099258 Euchner Safety Accessories
Part#:099258
Alt. Part#:CMS-E-FR
Manufacturer:Euchner
Category:Safety Accessories
Product Lifecycle:Active
Mar 15, 2025
Product description
099258 Euchner - Evaluation unit CMS-E-FR, 2 safety contacts, 1 auxiliary contact, 6 monitoring outputs, 1 feedback loop can be connected
Product Details
- Weight 0.76941238 lb
- Series CMS
- Product Class Safety System
- Assured operating distance Sao min.6 mm (Figure only applies if there is no ferromagnetic material in the vicinity of the read head and the actuator.)
- Assured release distance Sar max.14 mm (The assured switch-off distance sar corresponds to the reset distance.)
- Number of switching cycles max.70000 1/Jahr
- Center offset 2,5 mm (Figure only applies if there is no ferromagnetic material in the vicinity of the read head and the actuator.)
- PFHD 2.5 x 10⁻⁸ (This value is dependent on the number of switching cycles and the switching current.)
- Mission time 20 y (This value is dependent on the number of switching cycles and the switching current.)
- Performance Level PL e (This value is dependent on the number of switching cycles and the switching current.)
- Category 4 (This value is dependent on the number of switching cycles and the switching current.)
- In compliance with EN ISO 13849-1: 2015; EN ISO 13849-2:2012; EN 50178: 1997; EN 60204-1: 2006/A1: 2009; EN ISO 13850: 2015; EN 14119: 2013; EN 6100-2-6: 2005; EN 6100-6-3: 2007/A1: 2011; EN 60947-5-3: 2013
- Risk time according to EN 60947-5-3 max.20 ms
- Breaking capacity (VA) max.720 VA
- Switching load Input: 24V AC/DC ; output: 30V AC, 24V DC
- Utilization category acc. to EN 60947-5-1 0.9A , 240V and 0.9A , 24V (Max. switching current per contact)
- Switching current 10 ... 3000 mA
- Switching voltage max.240 V
- Type of output Relay contacts, floating (2 NO contact pairs)
- LED indicator 1 indicator LED Power, 2 output LEDs and 6 status indicators for the read heads
- Connection cross-section 0,14 ... 2,5 mm²
- Degree of contamination (external, according to EN 60947-1) 2
- Rated insulation voltage Ui 250 V
- Current consumption 10 ... 120 mA
- Fusing 0,75 A Automatically resetting fuse PTC
- Operating voltage 24 V -10% ... +10% (All the electrical connections must either be isolated from the mains supply by a safety transformer according to EN 61558-2-6 with limited output voltage in the event of a fault, or by other equivalent isolation measures.)
- Number of monitoring outputs 6
- Number of auxiliary contacts 1
- Number of safety contacts 2
- Housing material Polyamide PA6.6
- Mounting method Mounting rail 35mm according to DIN EN 60715 TH35
- Connection Connection terminals
- Mechanical life 10 x 10⁶
- Ambient temperature 0 ... 55 °C
- Degree of protection Terminals IP20 / housing IP40
- Weight 0,3 kg
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 099258 on MQ Automation is $409.44. Order now.
About the product
Up to 6 read heads can be connected;2 safety contacts;1 auxiliary contact;6 monitoring outputs;1 feedback loop can be connected;Start automatic/monitored/not monitored
This item can ship in 3-5 days!
Manufacturer warranty
099258 Euchner
$409.44
Your price can be lower.
Log in or Create account to check your discount
Stock:
Select Qty:
$409.44
$409.44 each
Fast Shipping & Delivery
Secure Payment Processing
Manufacturer warranty
Got Questions? We've Got Answers!
Need more details?
Feel free to chat with us
Compare 099258 with other products
Weight
Series
Product Class
Assured operating distanc...
Assured release distance ...
Number of switching cycle...
Center offset
PFHD
Mission time
Performance Level
Category
In compliance with
Risk time according to EN...
Breaking capacity (VA)
Switching load
Utilization category acc....
