097339 Euchner Pendant Control Stations

097339 on MQ Automation
Euchner

Part#:097339

Alt. Part#:HBL-097339 ALT: 072598

Manufacturer:Euchner

Category:Pendant Control Stations

Product Lifecycle:Active

Product description

097339 Euchner - PENDANT STATION

Product Details

  • Weight
    4.91715 lb
  • For the approval acc. to UL the following applies
    Operation only with UL class 2 power supply, or equivalent measures
  • Position
    See data sheets
  • Switching element
    12-stage, hex-coded, detent angle 30°
  • Color
    Black knob with arrow disk
  • Version
    Selector switch
  • Power supply LED
    24 V DC -10% ... +10% V DC (AC/DC)
  • Special features
    -
  • Breaking capacity (VA)
    max.6 VA
  • Connecting cable
    35x0.14mm² (Screened)
  • Pulses per revolution
    2x100
  • Type of output
    RS422
  • EMC protection requirements
    EN 61000-6-2, EN 61000-6-4
  • Switching current
    max.3000 mA (On DC-13)
  • Switching voltage
    DC 5 ... DC 230 V
  • Shock and vibration resistance
    Acc. to EN 60068-2-27/-2-6
  • Utilization category acc. to EN 60947-5-2
    max.42V / 1A
  • Connection
    Plug connector (35-pin, metal version)
  • Operating voltage DC
    5 V DC -5% ... 5%
  • Cable length
    3,5 m
  • Material
    Polyamide
  • Ambient temperature
    0 ... 55 °C
  • Atmospheric humidity
    max.80 % rH
  • Degree of protection
    250-12 (On the front)
  • Detent positions per revolution
    100
  • Weight
    2,2 kg

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 097339 on MQ Automation is $2,941.01. Order now.


Manufacturer warranty

097339 Euchner

$2,941.01

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$2,941.01

$2,941.01 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 097339 with other products

Weight

For the approval acc. to ...

Position

Switching element

Color

Version

Power supply LED

Special features

Breaking capacity (VA)

Connecting cable

Pulses per revolution

Type of output

EMC protection requiremen...

Switching current

Switching voltage

Shock and vibration resis...

Utilization category acc....

Connection

Operating voltage DC

Cable length

Material

Ambient temperature

Atmospheric humidity

Degree of protection

Detent positions per revo...

Series

Product Class

B10D

Mission time

PFHD

Performance Level

Category

Operating current

Repeat accuracy R

Detent mechanism

Discrepancy time

Off-state current Ir

Operating voltage

Safety class

Turn-on time

Switching load

Output voltage

Degree of contamination (...

Rated insulation voltage ...

Rated impulse withstand v...

Connection rating

Fusing

Current consumption

Overtravel

Test-pulse interval

Extraction force

Test pulses

Actuating force

Installation orientation

Mechanical life

Housing material

Approach speed

Switching frequency

Ready delay

Assured operating distanc...

Switching hysteresis

Assured release distance ...

Operating distance

Additional feature

Rated conditional short-c...

Risk time according to EN...

Extension of risk time ac...

Tightening torque

Mounting method

Mounting distance

Cable ambient temperature...

Cable ambient temperature...

Dynamic bending radius

Static bending radius

Selected product

097339
0 in stock
097339
Euchner

097339 Euchner - PENDANT STATION

Weight4.91715 lb

For the approval acc. to UL the following appliesOperation only with UL class...

PositionSee data sheets

Switching element12-stage, hex-coded, detent ...

ColorBlack knob with arrow disk

VersionSelector switch

Power supply LED24 V DC -10% ... +10% V DC...

Special features-

Breaking capacity (VA)max.6 VA

Connecting cable35x0.14mm² (Screened)

Pulses per revolution2x100

Type of outputRS422

EMC protection requirementsEN 61000-6-2, EN 61000-6-4

Switching currentmax.3000 mA (On DC-13)

Switching voltageDC 5 ... DC 230 V

Shock and vibration resistanceAcc. to EN 60068-2-27/-2-6

Utilization category acc. to EN 60947-5-2max.42V / 1A

ConnectionPlug connector (35-pin, met...

