100194 Euchner Pendant Control Stations


Part#:100194
Alt. Part#:HBA-100194
Manufacturer:Euchner
Category:Pendant Control Stations
Product Lifecycle:Active
Mar 15, 2025
Product description
100194 Euchner - PENDANT STATION
Product Details
- Weight 2.75625 lb
- For the approval acc. to UL the following applies Operation only with UL class 2 power supply, or equivalent measures
- Switching element 1 NO contact each
- Position See data sheets
- Connecting cable 28x0.14mm² (Screened)
- Special features Labeled
- Version Membrane key
- Color -
- Breaking capacity (VA) max.0,25 VA
- Pulses per revolution 2x100
- Type of output RS422
- EMC protection requirements EN 61000-6-2, EN 61000-6-4
- Switching current max.100 mA (Common connection)
- Switching voltage max.15 V
- Utilization category acc. to EN 60947-5-1 30V DC / 1A
- Cable length 3,5 m (Extended)
- Detent positions per revolution 100 (Magnetic detent mechanism)
- Operating voltage DC 5 V DC -5% ... 5%
- Degree of protection 205-12 (On the front)
- Connection Plug connector (28-pin, metal version)
- Weight 1,3 kg
- Atmospheric humidity max.80 % rH
- Ambient temperature 0 ... 50 °C
- Shock and vibration resistance Acc. to EN 60068-2-27/-2-6
- Material Polycarbonate
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 100194 on MQ Automation is $2,168.21. Order now.
This item can ship in 3-5 days!
Manufacturer warranty
100194 Euchner
$2,168.21
Your price can be lower.
Log in or Create account to check your discount
Stock:
Select Qty:
$2,168.21
$2,168.21 each
Fast Shipping & Delivery
Secure Payment Processing
Manufacturer warranty
Got Questions? We've Got Answers!
Need more details?
Feel free to chat with us
Compare 100194 with other products
Weight
For the approval acc. to ...
Switching element
Position
Connecting cable
Special features
Version
Color
Breaking capacity (VA)
Pulses per revolution
Type of output
EMC protection requiremen...
Switching current
Switching voltage
Utilization category acc....
Cable length
Detent positions per revo...
Operating voltage DC
Degree of protection
Connection
Atmospheric humidity
Ambient temperature
Shock and vibration resis...
Material
Series
Product Class
B10D
Mission time
PFHD
Performance Level
Category
Operating current
Repeat accuracy R
Detent mechanism
Discrepancy time
Off-state current Ir
Operating voltage
Safety class
Turn-on time
Switching load
Output voltage
Degree of contamination (...
Rated insulation voltage ...
Rated impulse withstand v...
Connection rating
Utilization category acc....
Fusing
Current consumption
Overtravel
Test-pulse interval
Extraction force
Test pulses
Actuating force
Installation orientation
Mechanical life
Housing material
Approach speed
Switching frequency
Ready delay
Assured operating distanc...
Switching hysteresis
Assured release distance ...
Operating distance
Additional feature
Rated conditional short-c...
Risk time according to EN...
Extension of risk time ac...
Tightening torque
Mounting method
Mounting distance
Cable ambient temperature...
Cable ambient temperature...
Dynamic bending radius
Static bending radius
Selected product
Weight2.75625 lb
For the approval acc. to UL the following appliesOperation only with UL class...
Switching element1 NO contact each
PositionSee data sheets
Connecting cable28x0.14mm² (Screened)
Special featuresLabeled
VersionMembrane key
Color-
Breaking capacity (VA)max.0,25 VA
Pulses per revolution2x100
Type of outputRS422
EMC protection requirementsEN 61000-6-2, EN 61000-6-4
Switching currentmax.100 mA (Common connecti...
Switching voltagemax.15 V
Utilization category acc. to EN 60947-5-130V DC / 1A
Cable length3,5 m (Extended)
Detent positions per revolution100 (Magnetic detent mecha...
Operating voltage DC5 V DC -5% ... 5%
Degree of protection205-12 (On the front)
ConnectionPlug connector (28-pin, met...
Atmospheric humiditymax.80 % rH
Ambient temperature0 ... 50 °C
Shock and vibration resistanceAcc. to EN 60068-2-27/-2-6
MaterialPolycarbonate
Series-
Product Class-
B10D-
Mission time-
PFHD-
Performance Level-
Category-
Operating current-
Repeat accuracy R-
Detent mechanism-
Discrepancy time-
Off-state current Ir-
Operating voltage-
Safety class-
Turn-on time-
Switching load-
Output voltage-
Degree of contamination (external, according to EN 60947-1)-
Rated insulation voltage Ui-
Rated impulse withstand voltage Uimp-
Connection rating-
Utilization category acc. to EN 60947-5-2-
Fusing-
Current consumption-
Overtravel-
Test-pulse interval-
Extraction force-
Test pulses-
Actuating force-
Installation orientation-
Mechanical life-
Housing material-
Approach speed-
Switching frequency-
Ready delay-
Assured operating distance Sao-
Switching hysteresis-
Assured release distance Sar-
Operating distance-
Additional feature-
Rated conditional short-circuit current-
Risk time according to EN 60947-5-3-
Extension of risk time according to EN 60947-5-3 per device-
Tightening torque-
Mounting method-
Mounting distance-
Cable ambient temperature (static)-
Cable ambient temperature (dynamic)-
Dynamic bending radius-
Static bending radius-
About the manufacturer

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.
Recently viewed products
Relevant products
FAQ
What is the price of 100194?
The price of 100194 on MQ Automation is $2,168.21. Order now.
Out if stock but available for backorder.
100194 Euchner - PENDANT STATION
What can I help you find today?