Switching current
Switching voltage
Type of output
LED indicator
Connection cross-section
Degree of contamination (...
Rated insulation voltage ...
Current consumption
Fusing
Operating voltage
Number of monitoring outp...
Number of auxiliary conta...
Number of safety contacts
Housing material
Mounting method
Connection
Mechanical life
Ambient temperature
Degree of protection
Switching hysteresis
Operating distance
For the approval acc. to ...
Additional feature
Repeat accuracy R
Discrepancy time
Off-state current Ir
Rated conditional short-c...
Test-pulse interval
Utilization category acc....
Test pulses
Output voltage
Turn-on time
Safety class
EMC protection requiremen...
Rated impulse withstand v...
Operating voltage DC
Switching frequency
Extension of risk time ac...
Ready delay
Tightening torque
Installation orientation
Shock and vibration resis...
Mounting distance
Cable ambient temperature...
Cable ambient temperature...
Dynamic bending radius
Material
Static bending radius
Selected product

099258
Euchner
099258 Euchner - Evaluation unit CMS-E-FR, 2 safety contacts, 1 auxiliary contact, 6 monitoring outp...
Weight0.76941238 lb
SeriesCMS
Product ClassSafety System
Assured operating distance Saomin.6 mm (Figure only appli...
Assured release distance Sarmax.14 mm (The assured swit...
Number of switching cyclesmax.70000 1/Jahr
Center offset2,5 mm (Figure only applies...
PFHD2.5 x 10⁻⁸ (This value is d...
Mission time20 y (This value is depend...
Performance LevelPL e (This value is depende...
Category4 (This value is dependent...
In compliance withEN ISO 13849-1: 2015; EN ISO...
Risk time according to EN 60947-5-3max.20 ms
Breaking capacity (VA)max.720 VA
Switching loadInput: 24V AC/DC ; output: ...
Utilization category acc. to EN 60947-5-10.9A , 240V and 0.9A , 24V ...
Switching current10 ... 3000 mA
Switching voltagemax.240 V
Type of outputRelay contacts, floating (2...
LED indicator1 indicator LED Power, 2 out...
Connection cross-section0,14 ... 2,5 mm²
Degree of contamination (external, according to EN 60947-1)2
Rated insulation voltage Ui250 V
Current consumption10 ... 120 mA
Fusing0,75 A Automatically rese...
Operating voltage24 V -10% ... +10% (All t...
Number of monitoring outputs6
Number of auxiliary contacts1
Number of safety contacts2
Housing materialPolyamide PA6.6
Mounting methodMounting rail 35mm according...
ConnectionConnection terminals
Mechanical life10 x 10⁶
Ambient temperature0 ... 55 °C
Degree of protectionTerminals IP20 / housing IP4...
Switching hysteresis-
Operating distance-
For the approval acc. to UL the following applies-
Additional feature-
Repeat accuracy R-
Discrepancy time-
Off-state current Ir-
Rated conditional short-circuit current-
Test-pulse interval-
Utilization category acc. to EN 60947-5-2-
Test pulses-
Output voltage-
Turn-on time-
Safety class-
EMC protection requirements-
Rated impulse withstand voltage Uimp-
Operating voltage DC-
Switching frequency-
Extension of risk time according to EN 60947-5-3 per device-
Ready delay-
Tightening torque-
Installation orientation-
Shock and vibration resistance-
Mounting distance-
Cable ambient temperature (static)-
Cable ambient temperature (dynamic)-
Dynamic bending radius-
Material-
Static bending radius-
About the manufacturer

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.
Recently viewed products
Relevant products
FAQ
What is the price of 099258?
The price of 099258 on MQ Automation is $409.44. Order now.
Out if stock but available for backorder.
099258 Euchner - Evaluation unit CMS-E-FR, 2 safety contacts, 1 auxiliary contact, 6 monitoring outputs, 1 feedback loop can be connected
Similar products from: Safety Accessories
What can I help you find today?