098225 Euchner Safety Accessories
Part#:098225
Alt. Part#:CES-AR-AES-12
Manufacturer:Euchner
Category:Safety Accessories
Product Lifecycle:Active
Mar 15, 2025
Product description
098225 Euchner - AR evaluation unit CES-AR-AES-12
Product Details
- Weight 0.71870612 lb
- Series AR evaluation
- Product Class Safety System
- Mission time 20 y (This value is dependent on the number of switching cycles and the switching current.)
- Performance Level PL e (This value is dependent on the number of switching cycles and the switching current.)
- Number of switching cycles max.720000 1/Jahr
- PFHD 1.5 x 10⁻⁸ (This value is dependent on the number of switching cycles and the switching current.)
- Safety inputs 2 (for CES-AR switch chain)
- Category 4 (This value is dependent on the number of switching cycles and the switching current.)
- Utilization category acc. to EN 60947-5-1 230 V 5 A
- Switching current 1 ... 300 mA
- Discrepancy time max.25 ms
- Number of connectible safety switches max.12
- permissible resistance in feedback loop max.600 Ω
- Current via feedback loop 5 ... 8 ... 10 mA
- Input voltage 0 ... 2 V DC
- Input current 5 ... 8 ... 10 mA
- Actuating duration min.250 ms
- Response delay 300 ... 600 ms
- Output voltage 0 ... 1 V DC
- Output current max.20 mA
- Type of output Semiconductor output, p-switching, short circuit-proof
- Connection cross-section 0,14 ... 2,5 mm²
- Switching delay from state change max.480 ms (Corresponds to the risk time according to EN 60947-5-3. This is the maximum switch-off delay for the safety outputs following removal of the actuator.)
- LED indicator Green LED: Status of the device
- Degree of contamination (external, according to EN 60947-1) 2
- Rated impulse withstand voltage Uimp 4 kV
- EMC protection requirements In acc. with EN 60947-5-3
- Fusing 2,5 ... 8 A
- Rated insulation voltage Ui 250 V
- Mechanical life 10 x 10⁶
- Current consumption 1200 mA (Taking into account the load currents at the monitoring outputs (20 mA each))
- Number of safety contacts 4 Relays with internally monitored contacts
- Operating voltage DC 24 V DC -10% ... 10% Regulated, residual ripple < 5 %
- Switching frequency 1 Hz (If the current load is > 100 mA, a switching frequency of 0.1 Hz should not be exceeded as this will affect the mechanical life of the relay contacts.)
- Connection Plug-in screw terminals coded
- Number of monitoring outputs 12
- Number of LED displays 3
- Shock and vibration resistance In acc. with EN 60947-5-3
- Weight 0,25 kg
- Mounting method Mounting rail 35 mm according to EN 60715
- Degree of protection IP20
- Atmospheric humidity max.80 % rH
- Ready delay max.8 s (After the operating voltage is switched on, the relay outputs are switched off and the monitoring outputs are set LOW during the ready delay. For the visual indication of the delay, the green STATE LED flashes at a frequency of approx. 15 Hz.)
- Ambient temperature -20 ... 55 °C
- Dimensions 114 x 99 x 45
- Housing material Plastic PA6.6
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 098225 on MQ Automation is $858.22. Order now.
About the product
Central evaluation of an AR switch chain;Status of each individual switch can be recognized;For switch chains of up to 12 devices;Four individual safe relay contacts;Category 4/PLe according to EN ISO 13849-1
This item can ship in 3-5 days!
Manufacturer warranty
098225 Euchner
$858.22
Your price can be lower.
Log in or Create account to check your discount
Stock:
Select Qty:
$858.22
$858.22 each
Fast Shipping & Delivery
Secure Payment Processing
Manufacturer warranty
Got Questions? We've Got Answers!
Need more details?
Feel free to chat with us
Compare 098225 with other products
Weight
Series
Product Class
Mission time
Performance Level
Number of switching cycle...
PFHD
Safety inputs
Category
Utilization category acc....
Switching current
Discrepancy time
Number of connectible saf...
permissible resistance in...
Current via feedback loop
Input voltage
Input current
Actuating duration
Response delay
Output voltage
Output current
Type of output
Connection cross-section
Switching delay from stat...
