099182 Euchner Safety Accessories
Part#:099182
Alt. Part#:CMS-E-ER
Manufacturer:Euchner
Category:Safety Accessories
Product Lifecycle:Active
Product description
099182 Euchner - Evaluation unit CMS-E-ER, 2 safety contacts, 1 auxiliary contact, 1 feedback loop can be connected
Product Details
- Weight 0.4960395 lb
- Series CMS
- Product Class Safety System
- Assured release distance Sar max.31 mm (The assured switch-off distance sar corresponds to the reset distance.)
- Assured operating distance Sao min.6 mm (Figure only applies if there is no ferromagnetic material in the vicinity of the read head and the actuator.)
- Center offset 2,5 mm (Figure only applies if there is no ferromagnetic material in the vicinity of the read head and the actuator.)
- Mission time 20 y (This value is dependent on the number of switching cycles and the switching current.)
- Number of switching cycles 70000 1/Jahr
- PFHD 1.0 x 10⁻⁷ (This value is dependent on the number of switching cycles and the switching current. This value applies to cables laid with protection. The following applies if cables are laid without protection and more than one door must be opened frequent
- Category 3 (This value is dependent on the number of switching cycles and the switching current.)
- In compliance with EN ISO 13849-1: 2015; EN ISO 13849-2:2012; EN 50178: 1997; EN 60204-1: 2006/A1: 2009; EN ISO 13850: 2015; EN 14119:2013; EN 6100-6-2: 2005; EN 6100-6-3: 2007/A1: 2011; EN 60947-5-3: 2013
- Performance Level PL d (This value is dependent on the number of switching cycles and the switching current. This value applies to cables laid with protection. The following applies if cables are laid without protection and more than one door must be opened frequently or
- Risk time according to EN 60947-5-3 max.20 ms
- Switching load Input: 24V AC/DC ; output: 30V AC, 24V DC
- Breaking capacity (VA) max.720 VA
- Utilization category acc. to EN 60947-5-1 0.9A , 240V and 0.9A , 24V (Max. switching current per contact)
- Switching current 10 ... 3000 mA
- Degree of contamination (external, according to EN 60947-1) 2
- Connection cross-section 0,14 ... 2,5 mm²
- Current consumption 10 ... 110 mA
- Operating voltage 24 V -10% ... +10% V (All the electrical connections must either be isolated from the mains supply by a safety transformer according to EN 61558-2-6 with limited output voltage in the event of a fault, or by other equivalent isolation measures.)
- Fusing 0,75 A Automatically resetting fuse PTC
- Rated insulation voltage Ui 250 V
- LED indicator 1 indicator LED Power (UB) and 2 status indicators for the read heads (K1/K2)
- Type of output Relay contacts, floating (2 NO contact pairs)
- Switching voltage max.240 V
- Number of auxiliary contacts 1
- Degree of protection Terminals IP20 / housing IP40
- Mechanical life 10 x 10⁶
- Number of safety contacts 2
- Housing material Polyamide PA6.6
- Ambient temperature 0 ... 55 °C
- Connection Connection terminals
- Mounting method Mounting rail 35mm according to DIN EN 60715 TH35
- Weight 0,22 kg
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 099182 on MQ Automation is $284.41. Order now.
About the product
Up to 30 read heads can be connected;2 safety contacts;1 auxiliary contact;1 feedback loop can be connected;Start automatic/monitored/not monitored
Manufacturer warranty
099182 Euchner
$284.41
Your price can be lower.
Log in or Create account to check your discount
Select Qty:
$284.41
$284.41 each
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Manufacturer warranty
Got Questions? We've Got Answers!
Need more details?
Feel free to chat with us
Compare 099182 with other products
Weight
Series
Product Class
Assured release distance ...
Assured operating distanc...
Center offset
Mission time
Number of switching cycle...
PFHD
Category
In compliance with
Performance Level
Risk time according to EN...
