104303 Euchner Safety Accessories

104303 on MQ Automation
Euchner
  • 104303
  • 104303
  • 104303

Part#:104303

Alt. Part#:MGB-L2-ARA-AA1A1-M-104303

Manufacturer:Euchner

Category:Safety Accessories

Product Lifecycle:Active

Product description

104303 Euchner - Locking module MGB-L2-ARA... (guard locking by solenoid force) without controls or indicators

Product Details

  • Weight
    2.03045502 lb
  • Series
    Spare parts
  • Product Class
    Accessories
  • Mission time
    20 y
  • PFHD
    3.7 x 10⁻⁹
  • Performance Level
    PL e
  • Category
    4
  • Product version number
    V4.0.0
  • Output current
    1 ... 200 mA
  • Type of output
    Semiconductor outputs, p-switching, short circuit-proof
  • Output voltage
    UB-2V ... UB V DC (Value at a switching current of 50mA without taking into account the cable lengths)
  • Test pulses
    max.1 ms
  • Test-pulse interval
    min.100 ms
  • Current consumption
    max.80 mA ((no load on outputs))
  • Operating voltage DC
    24 V DC -15% ... 10% ((Reverse polarity protected, regulated, residual ripple <5%, PELV))
  • Transponder coding
    Unicode
  • Risk time according to EN 60947-5-3
    max.350 ms
  • Discrepancy time
    max.10 ms
  • Safety class
    III
  • Connection cross-section
    0,13 ... 1,5 mm² ((AWG 24 ... AWG 16))
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Utilization category acc. to EN 60947-5-2
    24V 200mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)
  • Rated insulation voltage Ui
    30 V
  • Rated impulse withstand voltage Uimp
    1,5 kV
  • Ambient temperature
    -20 ... 55 °C
  • Locking force FZh
    2000 N
  • Weight
    0,75 kg
  • Guard locking principle
    Open-circuit current principle
  • Mechanical life
    0,1 x 10⁶
  • Degree of protection
    IP65
  • Installation orientation
    Any
  • Connection
    Cable entries M20x1.5
  • Switching frequency
    0,25 Hz
  • Housing material
    Reinforced plastic; die-cast zinc nickel-plated, stainless steel

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 104303 on MQ Automation is $878.46. Order now.


About the product

Guard locking with guard lock monitoring;Can be connected in series with other AR devices (e.g. CES-AR and CET-AR);With cable entry;Unicode


Manufacturer warranty

104303 Euchner

$878.46

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$878.46

$878.46 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 104303 with other products

Weight

Series

Product Class

Mission time

PFHD

Performance Level

Category

Product version number

Output current

Type of output

Output voltage

Test pulses

Test-pulse interval

Current consumption

Operating voltage DC

Transponder coding

Risk time according to EN...

Discrepancy time

Safety class

Connection cross-section

Degree of contamination (...

Utilization category acc....

Rated insulation voltage ...

Rated impulse withstand v...

Ambient temperature

Locking force FZh

Guard locking principle

Mechanical life

Degree of protection

Installation orientation

Connection

Switching frequency

Housing material

For the approval acc. to ...

Additional feature

Repeat accuracy R

Turn-on time

Off-state current Ir

Switching current

Switching load

Solenoid duty cycle

EMC protection requiremen...

Connection rating

Fusing

Solenoid operating voltag...

Actuating force

Extension of risk time ac...

Extraction force

Overtravel

Locking force Fmax

Approach speed

Retention force

Ready delay

Shock and vibration resis...

Switching hysteresis

Assured operating distanc...

Assured release distance ...

Operating distance

Rated conditional short-c...

Tightening torque

Mounting distance

Cable ambient temperature...

Mounting method

Static bending radius

Cable ambient temperature...

Dynamic bending radius

Selected product

104303
0 in stock
104303
Euchner

104303 Euchner - Locking module MGB-L2-ARA... (guard locking by solenoid force) without controls or ...

Weight2.03045502 lb

SeriesSpare parts

Product ClassAccessories

Mission time20 y

PFHD3.7 x 10⁻⁹

Performance LevelPL e

Category4

Product version numberV4.0.0

Output current1 ... 200 mA

Type of outputSemiconductor outputs, p-swi...

Output voltageUB-2V ... UB V DC (Value at...

Test pulsesmax.1 ms

Test-pulse intervalmin.100 ms

Current consumptionmax.80 mA ((no load on outp...

Operating voltage DC24 V DC -15% ... 10% ((Re...

Transponder codingUnicode

Risk time according to EN 60947-5-3max.350 ms

Discrepancy timemax.10 ms

Safety classIII

Connection cross-section0,13 ... 1,5 mm² ((AWG 24 ....

Degree of contamination (external, according to EN 60947-1)3

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Rated insulation voltage Ui30 V

Rated impulse withstand voltage Uimp1,5 kV

Ambient temperature-20 ... 55 °C

Locking force FZh2000 N

Guard locking principleOpen-circuit current princip...

Mechanical life0,1 x 10⁶

Degree of protectionIP65

Installation orientationAny

ConnectionCable entries M20x1.5

Switching frequency0,25 Hz

Housing materialReinforced plastic; die-cast...