LED indicator
Degree of contamination (...
Rated impulse withstand v...
EMC protection requiremen...
Fusing
Rated insulation voltage ...
Mechanical life
Current consumption
Number of safety contacts
Operating voltage DC
Switching frequency
Connection
Number of monitoring outp...
Number of LED displays
Shock and vibration resis...
Mounting method
Degree of protection
Atmospheric humidity
Ready delay
Ambient temperature
Dimensions
Housing material
B10D
For the approval acc. to ...
Version
Operating current
Switching element
Repeat accuracy R
Detent mechanism
Off-state current Ir
Operating voltage
Safety class
Turn-on time
Switching load
Connection rating
Utilization category acc....
Overtravel
Test-pulse interval
Extraction force
Test pulses
Actuating force
Installation orientation
Approach speed
Additional feature
Risk time according to EN...
Solenoid duty cycle
Solenoid operating voltag...
Extension of risk time ac...
Locking force Fmax
Retention force
Locking force FZh
Guard locking principle
Selected product
Weight0.71870612 lb
SeriesAR evaluation
Product ClassSafety System
Mission time20 y (This value is depend...
Performance LevelPL e (This value is depende...
Number of switching cyclesmax.720000 1/Jahr
PFHD1.5 x 10⁻⁸ (This value is d...
Safety inputs2 (for CES-AR switch chain)
Category4 (This value is dependent...
Utilization category acc. to EN 60947-5-1230 V 5 A
Switching current1 ... 300 mA
Discrepancy timemax.25 ms
Number of connectible safety switchesmax.12
permissible resistance in feedback loopmax.600 Ω
Current via feedback loop5 ... 8 ... 10 mA
Input voltage0 ... 2 V DC
Input current5 ... 8 ... 10 mA
Actuating durationmin.250 ms
Response delay300 ... 600 ms
Output voltage0 ... 1 V DC
Output currentmax.20 mA
Type of outputSemiconductor output, p-swit...
Connection cross-section0,14 ... 2,5 mm²
Switching delay from state changemax.480 ms (Corresponds to ...
LED indicatorGreen LED: Status of the dev...
Degree of contamination (external, according to EN 60947-1)2
Rated impulse withstand voltage Uimp4 kV
EMC protection requirementsIn acc. with EN 60947-5-3
Fusing2,5 ... 8 A
Rated insulation voltage Ui250 V
Mechanical life10 x 10⁶
Current consumption1200 mA (Taking into accoun...
Number of safety contacts4 Relays with internally ...
Operating voltage DC24 V DC -10% ... 10% Regu...
Switching frequency1 Hz (If the current load ...
ConnectionPlug-in screw terminals code...
Number of monitoring outputs12
Number of LED displays3
Shock and vibration resistanceIn acc. with EN 60947-5-3
Mounting methodMounting rail 35 mm accordin...
Degree of protectionIP20
Atmospheric humiditymax.80 % rH
Ready delaymax.8 s (After the operatin...
Ambient temperature-20 ... 55 °C
Dimensions114 x 99 x 45
Housing materialPlastic PA6.6
B10D-
For the approval acc. to UL the following applies-
Version-
Operating current-
Switching element-
Repeat accuracy R-
Detent mechanism-
Off-state current Ir-
Operating voltage-
Safety class-
Turn-on time-
Switching load-
Connection rating-
Utilization category acc. to EN 60947-5-2-
Overtravel-
Test-pulse interval-
Extraction force-
Test pulses-
Actuating force-
Installation orientation-
Approach speed-
Additional feature-
Risk time according to EN 60947-5-3-
Solenoid duty cycle-
Solenoid operating voltage DC-
Extension of risk time according to EN 60947-5-3 per device-
Locking force Fmax-
Retention force-
Locking force FZh-
Guard locking principle-
About the manufacturer

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.
Recently viewed products
Relevant products
FAQ
What is the price of 098225?
The price of 098225 on MQ Automation is $858.22. Order now.
Out if stock but available for backorder.
098225 Euchner - AR evaluation unit CES-AR-AES-12
Similar products from: Safety Accessories
What can I help you find today?