097525 Euchner Safety Proximity Sensors

097525 on MQ Automation
Euchner
  • 097525
  • 097525
  • 097525

Part#:097525

Alt. Part#:CES-A-W5H-01

Manufacturer:Euchner

Category:Safety Proximity Sensors

Product Lifecycle:Active

Product description

097525 Euchner - Non-contact safety switch CES-A-W5...

Product Details

  • Weight
    0.76941238 lb
  • Series
    CES-A-.5
  • Product Class
    Safety System
  • Switching hysteresis
    min.2 mm (In non-metallic environment)
  • Assured operating distance Sao
    min.19 mm (In non-metallic environment)
  • Assured release distance Sar
    max.41 mm
  • Distance s, actuator
    min.4 mm
  • Operating distance
    21 mm (In non-metallic environment)
  • Diagnostic Coverage (DC)
    99 %
  • Power supply output load
    24 V DC 18 ... 27 V DC
  • Mission time
    20 y
  • PFHD
    3.7 x 10⁻⁹
  • Performance Level
    PL e
  • Category
    4 (Category 4 according to EN 13849-1 for monitoring short circuits of safety outputs. A short circuit on LA and LB must be detected by external pulsing or must be excluded by laying the cable with protection.)
  • Repeat accuracy R
    max.10 %
  • For the approval acc. to UL the following applies
    Operation only with UL class 2 power supply, or equivalent measures
  • Discrepancy time
    max.120 ms
  • Rated conditional short-circuit current
    max.100 A
  • Switching load
    max. DC 24 V, class 2
  • Utilization category acc. to EN 60947-5-2
    24V 400mA
  • Type of output
    Semiconductor outputs, p-switching, short circuit-proof, electrically decoupled (To ensure safety, both safety outputs (LA and LB) must be evaluated.)
  • Output current
    1 ... 400 mA
  • LED indicator
    Safety outputs status / diagnostics (combined)
  • Output voltage
    U(+LA) - 1,5 ... U(+LA) V DC
  • Rated impulse withstand voltage Uimp
    1,5 kV
  • EMC protection requirements
    In acc. with EN 60947-5-3
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Connection
    M12 plug connector, 8-pin, screen can be applied
  • Operating voltage DC
    18 ... 24 ... 27 V DC Regulated, residual ripple < 5 %
  • Rated insulation voltage Ui
    300 V (Tested by employers' liability insurance association up to 75 V.)
  • Fusing
    0,25 ... 8 A
  • Dwell time
    min.0,5 s (The dwell time of an actuator inside and outside the operating distance must be at least 0.5 s to ensure reliable detection of internal faults in the evaluation unit (self-monitoring).)
  • Reaction time
    max.180 ms (Corresponds to the risk time according to EN 60947-5-3. This is the maximum switch-off delay for the safety outputs following removal of the actuator.)
  • Current consumption
    80 mA
  • Switching frequency
    max.1 Hz
  • Ready delay
    max.3 s (After the operating voltage is switched on, the semiconductor outputs are switched off and the monitoring outputs are set LOW during the ready delay.)
  • Degree of protection
    IP65/IP67
  • Tightening torque
    max.1 Nm
  • Mounting distance
    min.80 mm
  • Ambient temperature
    -20 ... 55 °C
  • Installation orientation
    Any
  • Weight
    0,4 kg
  • Housing material
    Plastic, PBT
  • Dimensions
    According to EN 60947-5-2: (LxWxH) 131x40x40

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 097525 on MQ Automation is $346.72. Order now.


About the product

Safety switch with integrated evaluation electronics;Pulsed signals can be switched;2 safety outputs (semiconductor outputs);Category 4 / PL e according to EN ISO 13849-1;Multicode


Manufacturer warranty

097525 Euchner

$346.72

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$346.72

$346.72 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 097525 with other products

Weight

Series

Product Class

Switching hysteresis

Assured operating distanc...

Assured release distance ...

