098225 Euchner Safety Accessories

098225 on MQ Automation
Euchner
  • 098225
  • 098225
  • 098225

Part#:098225

Alt. Part#:CES-AR-AES-12

Manufacturer:Euchner

Category:Safety Accessories

Product Lifecycle:Active

Only 2 left in stock. Order Now!

Mar 15, 2025

Product description

098225 Euchner - AR evaluation unit CES-AR-AES-12

Product Details

  • Weight
    0.71870612 lb
  • Series
    AR evaluation
  • Product Class
    Safety System
  • Mission time
    20 y (This value is dependent on the number of switching cycles and the switching current.)
  • Performance Level
    PL e (This value is dependent on the number of switching cycles and the switching current.)
  • Number of switching cycles
    max.720000 1/Jahr
  • PFHD
    1.5 x 10⁻⁸ (This value is dependent on the number of switching cycles and the switching current.)
  • Safety inputs
    2 (for CES-AR switch chain)
  • Category
    4 (This value is dependent on the number of switching cycles and the switching current.)
  • Utilization category acc. to EN 60947-5-1
    230 V 5 A
  • Switching current
    1 ... 300 mA
  • Discrepancy time
    max.25 ms
  • Number of connectible safety switches
    max.12
  • permissible resistance in feedback loop
    max.600 Ω
  • Current via feedback loop
    5 ... 8 ... 10 mA
  • Input voltage
    0 ... 2 V DC
  • Input current
    5 ... 8 ... 10 mA
  • Actuating duration
    min.250 ms
  • Response delay
    300 ... 600 ms
  • Output voltage
    0 ... 1 V DC
  • Output current
    max.20 mA
  • Type of output
    Semiconductor output, p-switching, short circuit-proof
  • Connection cross-section
    0,14 ... 2,5 mm²
  • Switching delay from state change
    max.480 ms (Corresponds to the risk time according to EN 60947-5-3. This is the maximum switch-off delay for the safety outputs following removal of the actuator.)
  • LED indicator
    Green LED: Status of the device
  • Degree of contamination (external, according to EN 60947-1)
    2
  • Rated impulse withstand voltage Uimp
    4 kV
  • EMC protection requirements
    In acc. with EN 60947-5-3
  • Fusing
    2,5 ... 8 A
  • Rated insulation voltage Ui
    250 V
  • Mechanical life
    10 x 10⁶
  • Current consumption
    1200 mA (Taking into account the load currents at the monitoring outputs (20 mA each))
  • Number of safety contacts
    4 Relays with internally monitored contacts
  • Operating voltage DC
    24 V DC -10% ... 10% Regulated, residual ripple < 5 %
  • Switching frequency
    1 Hz (If the current load is > 100 mA, a switching frequency of 0.1 Hz should not be exceeded as this will affect the mechanical life of the relay contacts.)
  • Connection
    Plug-in screw terminals coded
  • Number of monitoring outputs
    12
  • Number of LED displays
    3
  • Shock and vibration resistance
    In acc. with EN 60947-5-3
  • Weight
    0,25 kg
  • Mounting method
    Mounting rail 35 mm according to EN 60715
  • Degree of protection
    IP20
  • Atmospheric humidity
    max.80 % rH
  • Ready delay
    max.8 s (After the operating voltage is switched on, the relay outputs are switched off and the monitoring outputs are set LOW during the ready delay. For the visual indication of the delay, the green STATE LED flashes at a frequency of approx. 15 Hz.)
  • Ambient temperature
    -20 ... 55 °C
  • Dimensions
    114 x 99 x 45
  • Housing material
    Plastic PA6.6

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 098225 on MQ Automation is $858.22. Order now.


About the product

Central evaluation of an AR switch chain;Status of each individual switch can be recognized;For switch chains of up to 12 devices;Four individual safe relay contacts;Category 4/PLe according to EN ISO 13849-1


This item can ship in 3-5 days!

Manufacturer warranty

098225 Euchner

$858.22

Your price can be lower.
Log in or Create account to check your discount

Stock:

2

Select Qty:

$858.22

$858.22 each

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 098225 with other products

Weight

Series

Product Class

Mission time

Performance Level

Number of switching cycle...

PFHD

Safety inputs

Category

Utilization category acc....

Switching current

Discrepancy time

Number of connectible saf...

permissible resistance in...

