Product description

099258 Euchner - Evaluation unit CMS-E-FR, 2 safety contacts, 1 auxiliary contact, 6 monitoring outputs, 1 feedback loop can be connected

Product Details

  • Weight
    0.76941238 lb
  • Series
    CMS
  • Product Class
    Safety System
  • Assured operating distance Sao
    min.6 mm (Figure only applies if there is no ferromagnetic material in the vicinity of the read head and the actuator.)
  • Assured release distance Sar
    max.14 mm (The assured switch-off distance sar corresponds to the reset distance.)
  • Number of switching cycles
    max.70000 1/Jahr
  • Center offset
    2,5 mm (Figure only applies if there is no ferromagnetic material in the vicinity of the read head and the actuator.)
  • PFHD
    2.5 x 10⁻⁸ (This value is dependent on the number of switching cycles and the switching current.)
  • Mission time
    20 y (This value is dependent on the number of switching cycles and the switching current.)
  • Performance Level
    PL e (This value is dependent on the number of switching cycles and the switching current.)
  • Category
    4 (This value is dependent on the number of switching cycles and the switching current.)
  • In compliance with
    EN ISO 13849-1: 2015; EN ISO 13849-2:2012; EN 50178: 1997; EN 60204-1: 2006/A1: 2009; EN ISO 13850: 2015; EN 14119: 2013; EN 6100-2-6: 2005; EN 6100-6-3: 2007/A1: 2011; EN 60947-5-3: 2013
  • Risk time according to EN 60947-5-3
    max.20 ms
  • Breaking capacity (VA)
    max.720 VA
  • Switching load
    Input: 24V AC/DC ; output: 30V AC, 24V DC
  • Utilization category acc. to EN 60947-5-1
    0.9A , 240V and 0.9A , 24V (Max. switching current per contact)
  • Switching current
    10 ... 3000 mA
  • Switching voltage
    max.240 V
  • Type of output
    Relay contacts, floating (2 NO contact pairs)
  • LED indicator
    1 indicator LED Power, 2 output LEDs and 6 status indicators for the read heads
  • Connection cross-section
    0,14 ... 2,5 mm²
  • Degree of contamination (external, according to EN 60947-1)
    2
  • Rated insulation voltage Ui
    250 V
  • Current consumption
    10 ... 120 mA
  • Fusing
    0,75 A Automatically resetting fuse PTC
  • Operating voltage
    24 V -10% ... +10% (All the electrical connections must either be isolated from the mains supply by a safety transformer according to EN 61558-2-6 with limited output voltage in the event of a fault, or by other equivalent isolation measures.)
  • Number of monitoring outputs
    6
  • Number of auxiliary contacts
    1
  • Number of safety contacts
    2
  • Housing material
    Polyamide PA6.6
  • Mounting method
    Mounting rail 35mm according to DIN EN 60715 TH35
  • Connection
    Connection terminals
  • Mechanical life
    10 x 10⁶
  • Ambient temperature
    0 ... 55 °C
  • Degree of protection
    Terminals IP20 / housing IP40
  • Weight
    0,3 kg

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 099258 on MQ Automation is $409.44. Order now.


About the product

Up to 6 read heads can be connected;2 safety contacts;1 auxiliary contact;6 monitoring outputs;1 feedback loop can be connected;Start automatic/monitored/not monitored


This item can ship in 3-5 days!

Manufacturer warranty

099258 Euchner

$409.44

Your price can be lower.
Log in or Create account to check your discount

Stock:

2

Select Qty:

$409.44

$409.44 each

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 099258 with other products

Weight

Series

Product Class

Assured operating distanc...

Assured release distance ...

Number of switching cycle...

Center offset

PFHD

Mission time

Performance Level

Category

In compliance with

Risk time according to EN...

Breaking capacity (VA)

Switching load

Utilization category acc....

Switching current

Switching voltage

Type of output

LED indicator

Connection cross-section

Degree of contamination (...

Rated insulation voltage ...

Current consumption

Fusing

Operating voltage

Number of monitoring outp...

Number of auxiliary conta...

