Product description

104966 Euchner - Read head CES-A-LSP-..., hard-wired encapsulated cable, 5 m, PVC

Product Details

  • Weight
    0.40344546 lb
  • Series
    CES read heads
  • Product Class
    Safety System
  • LED indicator
    White: valid actuator detected
  • Connecting cable
    PVC, length 5m, Ø 4.6 mm, with crimped ferrules
  • Cable length
    max.25 m
  • Degree of protection
    IP67
  • Tightening torque
    max.1 Nm
  • Installation orientation
    Any
  • Power supply
    Via evaluation unit
  • Weight
    0,02 kg ((Without connection cable))
  • Housing material
    PA6 GF30
  • Method of operation
    Inductive
  • Connection
    Hard-wired encapsulated connection cable
  • Ambient temperature
    -25 ... 70 °C

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 104966 on MQ Automation is $135.81. Order now.


About the product

Optimized for aluminum profile mounting;LED for indicating the door position;Hard-wired encapsulated cable made of PVC;Cable length 5 m


This item can ship in 3-5 days!

Manufacturer warranty

104966 Euchner

$135.81

Your price can be lower.
Log in or Create account to check your discount

Stock:

32

Select Qty:

$135.81

$135.81 each

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 104966 with other products

Weight

Series

Product Class

LED indicator

Connecting cable

Cable length

Degree of protection

Tightening torque

Installation orientation

Power supply

Housing material

Method of operation

Connection

Ambient temperature

Switching hysteresis

Assured operating distanc...

Assured release distance ...

PFHD

Operating distance

Mission time

Performance Level

Category

For the approval acc. to ...

Repeat accuracy R

Discrepancy time

Off-state current Ir

Utilization category acc....

Rated conditional short-c...

Test pulses

Test-pulse interval

Output voltage

Switching current

Turn-on time

Risk time according to EN...

Type of output

Fusing

Rated impulse withstand v...

Rated insulation voltage ...

Degree of contamination (...

Safety class

EMC protection requiremen...

Extension of risk time ac...

Current consumption

Mounting distance

Operating voltage DC

Switching frequency

Ready delay

Cable ambient temperature...

Mounting method

Static bending radius

Shock and vibration resis...

Cable ambient temperature...

Dynamic bending radius

Selected product

104966
32 in stock
104966
Euchner

104966 Euchner - Read head CES-A-LSP-..., hard-wired encapsulated cable, 5 m, PVC

Weight0.40344546 lb

SeriesCES read heads

Product ClassSafety System

LED indicatorWhite: valid actuator detect...

Connecting cablePVC, length 5m, Ø 4.6 mm, wi...

Cable lengthmax.25 m

Degree of protectionIP67

Tightening torquemax.1 Nm

Installation orientationAny

Power supplyVia evaluation unit

Housing materialPA6 GF30

Method of operationInductive

ConnectionHard-wired encapsulated conn...

Ambient temperature-25 ... 70 °C

Switching hysteresis-

Assured operating distance Sao-

Assured release distance Sar-

PFHD-

Operating distance-

Mission time-

Performance Level-

Category-

For the approval acc. to UL the following applies-

Repeat accuracy R-

Discrepancy time-

Off-state current Ir-

Utilization category acc. to EN 60947-5-2-

Rated conditional short-circuit current-

Test pulses-

Test-pulse interval-

Output voltage-

Switching current-

Turn-on time-

Risk time according to EN 60947-5-3-

Type of output-

Fusing-

Rated impulse withstand voltage Uimp-

Rated insulation voltage Ui-

Degree of contamination (external, according to EN 60947-1)-

Safety class-

EMC protection requirements-

Extension of risk time according to EN 60947-5-3 per device-

Current consumption-

Mounting distance-

Operating voltage DC-

Switching frequency-

Ready delay-

Cable ambient temperature (dynamic)-

Mounting method-

Static bending radius-

Shock and vibration resistance-

Cable ambient temperature (static)-

Dynamic bending radius-

105748
2 in stock
105748
Euchner

105748 Euchner - Non-contact safety switch CES-AR-CL2-... , plug connector M12, PUR

Weight0.29100984 lb

SeriesCES-AR

Product ClassSafety System

LED indicator-

Connecting cable-

Cable length-

Degree of protectionIP67

Tightening torquemax.1 Nm

Installation orientationAny

Power supply-

Housing materialPlastic, PBT

Method of operation-

ConnectionConnection cable PUR, length...