Distance s, actuator

Operating distance

Diagnostic Coverage (DC)

Power supply output load

Mission time

PFHD

Performance Level

Category

Repeat accuracy R

For the approval acc. to ...

Discrepancy time

Rated conditional short-c...

Switching load

Utilization category acc....

Type of output

Output current

LED indicator

Output voltage

Rated impulse withstand v...

EMC protection requiremen...

Degree of contamination (...

Connection

Operating voltage DC

Rated insulation voltage ...

Fusing

Dwell time

Reaction time

Current consumption

Switching frequency

Ready delay

Degree of protection

Tightening torque

Mounting distance

Ambient temperature

Installation orientation

Housing material

Dimensions

Off-state current Ir

Test pulses

Test-pulse interval

Switching current

Turn-on time

Risk time according to EN...

Safety class

Extension of risk time ac...

Cable ambient temperature...

Mounting method

Static bending radius

Shock and vibration resis...

Cable ambient temperature...

Dynamic bending radius

Selected product

097525
0 in stock
097525
Euchner

097525 Euchner - Non-contact safety switch CES-A-W5...

Weight0.76941238 lb

SeriesCES-A-.5

Product ClassSafety System

Switching hysteresismin.2 mm (In non-metallic e...

Assured operating distance Saomin.19 mm (In non-metallic ...

Assured release distance Sarmax.41 mm

Distance s, actuatormin.4 mm

Operating distance21 mm (In non-metallic envi...

Diagnostic Coverage (DC)99 %

Power supply output load24 V DC 18 ... 27 V DC

Mission time20 y

PFHD3.7 x 10⁻⁹

Performance LevelPL e

Category4 (Category 4 according to...

Repeat accuracy Rmax.10 %

For the approval acc. to UL the following appliesOperation only with UL class...

Discrepancy timemax.120 ms

Rated conditional short-circuit currentmax.100 A

Switching loadmax. DC 24 V, class 2

Utilization category acc. to EN 60947-5-224V 400mA

Type of outputSemiconductor outputs, p-swi...

Output current1 ... 400 mA

LED indicatorSafety outputs status / diag...

Output voltageU(+LA) - 1,5 ... U(+LA) V D...

Rated impulse withstand voltage Uimp1,5 kV

EMC protection requirementsIn acc. with EN 60947-5-3

Degree of contamination (external, according to EN 60947-1)3

ConnectionM12 plug connector, 8-pin, s...

Operating voltage DC18 ... 24 ... 27 V DC Regu...

Rated insulation voltage Ui300 V (Tested by employers...

Fusing0,25 ... 8 A

Dwell timemin.0,5 s (The dwell time o...

Reaction timemax.180 ms (Corresponds to ...

Current consumption80 mA

Switching frequencymax.1 Hz

Ready delaymax.3 s (After the operatin...

Degree of protectionIP65/IP67

Tightening torquemax.1 Nm

Mounting distancemin.80 mm

Ambient temperature-20 ... 55 °C

Installation orientationAny

Housing materialPlastic, PBT

DimensionsAccording to EN 60947-5-2: (...

Off-state current Ir-

Test pulses-

Test-pulse interval-

Switching current-

Turn-on time-

Risk time according to EN 60947-5-3-

Safety class-

Extension of risk time according to EN 60947-5-3 per device-

Cable ambient temperature (dynamic)-

Mounting method-

Static bending radius-

Shock and vibration resistance-

Cable ambient temperature (static)-

Dynamic bending radius-

105748
2 in stock
105748
Euchner

105748 Euchner - Non-contact safety switch CES-AR-CL2-... , plug connector M12, PUR

Weight0.29100984 lb

SeriesCES-AR

Product ClassSafety System

Switching hysteresismin.1 mm

Assured operating distance Saomin.14 mm

Assured release distance Sarmax.60 mm

Distance s, actuator-

Operating distance19 mm

Diagnostic Coverage (DC)-

Power supply output load-

Mission time20

PFHD1.9 x 10⁻⁹

Performance LevelPL e

Category4

Repeat accuracy R≤ 10

For the approval acc. to UL the following appliesOperation only with UL class...