Number of safety contacts

Housing material

Mounting method

Connection

Mechanical life

Ambient temperature

Degree of protection

Switching hysteresis

Operating distance

For the approval acc. to ...

Additional feature

Repeat accuracy R

Discrepancy time

Off-state current Ir

Rated conditional short-c...

Test-pulse interval

Utilization category acc....

Test pulses

Output voltage

Turn-on time

Safety class

EMC protection requiremen...

Rated impulse withstand v...

Operating voltage DC

Switching frequency

Extension of risk time ac...

Ready delay

Tightening torque

Installation orientation

Shock and vibration resis...

Mounting distance

Cable ambient temperature...

Cable ambient temperature...

Dynamic bending radius

Material

Static bending radius

Selected product

099258
2 in stock
099258
Euchner

099258 Euchner - Evaluation unit CMS-E-FR, 2 safety contacts, 1 auxiliary contact, 6 monitoring outp...

Weight0.76941238 lb

SeriesCMS

Product ClassSafety System

Assured operating distance Saomin.6 mm (Figure only appli...

Assured release distance Sarmax.14 mm (The assured swit...

Number of switching cyclesmax.70000 1/Jahr

Center offset2,5 mm (Figure only applies...

PFHD2.5 x 10⁻⁸ (This value is d...

Mission time20 y (This value is depend...

Performance LevelPL e (This value is depende...

Category4 (This value is dependent...

In compliance withEN ISO 13849-1: 2015; EN ISO...

Risk time according to EN 60947-5-3max.20 ms

Breaking capacity (VA)max.720 VA

Switching loadInput: 24V AC/DC ; output: ...

Utilization category acc. to EN 60947-5-10.9A , 240V and 0.9A , 24V ...

Switching current10 ... 3000 mA

Switching voltagemax.240 V

Type of outputRelay contacts, floating (2...

LED indicator1 indicator LED Power, 2 out...

Connection cross-section0,14 ... 2,5 mm²

Degree of contamination (external, according to EN 60947-1)2

Rated insulation voltage Ui250 V

Current consumption10 ... 120 mA

Fusing0,75 A Automatically rese...

Operating voltage24 V -10% ... +10% (All t...

Number of monitoring outputs6

Number of auxiliary contacts1

Number of safety contacts2

Housing materialPolyamide PA6.6

Mounting methodMounting rail 35mm according...

ConnectionConnection terminals

Mechanical life10 x 10⁶

Ambient temperature0 ... 55 °C

Degree of protectionTerminals IP20 / housing IP4...

Switching hysteresis-

Operating distance-

For the approval acc. to UL the following applies-

Additional feature-

Repeat accuracy R-

Discrepancy time-

Off-state current Ir-

Rated conditional short-circuit current-

Test-pulse interval-

Utilization category acc. to EN 60947-5-2-

Test pulses-

Output voltage-

Turn-on time-

Safety class-

EMC protection requirements-

Rated impulse withstand voltage Uimp-

Operating voltage DC-

Switching frequency-

Extension of risk time according to EN 60947-5-3 per device-

Ready delay-

Tightening torque-

Installation orientation-

Shock and vibration resistance-

Mounting distance-

Cable ambient temperature (static)-

Cable ambient temperature (dynamic)-

Dynamic bending radius-

Material-

Static bending radius-

119473
23 in stock
119473
Euchner

119473 Euchner - Non-contact safety switches CES-I-AR-.-C04-…, M12

Weight0.23589434 lb

SeriesCES-AR

Product ClassSafety System

Assured operating distance Sao6

Assured release distance Sarmax.60 mm

Number of switching cycles-

Center offset-

PFHD4.1 x 10⁻⁹

Mission time20

Performance LevelPL e

Category4

In compliance with-

Risk time according to EN 60947-5-3max.260 ms

Breaking capacity (VA)-

Switching load-

Utilization category acc. to EN 60947-5-1-

Switching currentmax.50 mA

Switching voltage-

Type of outputSemiconductor output, p-swit...

LED indicator-

Connection cross-section-

Degree of contamination (external, according to EN 60947-1)3

Rated insulation voltage Ui300 V

Current consumptionmax.35 mA (Without taking i...

