance min.10 mm (If several evaluation units are mounted side by side in a control cabinet without air circulation (e.g. fan), a minimum distance of 10 mm must be maintained between the evaluation units. The distance enables heat from the evaluation unit to di
- Ready delay 10 ... 12 s (After the operating voltage is switched on, the relay outputs are switched off and the door monitoring outputs are set LOW during the ready delay. For the visual indication of the delay, the green STATE LED flashes at a frequency of approx.
- Number of read heads Max. 2 read heads can be connected
- Degree of protection IP20
- Atmospheric humidity max.80 % rH
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 105140 on MQ Automation is $523.68. Order now.
About the product
2 read heads can be connected;2 safety outputs (relay contacts with 2 internally connected NO contacts per output);Start button and feedback loop can be connected;Multicode;Plug-in connection terminals;Category 4 / PL e according to EN ISO 13849-1
Manufacturer warranty
105140 Euchner
$523.68
Your price can be lower.
Log in or Create account to check your discount
Select Qty:
$523.68
$523.68 each
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Manufacturer warranty
Got Questions? We've Got Answers!
Need more details?
Feel free to chat with us
Compare 105140 with other products
Weight
Series
Product Class
Switching hysteresis
Assured operating distanc...
Assured release distance ...
Distance s, actuator
Operating distance
Category
Mission time
Number of switching cycle...
PFHD
Performance Level
Diagnostic Coverage (DC)
For the approval acc. to ...
Repeat accuracy R
Rated conditional short-c...
Rated impulse withstand v...
Discrepancy time
Rated insulation voltage ...
Switching load
Switching current
Utilization category acc....
LED indicator
Input voltage
Input current
Output current
Type of output
Output voltage
Current via feedback loop
permissible resistance in...
Degree of contamination (...
EMC protection requiremen...
Connection cross-section
Dwell time
Fusing
Current consumption
Switching frequency
Operating voltage DC
Reaction time
Connection
Number of safety contacts
Mechanical life
Ambient temperature
Mounting method
Housing material
Mounting distance
Ready delay
Number of read heads
Degree of protection
Atmospheric humidity
Additional feature
Off-state current Ir
Test-pulse interval
Utilization category acc....
Test pulses
Turn-on time
Risk time according to EN...
Safety class
Extension of risk time ac...
Tightening torque
Installation orientation
Shock and vibration resis...
Cable ambient temperature...
Cable ambient temperature...
Dynamic bending radius
Material
Static bending radius
Selected product
Weight0.64815828 lb
SeriesCES-AZ evaluation
Product ClassSafety System
Switching hysteresismin.0,5 mm (These values ap...
Assured operating distance Saomin.10 mm (These values app...
Assured release distance Sarmax.26 mm
Distance s, actuatormin.3 mm
Operating distance15 mm (These values apply f...
Category4 (This value is dependent...
Mission time20 y (This value is depend...
Number of switching cyclesmax.760000 1/Jahr
PFHD1.9 x 10⁻⁸ (This value is d...
Performance LevelPL e (This value is depende...
Diagnostic Coverage (DC)99 %
For the approval acc. to UL the following applies(Operation only with UL clas...
Repeat accuracy Rmax.10 %
Rated conditional short-circuit current100 A
Rated impulse withstand voltage Uimp4 kV
Discrepancy timemax.25 ms
Rated insulation voltage Ui250 V
Switching loadClass 2 max. 30 V AC / Class...
Switching current10 ... 6000 mA
Utilization category acc. to EN 60947-5-1230 V 2 A
LED indicatorStatus LED
Input voltage0 ... 2 V DC
Input current5 ... 8 ... 10 mA
Output currentmax.20 mA
Type of outputSemiconductor output, p-swit...
Output voltage0,8 x UB ... UB V DC
Current via feedback loop5 ... 8 ... 10 mA
permissible resistance in feedback loopmax.600 Ω
Degree of contamination (external, according to EN 60947-1)2
EMC protection requirementsIn acc. with EN 60947-5-3
Connection cross-section0,25 ... 2,5 mm²
Dwell timemin.3 s (The dwell time is ...
Fusing0,25 ... 8 A
Current consumption150 mA (Without taking into...
Switching frequencymax.0,25 Hz (In case of mon...
Operating voltage DC21 ... 24 ... 27 V DC Regu...
Reaction timemin.250 ms
ConnectionPlug-in connection terminals...
Number of safety contacts2 Relays with internally ...
Mechanical life10 x 10⁶
Ambient temperature-20 ... 55 °C
Mounting methodMounting rail 35mm according...
Housing materialPlastic PA6.6
Mounting distancemin.10 mm (If several evalu...
Ready delay10 ... 12 s (After the oper...
Number of read headsMax. 2 read heads can be con...
Degree of protectionIP20
Atmospheric humiditymax.80 % rH
Additional feature-
Off-state current Ir-
Test-pulse interval-
Utilization category acc. to EN 60947-5-2-
Test pulses-
Turn-on time-
Risk time according to EN 60947-5-3-
Safety class-
Extension of risk time according to EN 60947-5-3 per device-
Tightening torque-
Installation orientation-
Shock and vibration resistance-
Cable ambient temperature (static)-
Cable ambient temperature (dynamic)-
Dynamic bending radius-
Material-
Static bending radius-
About the manufacturer

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.
Recently viewed products
Relevant products
FAQ
What is the price of 105140?
The price of 105140 on MQ Automation is $523.68. Order now.
Out if stock but available for backorder.
105140 Euchner - Evaluation unit CES-AZ-UES-02B (for 2 read heads)
Similar products from: Safety Proximity Sensors
What can I help you find today?