104770 Euchner Safety Proximity Sensors

104770 on MQ Automation
Euchner
  • 104770
  • 104770
  • 104770

Part#:104770

Alt. Part#:CES-AZ-AES-01B

Manufacturer:Euchner

Category:Safety Proximity Sensors

Product Lifecycle:Active

83 in stock

Mar 15, 2025

Product description

104770 Euchner - Evaluation unit CES-AZ-AES-01B (for 1 read head)

Product Details

  • Weight
    0.50926722 lb
  • Series
    CES-AZ evaluation
  • Product Class
    Safety System
  • Switching hysteresis
    min.0,1 mm (These values apply for surface installation of the read head in steel.)
  • Assured operating distance Sao
    min.3,5 mm (These values apply for surface installation of the read head in steel.)
  • Assured release distance Sar
    max.10 mm
  • Operating distance
    5 mm (These values apply for surface installation of the read head in steel.)
  • Distance s, actuator
    min.1,2 mm
  • Mission time
    20 y (This value is dependent on the number of switching cycles and the switching current.)
  • Number of switching cycles
    max.760000 1/Jahr
  • Diagnostic Coverage (DC)
    99 %
  • PFHD
    1.9 x 10⁻⁸ (This value is dependent on the number of switching cycles and the switching current.)
  • Performance Level
    PL e (This value is dependent on the number of switching cycles and the switching current.)
  • Category
    4 (This value is dependent on the number of switching cycles and the switching current.)
  • LED indicator
    Status LED
  • Repeat accuracy R
    max.10 %
  • For the approval acc. to UL the following applies
    (Operation only with UL class 2 power supply, or equivalent measure.)
  • Input voltage
    15 ... UB V DC
  • Input current
    5 ... 8 ... 10 mA
  • Output current
    max.20 mA
  • Output voltage
    0,8 x UB ... UB V DC
  • Rated conditional short-circuit current
    100 A
  • Switching load
    Class 2 max. 30 V AC / Class 2 max. 60 V DC; 120 V AC 3 A / 240 V AC 1.5 A
  • Discrepancy time
    max.25 ms
  • Rated insulation voltage Ui
    250 V
  • Switching current
    1 ... 300 mA
  • Utilization category acc. to EN 60947-5-1
    230 V 2 A
  • Type of output
    Relay contacts, floating
  • Rated impulse withstand voltage Uimp
    4 kV
  • Fusing
    0,25 ... 8 A
  • Connection cross-section
    0,25 ... 2,5 mm²
  • permissible resistance in feedback loop
    max.600 Ω
  • Operating voltage DC
    21 ... 24 ... 27 V DC Regulated, residual ripple < 5 %
  • Current consumption
    150 mA (Without taking into account the load currents on the monitoring outputs)
  • EMC protection requirements
    In acc. with EN 60947-5-3
  • Degree of contamination (external, according to EN 60947-1)
    2
  • Current via feedback loop
    5 ... 8 ... 10 mA
  • Mechanical life
    10 x 10⁶
  • Number of safety contacts
    2 Relays with internally monitored contacts
  • Connection
    Plug-in connection terminals, coded (Terminals not included)
  • Reaction time
    max.210 ms (Corresponds to the risk time according to EN 60947-5-3. This is the maximum switch-off delay for the safety outputs following removal of the actuator. In case of EMC interference in excess of the requirements in accordance with EN 60947-5-3,
  • Switching frequency
    max.0,25 Hz
  • Dwell time
    min.3 s (The dwell time is the time that the actuator must be inside or outside the operating distance.)
  • Ready delay
    10 ... 12 s (After the operating voltage is switched on, the relay outputs are switched off and the door monitoring output is set LOW during the ready delay. For the visual indication of the delay, the green STATE LED flashes at a frequency of approx. 15
  • Number of read heads
    1 read head can be connected
  • Weight
    0,2 kg
  • Housing material
    Plastic PA6.6
  • Mounting distance
    min.10 mm (If several evaluation units are mounted side by side in a control cabinet without air circulation (e.g. fan), a minimum distance of 10 mm must be maintained between the evaluation units. The distance enables heat from the evaluation unit to di
  • Degree of protection
    IP20
  • Mounting method
    Mounting rail 35mm according to DIN EN 60715 TH35
  • Atmospheric humidity
    max.80 % rH
  • Ambient temperature
    -20 ... 55 °C

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 104770 on MQ Automation is $451.58. Order now.


About the product

1 read head can be connected;2 safety outputs (relay contacts with 2 internally connected NO contacts per output);Start button and feedback loop can be connected;Unicode;Plug-in connection terminals;Category 4 / PL e according to EN ISO 13849-1


This item can ship in 3-5 days!