Current via feedback loop

Input voltage

Input current

Actuating duration

Response delay

Output voltage

Output current

Type of output

Connection cross-section

Switching delay from stat...

LED indicator

Degree of contamination (...

Rated impulse withstand v...

EMC protection requiremen...

Fusing

Rated insulation voltage ...

Mechanical life

Current consumption

Number of safety contacts

Operating voltage DC

Switching frequency

Connection

Number of monitoring outp...

Number of LED displays

Shock and vibration resis...

Mounting method

Degree of protection

Atmospheric humidity

Ready delay

Ambient temperature

Dimensions

Housing material

B10D

For the approval acc. to ...

Version

Operating current

Switching element

Repeat accuracy R

Detent mechanism

Off-state current Ir

Operating voltage

Safety class

Turn-on time

Switching load

Connection rating

Utilization category acc....

Overtravel

Test-pulse interval

Extraction force

Test pulses

Actuating force

Installation orientation

Approach speed

Additional feature

Risk time according to EN...

Solenoid duty cycle

Solenoid operating voltag...

Extension of risk time ac...

Locking force Fmax

Retention force

Locking force FZh

Guard locking principle

Selected product

098225
2 in stock
098225
Euchner

098225 Euchner - AR evaluation unit CES-AR-AES-12

Weight0.71870612 lb

SeriesAR evaluation

Product ClassSafety System

Mission time20 y (This value is depend...

Performance LevelPL e (This value is depende...

Number of switching cyclesmax.720000 1/Jahr

PFHD1.5 x 10⁻⁸ (This value is d...

Safety inputs2 (for CES-AR switch chain)

Category4 (This value is dependent...

Utilization category acc. to EN 60947-5-1230 V 5 A

Switching current1 ... 300 mA

Discrepancy timemax.25 ms

Number of connectible safety switchesmax.12

permissible resistance in feedback loopmax.600 Ω

Current via feedback loop5 ... 8 ... 10 mA

Input voltage0 ... 2 V DC

Input current5 ... 8 ... 10 mA

Actuating durationmin.250 ms

Response delay300 ... 600 ms

Output voltage0 ... 1 V DC

Output currentmax.20 mA

Type of outputSemiconductor output, p-swit...

Connection cross-section0,14 ... 2,5 mm²

Switching delay from state changemax.480 ms (Corresponds to ...

LED indicatorGreen LED: Status of the dev...

Degree of contamination (external, according to EN 60947-1)2

Rated impulse withstand voltage Uimp4 kV

EMC protection requirementsIn acc. with EN 60947-5-3

Fusing2,5 ... 8 A

Rated insulation voltage Ui250 V

Mechanical life10 x 10⁶

Current consumption1200 mA (Taking into accoun...

Number of safety contacts4 Relays with internally ...

Operating voltage DC24 V DC -10% ... 10% Regu...

Switching frequency1 Hz (If the current load ...

ConnectionPlug-in screw terminals code...

Number of monitoring outputs12

Number of LED displays3

Shock and vibration resistanceIn acc. with EN 60947-5-3

Mounting methodMounting rail 35 mm accordin...

Degree of protectionIP20

Atmospheric humiditymax.80 % rH

Ready delaymax.8 s (After the operatin...

Ambient temperature-20 ... 55 °C

Dimensions114 x 99 x 45

Housing materialPlastic PA6.6

B10D-

For the approval acc. to UL the following applies-

Version-

Operating current-

Switching element-

Repeat accuracy R-

Detent mechanism-

Off-state current Ir-

Operating voltage-

Safety class-

Turn-on time-

Switching load-

Connection rating-

Utilization category acc. to EN 60947-5-2-

Overtravel-

Test-pulse interval-

Extraction force-

Test pulses-

Actuating force-

Installation orientation-

Approach speed-

Additional feature-

Risk time according to EN 60947-5-3-

Solenoid duty cycle-

Solenoid operating voltage DC-

Extension of risk time according to EN 60947-5-3 per device-

Locking force Fmax-

Retention force-

Locking force FZh-

Guard locking principle-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

SeriesMGBS-P-I-AP

Product ClassSafety System

Mission time20 y

Performance LevelPL e

Number of switching cycles-

PFHD4.1 x 10 ⁻⁹

Safety inputs-

Category4

Utilization category acc. to EN 60947-5-1-

Switching current1 ... 150 mA

Discrepancy timemax.10 ms In acc. with EN ...