Fusing0,25 ... 8 A

Operating voltage-

Number of monitoring outputs-

Number of auxiliary contacts-

Number of safety contacts-

Housing materialPlastic, PBT

Mounting methodSurface mounting on metal

ConnectionConnection cable PUR, length...

Mechanical life-

Ambient temperature-

Degree of protectionIP67

Switching hysteresismin.1 mm

Operating distance11 mm

For the approval acc. to UL the following appliesOperation only with UL class...

Additional featureRubber support included

Repeat accuracy R≤ 10

Discrepancy timemax.10 ms

Off-state current Irmax.0,25 mA

Rated conditional short-circuit current100 A

Test-pulse intervalmin.140 ms

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Test pulsesmax.1,0 ms (Applies for a l...

Output voltage0,8 x UB ... UB V DC

Turn-on timemax.400 ms

Safety classIII

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Rated impulse withstand voltage Uimp1,5 kV

Operating voltage DC24 V DC 15% ... 15% Regu...

Switching frequencymax.1 Hz

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Ready delay10 s

Tightening torquemax.0,8 Nm

Installation orientationAny

Shock and vibration resistanceIn acc. with EN 60947-5-3

Mounting distancemin.80 mm

Cable ambient temperature (static)-25 ... 65 °C

Cable ambient temperature (dynamic)-25 ... 65 °C

Dynamic bending radius10 x cable diameter

MaterialNBR 80 ±5 Shore

Static bending radius5 x cable diameter

105748
2 in stock
105748
Euchner

105748 Euchner - Non-contact safety switch CES-AR-CL2-... , plug connector M12, PUR

Weight0.29100984 lb

SeriesCES-AR

Product ClassSafety System

Assured operating distance Saomin.14 mm

Assured release distance Sarmax.60 mm

Number of switching cycles-

Center offset-

PFHD1.9 x 10⁻⁹

Mission time20

Performance LevelPL e

Category4

In compliance with-

Risk time according to EN 60947-5-3max.260 ms

Breaking capacity (VA)-

Switching load-

Utilization category acc. to EN 60947-5-1-

Switching currentmax.50 mA

Switching voltage-

Type of outputp-switching, short circuit-p...

LED indicator-

Connection cross-section-

Degree of contamination (external, according to EN 60947-1)3

Rated insulation voltage Ui75 V

Current consumptionmax.50 mA (Without taking i...

Fusing0,25 ... 8 A

Operating voltage-

Number of monitoring outputs-

Number of auxiliary contacts-

Number of safety contacts-

Housing materialPlastic, PBT

Mounting methodSurface mounting on metal

ConnectionConnection cable PUR, length...

Mechanical life-

Ambient temperature-

Degree of protectionIP67

Switching hysteresismin.1 mm

Operating distance19 mm

For the approval acc. to UL the following appliesOperation only with UL class...

Additional feature-

Repeat accuracy R≤ 10

Discrepancy timemax.10 ms

Off-state current Irmax.0,25 mA

Rated conditional short-circuit current100 A

Test-pulse intervalmin.140 ms

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Test pulsesmax.1 ms (Applies for a loa...

Output voltage0,8 x UB ... UB V DC

Turn-on timemax.400 ms

Safety classIII

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Rated impulse withstand voltage Uimp1,5 kV

Operating voltage DC24 V DC 15% ... 15% Regu...

Switching frequencymax.1 Hz

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Ready delay10 s

Tightening torquemax.1 Nm

Installation orientationAny

Shock and vibration resistanceIn acc. with EN 60947-5-3

Mounting distancemin.120 mm

Cable ambient temperature (static)-25 ... 65 °C

Cable ambient temperature (dynamic)-25 ... 65 °C

Dynamic bending radius10 x cable diameter

Material-

Static bending radius5 x cable diameter

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 099258?
The price of 099258 on MQ Automation is $409.44. Order now.

Out if stock but available for backorder.

099258 Euchner - Evaluation unit CMS-E-FR, 2 safety contacts, 1 auxiliary contact, 6 monitoring outputs, 1 feedback loop can be connected

What can I help you find today?

Recommended parts