Manufacturer warranty

104770 Euchner

$451.58

Your price can be lower.
Log in or Create account to check your discount

Stock:

83

Select Qty:

$451.58

$451.58 each

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 104770 with other products

Weight

Series

Product Class

Switching hysteresis

Assured operating distanc...

Assured release distance ...

Operating distance

Distance s, actuator

Mission time

Number of switching cycle...

Diagnostic Coverage (DC)

PFHD

Performance Level

Category

LED indicator

Repeat accuracy R

For the approval acc. to ...

Input voltage

Input current

Output current

Output voltage

Rated conditional short-c...

Switching load

Discrepancy time

Rated insulation voltage ...

Switching current

Utilization category acc....

Type of output

Rated impulse withstand v...

Fusing

Connection cross-section

permissible resistance in...

Operating voltage DC

Current consumption

EMC protection requiremen...

Degree of contamination (...

Current via feedback loop

Mechanical life

Number of safety contacts

Connection

Reaction time

Switching frequency

Dwell time

Ready delay

Number of read heads

Housing material

Mounting distance

Degree of protection

Mounting method

Atmospheric humidity

Ambient temperature

Off-state current Ir

Utilization category acc....

Test pulses

Test-pulse interval

Turn-on time

Risk time according to EN...

Safety class

Extension of risk time ac...

Tightening torque

Installation orientation

Cable ambient temperature...

Static bending radius

Shock and vibration resis...

Cable ambient temperature...

Dynamic bending radius

Selected product

104770
83 in stock
104770
Euchner

104770 Euchner - Evaluation unit CES-AZ-AES-01B (for 1 read head)

Weight0.50926722 lb

SeriesCES-AZ evaluation

Product ClassSafety System

Switching hysteresismin.0,1 mm (These values ap...

Assured operating distance Saomin.3,5 mm (These values ap...

Assured release distance Sarmax.10 mm

Operating distance5 mm (These values apply fo...

Distance s, actuatormin.1,2 mm

Mission time20 y (This value is depend...

Number of switching cyclesmax.760000 1/Jahr

Diagnostic Coverage (DC)99 %

PFHD1.9 x 10⁻⁸ (This value is d...

Performance LevelPL e (This value is depende...

Category4 (This value is dependent...

LED indicatorStatus LED

Repeat accuracy Rmax.10 %

For the approval acc. to UL the following applies(Operation only with UL clas...

Input voltage15 ... UB V DC

Input current5 ... 8 ... 10 mA

Output currentmax.20 mA

Output voltage0,8 x UB ... UB V DC

Rated conditional short-circuit current100 A

Switching loadClass 2 max. 30 V AC / Class...

Discrepancy timemax.25 ms

Rated insulation voltage Ui250 V

Switching current1 ... 300 mA

Utilization category acc. to EN 60947-5-1230 V 2 A

Type of outputRelay contacts, floating

Rated impulse withstand voltage Uimp4 kV

Fusing0,25 ... 8 A

Connection cross-section0,25 ... 2,5 mm²

permissible resistance in feedback loopmax.600 Ω

Operating voltage DC21 ... 24 ... 27 V DC Regu...

Current consumption150 mA (Without taking into...

EMC protection requirementsIn acc. with EN 60947-5-3

Degree of contamination (external, according to EN 60947-1)2

Current via feedback loop5 ... 8 ... 10 mA

Mechanical life10 x 10⁶

Number of safety contacts2 Relays with internally ...

ConnectionPlug-in connection terminals...

Reaction timemax.210 ms (Corresponds to ...

Switching frequencymax.0,25 Hz

Dwell timemin.3 s (The dwell time is ...

Ready delay10 ... 12 s (After the oper...

Number of read heads1 read head can be connected

Housing materialPlastic PA6.6

Mounting distancemin.10 mm (If several evalu...

Degree of protectionIP20

Mounting methodMounting rail 35mm according...

Atmospheric humiditymax.80 % rH

Ambient temperature-20 ... 55 °C

Off-state current Ir-

Utilization category acc. to EN 60947-5-2-

Test pulses-

Test-pulse interval-

Turn-on time-

Risk time according to EN 60947-5-3-

Safety class-

Extension of risk time according to EN 60947-5-3 per device-

Tightening torque-

Installation orientation-

Cable ambient temperature (dynamic)-

Static bending radius-

Shock and vibration resistance-

Cable ambient temperature (static)-

Dynamic bending radius-

105748
2 in stock
105748
Euchner

105748 Euchner - Non-contact safety switch CES-AR-CL2-... , plug connector M12, PUR

Weight0.29100984 lb

SeriesCES-AR

Product ClassSafety System

Switching hysteresismin.1 mm

Assured operating distance Saomin.14 mm

Assured release distance Sarmax.60 mm

Operating distance19 mm

Distance s, actuator-

Mission time20

Number of switching cycles-

Diagnostic Coverage (DC)-

PFHD1.9 x 10⁻⁹

Performance LevelPL e

Category4

LED indicator-

Repeat accuracy R≤ 10

For the approval acc. to UL the following appliesOperation only with UL class...