Number of connectible safety switches-

permissible resistance in feedback loop-

Current via feedback loop-

Input voltage-

Input current-

Actuating duration-

Response delay-

Output voltage0 ... 1 V DC

Output current-

Type of output2 semiconductor outputs, p-s...

Connection cross-section-

Switching delay from state change-

LED indicator-

Degree of contamination (external, according to EN 60947-1)3

Rated impulse withstand voltage Uimp0,5 kV

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Fusing0,25 ... 8 A

Rated insulation voltage Ui50 V

Mechanical life1 x 10⁶

Current consumption40 mA

Number of safety contacts-

Operating voltage DC24 V DC -15% ... 15% Rev...

Switching frequencymax.0,5 Hz

Connection2 plug connectors M12, 5-pin

Number of monitoring outputs-

Number of LED displays-

Shock and vibration resistanceIn acc. with EN 60947-5-3

Mounting method-

Degree of protectionIP65 (Screwed tight plug co...

Atmospheric humidity-

Ready delaymax.1 s

Ambient temperature-20 ... +55 °C

Dimensions-

Housing materialFiber glass reinforced therm...

B10D0,13 x 10⁶

For the approval acc. to UL the following appliesOperation only with UL class...

VersionEmergency stop

Operating current1 ... 100 mA

Switching element2 pos. driven NC

Repeat accuracy R10 %

Detent mechanismSnap-in bolt

Off-state current Irmax.0,25 mA

Operating voltage5 ... 24 V

Safety classIII

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

Connection rating1 W

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Overtravel5 mm

Test-pulse intervalmin.100 ms

Extraction force20 N

Test pulsesmax.0,3 ms (Applies for a l...

Actuating force10 N

Installation orientationDoor hinge DIN right

Approach speedmax.20 m/min

Additional feature-

Risk time according to EN 60947-5-3-

Solenoid duty cycle-

Solenoid operating voltage DC-

Extension of risk time according to EN 60947-5-3 per device-

Locking force Fmax-

Retention force-

Locking force FZh-

Guard locking principle-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

Mission time20 y

Performance LevelPL e

Number of switching cycles-

PFHD4.1 x 10 ⁻⁹

Safety inputs-

Category4

Utilization category acc. to EN 60947-5-1-

Switching current1 ... 50 mA

Discrepancy timemax.10 ms In acc. with EN ...

Number of connectible safety switches-

permissible resistance in feedback loop-

Current via feedback loop-

Input voltage-

Input current-

Actuating duration-

Response delay-

Output voltage0,8xUB ... UB V DC

Output current-

Type of outputp-switching, short circuit-p...

Connection cross-section-

Switching delay from state change-

LED indicator-

Degree of contamination (external, according to EN 60947-1)3

Rated impulse withstand voltage Uimp0,5 kV

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Fusing0,25 ... 8 A

Rated insulation voltage Ui50 V

Mechanical life1 x 10⁶

Current consumption40 mA

Number of safety contacts-

Operating voltage DC24 V DC -15% ... 15% Rev...

Switching frequencymax.0,5 Hz

Connection2 plug connectors M12, 5 and...

Number of monitoring outputs-

Number of LED displays-

Shock and vibration resistanceIn acc. with EN 60947-5-3

Mounting method-

Degree of protectionIP67/IP69/IP69K (Screwed ti...

Atmospheric humidity-

Ready delay8 s

Ambient temperature-20 ... +55 °C

Dimensions-

Housing materialDie-cast zinc

B10D-

For the approval acc. to UL the following appliesOperation only with UL class...

Version-

Operating current-

Switching element-

Repeat accuracy R10 %

Detent mechanism-

Off-state current Irmax.0,25 mA

Operating voltage-

Safety classIII

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

Connection rating6 W

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Overtravel5 mm

Test-pulse intervalmin.140 ms

Extraction force20 N

Test pulsesmax.1,0 ms (Applies for a l...

Actuating force10 N

Installation orientationAny

Approach speedmax.20 m/min

Additional featureEscape release actuated by p...

Risk time according to EN 60947-5-3max.260 ms

Solenoid duty cycle100 %

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Locking force Fmax3900 N

Retention force20 N

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Guard locking principleClosed-circuit current princ...

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 098225?
The price of 098225 on MQ Automation is $858.22. Order now.

Out if stock but available for backorder.

098225 Euchner - AR evaluation unit CES-AR-AES-12

What can I help you find today?

Recommended parts