Discrepancy timemax.10 ms

Rated conditional short-circuit current100 A

Switching load-

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Type of outputp-switching, short circuit-p...

Output current-

LED indicator-

Output voltage0,8 x UB ... UB V DC

Rated impulse withstand voltage Uimp1,5 kV

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Degree of contamination (external, according to EN 60947-1)3

ConnectionConnection cable PUR, length...

Operating voltage DC24 V DC 15% ... 15% Regu...

Rated insulation voltage Ui75 V

Fusing0,25 ... 8 A

Dwell time-

Reaction time-

Current consumptionmax.50 mA (Without taking i...

Switching frequencymax.1 Hz

Ready delay10 s

Degree of protectionIP67

Tightening torquemax.1 Nm

Mounting distancemin.120 mm

Ambient temperature-

Installation orientationAny

Housing materialPlastic, PBT

Dimensions-

Off-state current Irmax.0,25 mA

Test pulsesmax.1 ms (Applies for a loa...

Test-pulse intervalmin.140 ms

Switching currentmax.50 mA

Turn-on timemax.400 ms

Risk time according to EN 60947-5-3max.260 ms

Safety classIII

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Cable ambient temperature (dynamic)-25 ... 65 °C

Mounting methodSurface mounting on metal

Static bending radius5 x cable diameter

Shock and vibration resistanceIn acc. with EN 60947-5-3

Cable ambient temperature (static)-25 ... 65 °C

Dynamic bending radius10 x cable diameter

105602
3 in stock
105602
Euchner

105602 Euchner - Non-contact safety switch CES-AP-CL2-..., flying lead, PVC

Weight0.52029032 lb

SeriesCES-AP

Product ClassSafety System

Switching hysteresismin.1 mm

Assured operating distance Saomin.14 mm

Assured release distance Sarmax.60 mm

Distance s, actuator-

Operating distance19 mm

Diagnostic Coverage (DC)-

Power supply output load-

Mission time20

PFHD1.8 x 10⁻⁹

Performance LevelPL e

Category4

Repeat accuracy R≤ 10

For the approval acc. to UL the following appliesOperation only with UL class...

Discrepancy timemax.10 ms

Rated conditional short-circuit current100 A

Switching load-

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Type of outputp-switching, short circuit-p...

Output current-

LED indicator-

Output voltage0,8 x UB ... UB V DC

Rated impulse withstand voltage Uimp1,5 kV

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Degree of contamination (external, according to EN 60947-1)3

Connectionconnection cable PVC, length...

Operating voltage DC24 V DC 15% ... 15% Regu...

Rated insulation voltage Ui75 V

Fusing0,25 ... 8 A

Dwell time-

Reaction time-

Current consumptionmax.30 mA (Without taking i...

Switching frequencymax.1 Hz

Ready delay0,5 s

Degree of protectionIP67, IP69K

Tightening torquemax.1 Nm

Mounting distancemin.400 mm

Ambient temperature-

Installation orientationAny

Housing materialPlastic, PBT

Dimensions-

Off-state current Irmax.0,25 mA

Test pulsesmax.0,3 ms (Applies for a l...

Test-pulse intervalmin.100 ms

Switching currentmax.50 mA

Turn-on timemax.300 ms

Risk time according to EN 60947-5-3max.260 ms

Safety classIII

Extension of risk time according to EN 60947-5-3 per device-

Cable ambient temperature (dynamic)0 ... 65 °C

Mounting methodSurface mounting on metal

Static bending radius5 x cable diameter

Shock and vibration resistanceIn acc. with EN 60947-5-3

Cable ambient temperature (static)-40 ... 65 °C

Dynamic bending radius10 x cable diameter

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

FAQ

What is the price of 097525?
The price of 097525 on MQ Automation is $346.72. Order now.

Out if stock but available for backorder.

097525 Euchner - Non-contact safety switch CES-A-W5...

What can I help you find today?

Recommended parts