Switching load
Breaking capacity (VA)
Utilization category acc....
Switching current
Degree of contamination (...
Connection cross-section
Current consumption
Operating voltage
Fusing
Rated insulation voltage ...
LED indicator
Type of output
Switching voltage
Number of auxiliary conta...
Degree of protection
Mechanical life
Number of safety contacts
Housing material
Ambient temperature
Connection
Mounting method
Operating distance
Switching hysteresis
Repeat accuracy R
Off-state current Ir
Test pulses
Discrepancy time
For the approval acc. to ...
Test-pulse interval
Rated conditional short-c...
Turn-on time
Safety class
Output voltage
EMC protection requiremen...
Rated impulse withstand v...
Utilization category acc....
Operating voltage DC
Switching frequency
Tightening torque
Installation orientation
Ready delay
Static bending radius
Dynamic bending radius
Mounting distance
Shock and vibration resis...
Cable ambient temperature...
Cable ambient temperature...
Extension of risk time ac...
Selected product

099182
Euchner
099182 Euchner - Evaluation unit CMS-E-ER, 2 safety contacts, 1 auxiliary contact, 1 feedback loop c...
Weight0.4960395 lb
SeriesCMS
Product ClassSafety System
Assured release distance Sarmax.31 mm (The assured swit...
Assured operating distance Saomin.6 mm (Figure only appli...
Center offset2,5 mm (Figure only applies...
Mission time20 y (This value is depend...
Number of switching cycles70000 1/Jahr
PFHD1.0 x 10⁻⁷ (This value is d...
Category3 (This value is dependent...
In compliance withEN ISO 13849-1: 2015; EN ISO...
Performance LevelPL d (This value is depende...
Risk time according to EN 60947-5-3max.20 ms
Switching loadInput: 24V AC/DC ; output: ...
Breaking capacity (VA)max.720 VA
Utilization category acc. to EN 60947-5-10.9A , 240V and 0.9A , 24V ...
Switching current10 ... 3000 mA
Degree of contamination (external, according to EN 60947-1)2
Connection cross-section0,14 ... 2,5 mm²
Current consumption10 ... 110 mA
Operating voltage24 V -10% ... +10% V (All ...
Fusing0,75 A Automatically rese...
Rated insulation voltage Ui250 V
LED indicator1 indicator LED Power (UB) a...
Type of outputRelay contacts, floating (2...
Switching voltagemax.240 V
Number of auxiliary contacts1
Degree of protectionTerminals IP20 / housing IP4...
Mechanical life10 x 10⁶
Number of safety contacts2
Housing materialPolyamide PA6.6
Ambient temperature0 ... 55 °C
ConnectionConnection terminals
Mounting methodMounting rail 35mm according...
Operating distance-
Switching hysteresis-
Repeat accuracy R-
Off-state current Ir-
Test pulses-
Discrepancy time-
For the approval acc. to UL the following applies-
Test-pulse interval-
Rated conditional short-circuit current-
Turn-on time-
Safety class-
Output voltage-
EMC protection requirements-
Rated impulse withstand voltage Uimp-
Utilization category acc. to EN 60947-5-2-
Operating voltage DC-
Switching frequency-
Tightening torque-
Installation orientation-
Ready delay-
Static bending radius-
Dynamic bending radius-
Mounting distance-
Shock and vibration resistance-
Cable ambient temperature (static)-
Cable ambient temperature (dynamic)-
Extension of risk time according to EN 60947-5-3 per device-
About the manufacturer

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.
Recently viewed products
Relevant products
FAQ
What is the price of 099182?
The price of 099182 on MQ Automation is $284.41. Order now.
Out if stock but available for backorder.
099182 Euchner - Evaluation unit CMS-E-ER, 2 safety contacts, 1 auxiliary contact, 1 feedback loop can be connected
Similar products from: Safety Accessories
What can I help you find today?