Product description

103302 Euchner - AS-I PROFIBUS-GATEWAY WITH MONITOR

Product Details

  • Weight
    2.114595 lb
  • SIL CL
    3
  • Mission time
    20 y
  • PFHD
    5.36 x 10⁻⁹
  • Category
    4
  • Performance Level
    PL e
  • In compliance with
    EN 61 000-6-2, EN 61 000-6-4, EN 62 061, IEC 61 508, EN ISO 13 849-1
  • Peripheral equipment
    Decentralized peripheral equipment mapping of the AS-i slaves as I/O process data in the PROFIBUS; complete diagnostics and configuration via PROFIBUS DP master
  • Data rate
    9,6 ... 12000 kbit/s
  • Data interface
    PROFIBUS according to EN 50 170-3
  • Housing material
    Stainless steel
  • Type of output
    Output switching elements, output circuits 1, 2, 3 and 4
  • Card slot
    Yes (Memory card to store the configuration data)
  • Type of input
    Feedback loop/start
  • ASi cycle time
    150 µs 150 x (number of slaves + 2)
  • Switch-on delay
    max.10 s
  • Response delay
    max.40 ms
  • Connection rating
    9 W
  • Connection cross-section
    2x (0.5...1.5) mm²
  • Ambient temperature
    0 ... 55 °C
  • Number of outputs
    4
  • Number of masters
    2
  • Rated insulation voltage Ui
    500 V
  • ASi operating current
    max.300 mA
  • LED indicator
    LED power, power supply ON
  • ASi voltage
    30 V
  • Number of inputs
    4
  • Number of OSSDs
    16 (4 fed out)
  • Degree of protection
    IP20
  • Mounting method
    Mounting rail 35mm according to DIN EN 60715TH35
  • Weight
    0,8 kg
  • permissible shock and vibration load
    According to EN 61 131-2

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 103302 on MQ Automation is $4,049.67. Order now.


Manufacturer warranty

103302 Euchner

$4,049.67

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$4,049.67

$4,049.67 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 103302 with other products

Weight

SIL CL

Mission time

PFHD

Category

Performance Level

In compliance with

Peripheral equipment

Data rate

Data interface

Housing material

Type of output

Card slot

Type of input

ASi cycle time

Switch-on delay

Response delay

Connection rating

Connection cross-section

Ambient temperature

Number of outputs

Number of masters

Rated insulation voltage ...

ASi operating current

LED indicator

ASi voltage

Number of inputs

Number of OSSDs

Degree of protection

Mounting method

permissible shock and vib...

Series

Product Class

For the approval acc. to ...

Additional feature

Repeat accuracy R

Discrepancy time

Output voltage

Turn-on time

Off-state current Ir

Switching current

Switching load

Risk time according to EN...

Safety class

Degree of contamination (...

Solenoid duty cycle

EMC protection requiremen...

Rated impulse withstand v...

Fusing

Solenoid operating voltag...

Operating voltage DC

Utilization category acc....

Test pulses

Test-pulse interval

Actuating force

Extension of risk time ac...

Current consumption

Extraction force

Overtravel

Locking force Fmax

Approach speed

Retention force

Connection

Locking force FZh

Guard locking principle

Mechanical life

Switching frequency

Ready delay

Installation orientation

Shock and vibration resis...

B10D

Version

Operating current

Switching element

Detent mechanism

Operating voltage

Selected product

103302
0 in stock
103302
Euchner

103302 Euchner - AS-I PROFIBUS-GATEWAY WITH MONITOR

Weight2.114595 lb

SIL CL3

Mission time20 y

PFHD5.36 x 10⁻⁹

Category4

Performance LevelPL e

In compliance withEN 61 000-6-2, EN 61 000-6-4...

Peripheral equipmentDecentralized peripheral equ...

Data rate9,6 ... 12000 kbit/s

Data interfacePROFIBUS according to EN 50 ...

Housing materialStainless steel

Type of outputOutput switching elements, o...

Card slotYes (Memory card to store t...

Type of inputFeedback loop/start

ASi cycle time150 µs 150 x (number of s...

Switch-on delaymax.10 s

Response delaymax.40 ms

Connection rating9 W

Connection cross-section2x (0.5...1.5) mm²

Ambient temperature0 ... 55 °C

Number of outputs4

Number of masters2

Rated insulation voltage Ui500 V

ASi operating currentmax.300 mA

LED indicatorLED power, power supply ON

ASi voltage30 V

Number of inputs4

Number of OSSDs16 (4 fed out)

Degree of protectionIP20

Mounting methodMounting rail 35mm according...

permissible shock and vibration loadAccording to EN 61 131-2

Series-

Product Class-

For the approval acc. to UL the following applies-

Additional feature-

Repeat accuracy R-

Discrepancy time-

Output voltage-

Turn-on time-

Off-state current Ir-

Switching current-

Switching load-

Risk time according to EN 60947-5-3-

Safety class-

Degree of contamination (external, according to EN 60947-1)-

Solenoid duty cycle-

EMC protection requirements-

Rated impulse withstand voltage Uimp-

Fusing-

Solenoid operating voltage DC-

Operating voltage DC-

Utilization category acc. to EN 60947-5-2-

Test pulses-

Test-pulse interval-

Actuating force-

Extension of risk time according to EN 60947-5-3 per device-

Current consumption-

Extraction force-

Overtravel-

Locking force Fmax-

Approach speed-

Retention force-

Connection-

Locking force FZh-

Guard locking principle-

Mechanical life-

Switching frequency-

Ready delay-

Installation orientation-

Shock and vibration resistance-

B10D-

Version-

Operating current-

Switching element-

Detent mechanism-

Operating voltage-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SIL CL-

Mission time20 y

PFHD4.1 x 10 ⁻⁹

Category4

Performance LevelPL e

In compliance with-

Peripheral equipment-

Data rate-

Data interface-

Housing materialDie-cast zinc

Type of outputp-switching, short circuit-p...