Ambient temperature-

Switching hysteresismin.1 mm

Assured operating distance Saomin.14 mm

Assured release distance Sarmax.60 mm

PFHD1.9 x 10⁻⁹

Operating distance19 mm

Mission time20

Performance LevelPL e

Category4

For the approval acc. to UL the following appliesOperation only with UL class...

Repeat accuracy R≤ 10

Discrepancy timemax.10 ms

Off-state current Irmax.0,25 mA

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Rated conditional short-circuit current100 A

Test pulsesmax.1 ms (Applies for a loa...

Test-pulse intervalmin.140 ms

Output voltage0,8 x UB ... UB V DC

Switching currentmax.50 mA

Turn-on timemax.400 ms

Risk time according to EN 60947-5-3max.260 ms

Type of outputp-switching, short circuit-p...

Fusing0,25 ... 8 A

Rated impulse withstand voltage Uimp1,5 kV

Rated insulation voltage Ui75 V

Degree of contamination (external, according to EN 60947-1)3

Safety classIII

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Current consumptionmax.50 mA (Without taking i...

Mounting distancemin.120 mm

Operating voltage DC24 V DC 15% ... 15% Regu...

Switching frequencymax.1 Hz

Ready delay10 s

Cable ambient temperature (dynamic)-25 ... 65 °C

Mounting methodSurface mounting on metal

Static bending radius5 x cable diameter

Shock and vibration resistanceIn acc. with EN 60947-5-3

Cable ambient temperature (static)-25 ... 65 °C

Dynamic bending radius10 x cable diameter

105602
3 in stock
105602
Euchner

105602 Euchner - Non-contact safety switch CES-AP-CL2-..., flying lead, PVC

Weight0.52029032 lb

SeriesCES-AP

Product ClassSafety System

LED indicator-

Connecting cable-

Cable length-

Degree of protectionIP67, IP69K

Tightening torquemax.1 Nm

Installation orientationAny

Power supply-

Housing materialPlastic, PBT

Method of operation-

Connectionconnection cable PVC, length...

Ambient temperature-

Switching hysteresismin.1 mm

Assured operating distance Saomin.14 mm

Assured release distance Sarmax.60 mm

PFHD1.8 x 10⁻⁹

Operating distance19 mm

Mission time20

Performance LevelPL e

Category4

For the approval acc. to UL the following appliesOperation only with UL class...

Repeat accuracy R≤ 10

Discrepancy timemax.10 ms

Off-state current Irmax.0,25 mA

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Rated conditional short-circuit current100 A

Test pulsesmax.0,3 ms (Applies for a l...

Test-pulse intervalmin.100 ms

Output voltage0,8 x UB ... UB V DC

Switching currentmax.50 mA

Turn-on timemax.300 ms

Risk time according to EN 60947-5-3max.260 ms

Type of outputp-switching, short circuit-p...

Fusing0,25 ... 8 A

Rated impulse withstand voltage Uimp1,5 kV

Rated insulation voltage Ui75 V

Degree of contamination (external, according to EN 60947-1)3

Safety classIII

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Extension of risk time according to EN 60947-5-3 per device-

Current consumptionmax.30 mA (Without taking i...

Mounting distancemin.400 mm

Operating voltage DC24 V DC 15% ... 15% Regu...

Switching frequencymax.1 Hz

Ready delay0,5 s

Cable ambient temperature (dynamic)0 ... 65 °C

Mounting methodSurface mounting on metal

Static bending radius5 x cable diameter

Shock and vibration resistanceIn acc. with EN 60947-5-3

Cable ambient temperature (static)-40 ... 65 °C

Dynamic bending radius10 x cable diameter

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

FAQ

What is the price of 104966?
The price of 104966 on MQ Automation is $135.81. Order now.

Out if stock but available for backorder.

104966 Euchner - Read head CES-A-LSP-..., hard-wired encapsulated cable, 5 m, PVC

What can I help you find today?

Recommended parts