100401 Euchner Electronic Key Systems

100401 on MQ Automation
Euchner
  • 100401
  • 100401
  • 100401

Part#:100401

Alt. Part#:EKS-A-IEX-G01-ST02/03

Manufacturer:Euchner

Category:Electronic Key Systems

Product Lifecycle:Active

6 in stock

Mar 15, 2025

Product description

100401 Euchner - Electronic-Key adapter with Ethernet TCP/IP interface

Product Details

  • Weight
    0.41446856 lb
  • Series
    EKS
  • Product Class
    Electronic-Key-System
  • Data interface
    Ethernet (IEEE 802.3)
  • Data protocol
    TCP/IP
  • Data rate
    10/100 Mbit/s
  • Connecting cable
    Min.2x2 twisted pair copper cable shielded, min. Cat. 5
  • Current consumption
    max.150 mA
  • Operating voltage DC
    20 ... 24 ... 28 V DC
  • LED indicator
    Key in operating distance
  • Housing material
    PA6-GF30 gray
  • Installation orientation
    On the front
  • Mounting cut-out
    33x68 mm
  • Ambient temperature
    0 ... 55 °C
  • Degree of protection
    IP67
  • Connection
    Star topology wiring

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 100401 on MQ Automation is $1,360.12. Order now.


About the product

Electronic-Key adapter with TCP/IP interface in housing G01;Read/write system;Remote mounting;Electronic-Key adapter and electronics in one housing;Transfers the data from the Electronic-Key to a control system for processing;Connection to PC;Open communication commands at the lowest level;Connection to the user software possible via ActiveX® module under Windows®;Various options for address assignment, also using DIP switches;Very reliable retention of the Electronic-Key, even if there is heavy vibration;Degree of protection: IP65/IP67 (installed);LED indicator


This item can ship in 3-5 days!

Manufacturer warranty

100401 Euchner

$1,360.12

Your price can be lower.
Log in or Create account to check your discount

Stock:

6

Select Qty:

$1,360.12

$1,360.12 each

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 100401 with other products

Weight

Series

Product Class

Data interface

Data protocol

Data rate

Connecting cable

Current consumption

Operating voltage DC

LED indicator

Housing material

Installation orientation

Mounting cut-out

Ambient temperature

Degree of protection

Connection

Additional feature

Utilization category acc....

Utilization category acc....

Connection cross-section

Switching current

Mounting method

Switching voltage

Number of read heads

Switching hysteresis

Assured operating distanc...

Assured release distance ...

PFHD

Operating distance

Mission time

Performance Level

Category

For the approval acc. to ...

Repeat accuracy R

Discrepancy time

Off-state current Ir

Rated conditional short-c...

Test pulses

Test-pulse interval

Output voltage

Turn-on time

Risk time according to EN...

Type of output

Fusing

Rated impulse withstand v...

Rated insulation voltage ...

Degree of contamination (...

Safety class

EMC protection requiremen...

Extension of risk time ac...

Tightening torque

Mounting distance

Switching frequency

Ready delay

Cable ambient temperature...

Static bending radius

Shock and vibration resis...

Cable ambient temperature...

Dynamic bending radius

Selected product

100401
6 in stock
100401
Euchner

100401 Euchner - Electronic-Key adapter with Ethernet TCP/IP interface

Weight0.41446856 lb

SeriesEKS

Product ClassElectronic-Key-System

Data interfaceEthernet (IEEE 802.3)

Data protocolTCP/IP

Data rate10/100 Mbit/s

Connecting cableMin.2x2 twisted pair copper ...

Current consumptionmax.150 mA

Operating voltage DC20 ... 24 ... 28 V DC

LED indicatorKey in operating distance

Housing materialPA6-GF30 gray

Installation orientationOn the front

Mounting cut-out33x68 mm

Ambient temperature0 ... 55 °C

Degree of protectionIP67

ConnectionStar topology wiring

Additional feature-

Utilization category acc. to EN 60947-5-1-

Utilization category acc. to EN 60947-5-2-

Connection cross-section-

Switching current-

Mounting method-

Switching voltage-

Number of read heads-

Switching hysteresis-

Assured operating distance Sao-

Assured release distance Sar-

PFHD-

Operating distance-

Mission time-

Performance Level-

Category-

For the approval acc. to UL the following applies-

Repeat accuracy R-

Discrepancy time-

Off-state current Ir-

Rated conditional short-circuit current-

Test pulses-

Test-pulse interval-

Output voltage-

Turn-on time-

Risk time according to EN 60947-5-3-

Type of output-

Fusing-

Rated impulse withstand voltage Uimp-

Rated insulation voltage Ui-

Degree of contamination (external, according to EN 60947-1)-

Safety class-

EMC protection requirements-

Extension of risk time according to EN 60947-5-3 per device-

Tightening torque-

Mounting distance-

Switching frequency-

Ready delay-

Cable ambient temperature (dynamic)-

Static bending radius-

Shock and vibration resistance-

Cable ambient temperature (static)-

Dynamic bending radius-

113645
1 in stock
113645
Euchner

113645 Euchner - Interface adapter EKS Light FSA modular (supports all operating states)

Weight0.46517482 lb

SeriesEKS Light

Product ClassElectronic-Key-System

Data interface4-bit parallel plus strobe, ...