Card slot-

Type of input-

ASi cycle time-

Switch-on delay-

Response delay-

Connection rating6 W

Connection cross-section-

Ambient temperature-20 ... +55 °C

Number of outputs-

Number of masters-

Rated insulation voltage Ui50 V

ASi operating current-

LED indicator-

ASi voltage-

Number of inputs-

Number of OSSDs-

Degree of protectionIP67/IP69/IP69K (Screwed ti...

Mounting method-

permissible shock and vibration load-

SeriesCTP-AR

Product ClassSafety System

For the approval acc. to UL the following appliesOperation only with UL class...

Additional featureEscape release actuated by p...

Repeat accuracy R10 %

Discrepancy timemax.10 ms In acc. with EN ...

Output voltage0,8xUB ... UB V DC

Turn-on timemax.400 ms

Off-state current Irmax.0,25 mA

Switching current1 ... 50 mA

Switching load24V DC, class 2 (Alternativ...

Risk time according to EN 60947-5-3max.260 ms

Safety classIII

Degree of contamination (external, according to EN 60947-1)3

Solenoid duty cycle100 %

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Rated impulse withstand voltage Uimp0,5 kV

Fusing0,25 ... 8 A

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Operating voltage DC24 V DC -15% ... 15% Rev...

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Test pulsesmax.1,0 ms (Applies for a l...

Test-pulse intervalmin.140 ms

Actuating force10 N

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Current consumption40 mA

Extraction force20 N

Overtravel5 mm

Locking force Fmax3900 N

Approach speedmax.20 m/min

Retention force20 N

Connection2 plug connectors M12, 5 and...

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Guard locking principleClosed-circuit current princ...

Mechanical life1 x 10⁶

Switching frequencymax.0,5 Hz

Ready delay8 s

Installation orientationAny

Shock and vibration resistanceIn acc. with EN 60947-5-3

B10D-

Version-

Operating current-

Switching element-

Detent mechanism-

Operating voltage-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

SIL CL-

Mission time20 y

PFHD4.1 x 10 ⁻⁹

Category4

Performance LevelPL e

In compliance with-

Peripheral equipment-

Data rate-

Data interface-

Housing materialFiber glass reinforced therm...

Type of output2 semiconductor outputs, p-s...

Card slot-

Type of input-

ASi cycle time-

Switch-on delay-

Response delay-

Connection rating1 W

Connection cross-section-

Ambient temperature-20 ... +55 °C

Number of outputs-

Number of masters-

Rated insulation voltage Ui50 V

ASi operating current-

LED indicator-

ASi voltage-

Number of inputs-

Number of OSSDs-

Degree of protectionIP65 (Screwed tight plug co...

Mounting method-

permissible shock and vibration load-

SeriesMGBS-P-I-AP

Product ClassSafety System

For the approval acc. to UL the following appliesOperation only with UL class...

Additional feature-

Repeat accuracy R10 %

Discrepancy timemax.10 ms In acc. with EN ...

Output voltage0 ... 1 V DC

Turn-on timemax.400 ms

Off-state current Irmax.0,25 mA

Switching current1 ... 150 mA

Switching load24V DC, class 2 (Alternativ...

Risk time according to EN 60947-5-3-

Safety classIII

Degree of contamination (external, according to EN 60947-1)3

Solenoid duty cycle-

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Rated impulse withstand voltage Uimp0,5 kV

Fusing0,25 ... 8 A

Solenoid operating voltage DC-

Operating voltage DC24 V DC -15% ... 15% Rev...

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Test pulsesmax.0,3 ms (Applies for a l...

Test-pulse intervalmin.100 ms

Actuating force10 N

Extension of risk time according to EN 60947-5-3 per device-

Current consumption40 mA

Extraction force20 N

Overtravel5 mm

Locking force Fmax-

Approach speedmax.20 m/min

Retention force-

Connection2 plug connectors M12, 5-pin

Locking force FZh-

Guard locking principle-

Mechanical life1 x 10⁶

Switching frequencymax.0,5 Hz

Ready delaymax.1 s

Installation orientationDoor hinge DIN right

Shock and vibration resistanceIn acc. with EN 60947-5-3

B10D0,13 x 10⁶

VersionEmergency stop

Operating current1 ... 100 mA

Switching element2 pos. driven NC

Detent mechanismSnap-in bolt

Operating voltage5 ... 24 V

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

FAQ

What is the price of 103302?
The price of 103302 on MQ Automation is $4,049.67. Order now.

Out if stock but available for backorder.

103302 Euchner - AS-I PROFIBUS-GATEWAY WITH MONITOR

What can I help you find today?

Recommended parts