Input voltage-

Input current-

Output current-

Output voltage0,8 x UB ... UB V DC

Rated conditional short-circuit current100 A

Switching load-

Discrepancy timemax.10 ms

Rated insulation voltage Ui75 V

Switching currentmax.50 mA

Utilization category acc. to EN 60947-5-1-

Type of outputp-switching, short circuit-p...

Rated impulse withstand voltage Uimp1,5 kV

Fusing0,25 ... 8 A

Connection cross-section-

permissible resistance in feedback loop-

Operating voltage DC24 V DC 15% ... 15% Regu...

Current consumptionmax.50 mA (Without taking i...

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Degree of contamination (external, according to EN 60947-1)3

Current via feedback loop-

Mechanical life-

Number of safety contacts-

ConnectionConnection cable PUR, length...

Reaction time-

Switching frequencymax.1 Hz

Dwell time-

Ready delay10 s

Number of read heads-

Housing materialPlastic, PBT

Mounting distancemin.120 mm

Degree of protectionIP67

Mounting methodSurface mounting on metal

Atmospheric humidity-

Ambient temperature-

Off-state current Irmax.0,25 mA

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Test pulsesmax.1 ms (Applies for a loa...

Test-pulse intervalmin.140 ms

Turn-on timemax.400 ms

Risk time according to EN 60947-5-3max.260 ms

Safety classIII

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Tightening torquemax.1 Nm

Installation orientationAny

Cable ambient temperature (dynamic)-25 ... 65 °C

Static bending radius5 x cable diameter

Shock and vibration resistanceIn acc. with EN 60947-5-3

Cable ambient temperature (static)-25 ... 65 °C

Dynamic bending radius10 x cable diameter

105602
3 in stock
105602
Euchner

105602 Euchner - Non-contact safety switch CES-AP-CL2-..., flying lead, PVC

Weight0.52029032 lb

SeriesCES-AP

Product ClassSafety System

Switching hysteresismin.1 mm

Assured operating distance Saomin.14 mm

Assured release distance Sarmax.60 mm

Operating distance19 mm

Distance s, actuator-

Mission time20

Number of switching cycles-

Diagnostic Coverage (DC)-

PFHD1.8 x 10⁻⁹

Performance LevelPL e

Category4

LED indicator-

Repeat accuracy R≤ 10

For the approval acc. to UL the following appliesOperation only with UL class...

Input voltage-

Input current-

Output current-

Output voltage0,8 x UB ... UB V DC

Rated conditional short-circuit current100 A

Switching load-

Discrepancy timemax.10 ms

Rated insulation voltage Ui75 V

Switching currentmax.50 mA

Utilization category acc. to EN 60947-5-1-

Type of outputp-switching, short circuit-p...

Rated impulse withstand voltage Uimp1,5 kV

Fusing0,25 ... 8 A

Connection cross-section-

permissible resistance in feedback loop-

Operating voltage DC24 V DC 15% ... 15% Regu...

Current consumptionmax.30 mA (Without taking i...

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Degree of contamination (external, according to EN 60947-1)3

Current via feedback loop-

Mechanical life-

Number of safety contacts-

Connectionconnection cable PVC, length...

Reaction time-

Switching frequencymax.1 Hz

Dwell time-

Ready delay0,5 s

Number of read heads-

Housing materialPlastic, PBT

Mounting distancemin.400 mm

Degree of protectionIP67, IP69K

Mounting methodSurface mounting on metal

Atmospheric humidity-

Ambient temperature-

Off-state current Irmax.0,25 mA

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Test pulsesmax.0,3 ms (Applies for a l...

Test-pulse intervalmin.100 ms

Turn-on timemax.300 ms

Risk time according to EN 60947-5-3max.260 ms

Safety classIII

Extension of risk time according to EN 60947-5-3 per device-

Tightening torquemax.1 Nm

Installation orientationAny

Cable ambient temperature (dynamic)0 ... 65 °C

Static bending radius5 x cable diameter

Shock and vibration resistanceIn acc. with EN 60947-5-3

Cable ambient temperature (static)-40 ... 65 °C

Dynamic bending radius10 x cable diameter

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 104770?
The price of 104770 on MQ Automation is $451.58. Order now.

Out if stock but available for backorder.

104770 Euchner - Evaluation unit CES-AZ-AES-01B (for 1 read head)

What can I help you find today?

Recommended parts