Data protocol-

Data rate-

Connecting cable-

Current consumptionmax.70 mA

Operating voltage DC9 ... 24 ... 28 V DC (For u...

LED indicatorOperational

Housing materialPA6.6 gray

Installation orientation-

Mounting cut-out-

Ambient temperature0 ... 55 °C

Degree of protection-

ConnectionPlug-in screw terminal

Additional feature35 Resistance in switched-...

Utilization category acc. to EN 60947-5-124V 50mA

Utilization category acc. to EN 60947-5-224V 50mA

Connection cross-section0,14 ... 2,5 mm²

Switching current1 ... 10 ... 50 mA High si...

Mounting methodMounting rail 35mm according...

Switching voltageU<sub>B</sub>-2 ... U<sub>B<...

Number of read headsmax.1

Switching hysteresis-

Assured operating distance Sao-

Assured release distance Sar-

PFHD-

Operating distance-

Mission time-

Performance Level-

Category-

For the approval acc. to UL the following applies-

Repeat accuracy R-

Discrepancy time-

Off-state current Ir-

Rated conditional short-circuit current-

Test pulses-

Test-pulse interval-

Output voltage-

Turn-on time-

Risk time according to EN 60947-5-3-

Type of output-

Fusing-

Rated impulse withstand voltage Uimp-

Rated insulation voltage Ui-

Degree of contamination (external, according to EN 60947-1)-

Safety class-

EMC protection requirements-

Extension of risk time according to EN 60947-5-3 per device-

Tightening torque-

Mounting distance-

Switching frequency-

Ready delay-

Cable ambient temperature (dynamic)-

Static bending radius-

Shock and vibration resistance-

Cable ambient temperature (static)-

Dynamic bending radius-

105748
2 in stock
105748
Euchner

105748 Euchner - Non-contact safety switch CES-AR-CL2-... , plug connector M12, PUR

Weight0.29100984 lb

SeriesCES-AR

Product ClassSafety System

Data interface-

Data protocol-

Data rate-

Connecting cable-

Current consumptionmax.50 mA (Without taking i...

Operating voltage DC24 V DC 15% ... 15% Regu...

LED indicator-

Housing materialPlastic, PBT

Installation orientationAny

Mounting cut-out-

Ambient temperature-

Degree of protectionIP67

ConnectionConnection cable PUR, length...

Additional feature-

Utilization category acc. to EN 60947-5-1-

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Connection cross-section-

Switching currentmax.50 mA

Mounting methodSurface mounting on metal

Switching voltage-

Number of read heads-

Switching hysteresismin.1 mm

Assured operating distance Saomin.14 mm

Assured release distance Sarmax.60 mm

PFHD1.9 x 10⁻⁹

Operating distance19 mm

Mission time20

Performance LevelPL e

Category4

For the approval acc. to UL the following appliesOperation only with UL class...

Repeat accuracy R≤ 10

Discrepancy timemax.10 ms

Off-state current Irmax.0,25 mA

Rated conditional short-circuit current100 A

Test pulsesmax.1 ms (Applies for a loa...

Test-pulse intervalmin.140 ms

Output voltage0,8 x UB ... UB V DC

Turn-on timemax.400 ms

Risk time according to EN 60947-5-3max.260 ms

Type of outputp-switching, short circuit-p...

Fusing0,25 ... 8 A

Rated impulse withstand voltage Uimp1,5 kV

Rated insulation voltage Ui75 V

Degree of contamination (external, according to EN 60947-1)3

Safety classIII

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Tightening torquemax.1 Nm

Mounting distancemin.120 mm

Switching frequencymax.1 Hz

Ready delay10 s

Cable ambient temperature (dynamic)-25 ... 65 °C

Static bending radius5 x cable diameter

Shock and vibration resistanceIn acc. with EN 60947-5-3

Cable ambient temperature (static)-25 ... 65 °C

Dynamic bending radius10 x cable diameter

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 100401?
The price of 100401 on MQ Automation is $1,360.12. Order now.

Out if stock but available for backorder.

100401 Euchner - Electronic-Key adapter with Ethernet TCP/IP interface

What can I help you find today?

Recommended parts