For the approval acc. to UL the following applies-

Additional feature-

Repeat accuracy R-

Turn-on time-

Off-state current Ir-

Switching current-

Switching load-

Solenoid duty cycle-

EMC protection requirements-

Connection rating-

Fusing-

Solenoid operating voltage DC-

Actuating force-

Extension of risk time according to EN 60947-5-3 per device-

Extraction force-

Overtravel-

Locking force Fmax-

Approach speed-

Retention force-

Ready delay-

Shock and vibration resistance-

Switching hysteresis-

Assured operating distance Sao-

Assured release distance Sar-

Operating distance-

Rated conditional short-circuit current-

Tightening torque-

Mounting distance-

Cable ambient temperature (dynamic)-

Mounting method-

Static bending radius-

Cable ambient temperature (static)-

Dynamic bending radius-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

Mission time20 y

PFHD4.1 x 10 ⁻⁹

Performance LevelPL e

Category4

Product version number-

Output current-

Type of outputp-switching, short circuit-p...

Output voltage0,8xUB ... UB V DC

Test pulsesmax.1,0 ms (Applies for a l...

Test-pulse intervalmin.140 ms

Current consumption40 mA

Operating voltage DC24 V DC -15% ... 15% Rev...

Transponder coding-

Risk time according to EN 60947-5-3max.260 ms

Discrepancy timemax.10 ms In acc. with EN ...

Safety classIII

Connection cross-section-

Degree of contamination (external, according to EN 60947-1)3

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Rated insulation voltage Ui50 V

Rated impulse withstand voltage Uimp0,5 kV

Ambient temperature-20 ... +55 °C

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Guard locking principleClosed-circuit current princ...

Mechanical life1 x 10⁶

Degree of protectionIP67/IP69/IP69K (Screwed ti...

Installation orientationAny

Connection2 plug connectors M12, 5 and...

Switching frequencymax.0,5 Hz

Housing materialDie-cast zinc

For the approval acc. to UL the following appliesOperation only with UL class...

Additional featureEscape release actuated by p...

Repeat accuracy R10 %

Turn-on timemax.400 ms

Off-state current Irmax.0,25 mA

Switching current1 ... 50 mA

Switching load24V DC, class 2 (Alternativ...

Solenoid duty cycle100 %

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating6 W

Fusing0,25 ... 8 A

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Actuating force10 N

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Extraction force20 N

Overtravel5 mm

Locking force Fmax3900 N

Approach speedmax.20 m/min

Retention force20 N

Ready delay8 s

Shock and vibration resistanceIn acc. with EN 60947-5-3

Switching hysteresis-

Assured operating distance Sao-

Assured release distance Sar-

Operating distance-

Rated conditional short-circuit current-

Tightening torque-

Mounting distance-

Cable ambient temperature (dynamic)-

Mounting method-

Static bending radius-

Cable ambient temperature (static)-

Dynamic bending radius-

105748
2 in stock
105748
Euchner

105748 Euchner - Non-contact safety switch CES-AR-CL2-... , plug connector M12, PUR

Weight0.29100984 lb

SeriesCES-AR

Product ClassSafety System

Mission time20

PFHD1.9 x 10⁻⁹

Performance LevelPL e

Category4

Product version number-

Output current-

Type of outputp-switching, short circuit-p...

Output voltage0,8 x UB ... UB V DC

Test pulsesmax.1 ms (Applies for a loa...

Test-pulse intervalmin.140 ms

Current consumptionmax.50 mA (Without taking i...

Operating voltage DC24 V DC 15% ... 15% Regu...

Transponder coding-

Risk time according to EN 60947-5-3max.260 ms

Discrepancy timemax.10 ms

Safety classIII

Connection cross-section-

Degree of contamination (external, according to EN 60947-1)3

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Rated insulation voltage Ui75 V

Rated impulse withstand voltage Uimp1,5 kV

Ambient temperature-

Locking force FZh-

Guard locking principle-

Mechanical life-

Degree of protectionIP67

Installation orientationAny

ConnectionConnection cable PUR, length...

Switching frequencymax.1 Hz

Housing materialPlastic, PBT

For the approval acc. to UL the following appliesOperation only with UL class...

Additional feature-

Repeat accuracy R≤ 10

Turn-on timemax.400 ms

Off-state current Irmax.0,25 mA

Switching currentmax.50 mA

Switching load-

Solenoid duty cycle-

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating-

Fusing0,25 ... 8 A

Solenoid operating voltage DC-

Actuating force-

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Extraction force-

Overtravel-

Locking force Fmax-

Approach speed-

Retention force-

Ready delay10 s

Shock and vibration resistanceIn acc. with EN 60947-5-3

Switching hysteresismin.1 mm

Assured operating distance Saomin.14 mm

Assured release distance Sarmax.60 mm

Operating distance19 mm

Rated conditional short-circuit current100 A

Tightening torquemax.1 Nm

Mounting distancemin.120 mm

Cable ambient temperature (dynamic)-25 ... 65 °C

Mounting methodSurface mounting on metal

Static bending radius5 x cable diameter

Cable ambient temperature (static)-25 ... 65 °C

Dynamic bending radius10 x cable diameter

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 104303?
The price of 104303 on MQ Automation is $878.46. Order now.

Out if stock but available for backorder.

104303 Euchner - Locking module MGB-L2-ARA... (guard locking by solenoid force) without controls or indicators

What can I help you find today?

Recommended parts