Operating voltage DC5 V DC -5% ... 5%

Cable length3,5 m

MaterialPolyamide

Ambient temperature0 ... 55 °C

Atmospheric humiditymax.80 % rH

Degree of protection250-12 (On the front)

Detent positions per revolution100

Series-

Product Class-

B10D-

Mission time-

PFHD-

Performance Level-

Category-

Operating current-

Repeat accuracy R-

Detent mechanism-

Discrepancy time-

Off-state current Ir-

Operating voltage-

Safety class-

Turn-on time-

Switching load-

Output voltage-

Degree of contamination (external, according to EN 60947-1)-

Rated insulation voltage Ui-

Rated impulse withstand voltage Uimp-

Connection rating-

Fusing-

Current consumption-

Overtravel-

Test-pulse interval-

Extraction force-

Test pulses-

Actuating force-

Installation orientation-

Mechanical life-

Housing material-

Approach speed-

Switching frequency-

Ready delay-

Assured operating distance Sao-

Switching hysteresis-

Assured release distance Sar-

Operating distance-

Additional feature-

Rated conditional short-circuit current-

Risk time according to EN 60947-5-3-

Extension of risk time according to EN 60947-5-3 per device-

Tightening torque-

Mounting method-

Mounting distance-

Cable ambient temperature (static)-

Cable ambient temperature (dynamic)-

Dynamic bending radius-

Static bending radius-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

For the approval acc. to UL the following appliesOperation only with UL class...

Position-

Switching element2 pos. driven NC

Color-

VersionEmergency stop

Power supply LED-

Special features-

Breaking capacity (VA)-

Connecting cable-

Pulses per revolution-

Type of output2 semiconductor outputs, p-s...

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Switching current1 ... 150 mA

Switching voltage-

Shock and vibration resistanceIn acc. with EN 60947-5-3

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Connection2 plug connectors M12, 5-pin

Operating voltage DC24 V DC -15% ... 15% Rev...

Cable length-

Material-

Ambient temperature-20 ... +55 °C

Atmospheric humidity-

Degree of protectionIP65 (Screwed tight plug co...

Detent positions per revolution-

SeriesMGBS-P-I-AP

Product ClassSafety System

B10D0,13 x 10⁶

Mission time20 y

PFHD4.1 x 10 ⁻⁹

Performance LevelPL e

Category4

Operating current1 ... 100 mA

Repeat accuracy R10 %

Detent mechanismSnap-in bolt

Discrepancy timemax.10 ms In acc. with EN ...

Off-state current Irmax.0,25 mA

Operating voltage5 ... 24 V

Safety classIII

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

Output voltage0 ... 1 V DC

Degree of contamination (external, according to EN 60947-1)3

Rated insulation voltage Ui50 V

Rated impulse withstand voltage Uimp0,5 kV

Connection rating1 W

Fusing0,25 ... 8 A

Current consumption40 mA

Overtravel5 mm

Test-pulse intervalmin.100 ms

Extraction force20 N

Test pulsesmax.0,3 ms (Applies for a l...

Actuating force10 N

Installation orientationDoor hinge DIN right

Mechanical life1 x 10⁶

Housing materialFiber glass reinforced therm...

Approach speedmax.20 m/min

Switching frequencymax.0,5 Hz

Ready delaymax.1 s

Assured operating distance Sao-

Switching hysteresis-

Assured release distance Sar-

Operating distance-

Additional feature-

Rated conditional short-circuit current-

Risk time according to EN 60947-5-3-

Extension of risk time according to EN 60947-5-3 per device-

Tightening torque-

Mounting method-

Mounting distance-

Cable ambient temperature (static)-

Cable ambient temperature (dynamic)-

Dynamic bending radius-

Static bending radius-

119473
23 in stock
119473
Euchner

119473 Euchner - Non-contact safety switches CES-I-AR-.-C04-…, M12

Weight0.23589434 lb

For the approval acc. to UL the following appliesOperation only with UL class...

Position-

Switching element-

Color-

Version-

Power supply LED-

Special features-

Breaking capacity (VA)-

Connecting cable-

Pulses per revolution-

Type of outputSemiconductor output, p-swit...

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Switching currentmax.50 mA

Switching voltage-

Shock and vibration resistanceIn acc. with EN 60947-5-3

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

ConnectionConnection cable PUR, length...

Operating voltage DC24 V DC 15% ... 15% Regu...

Cable length-

MaterialNBR 80 ±5 Shore

Ambient temperature-

Atmospheric humidity-

Degree of protectionIP67

Detent positions per revolution-

SeriesCES-AR

Product ClassSafety System

B10D-

Mission time20

PFHD4.1 x 10⁻⁹

Performance LevelPL e

Category4

Operating current-

Repeat accuracy R≤ 10

Detent mechanism-

Discrepancy timemax.10 ms

Off-state current Irmax.0,25 mA

Operating voltage-

Safety classIII

Turn-on timemax.400 ms

Switching load-

Output voltage0,8 x UB ... UB V DC

Degree of contamination (external, according to EN 60947-1)3

Rated insulation voltage Ui300 V

Rated impulse withstand voltage Uimp1,5 kV

Connection rating-

Fusing0,25 ... 8 A

Current consumptionmax.35 mA (Without taking i...

Overtravel-

Test-pulse intervalmin.140 ms

Extraction force-

Test pulsesmax.1,0 ms (Applies for a l...

Actuating force-

Installation orientationAny

Mechanical life-

Housing materialPlastic, PBT

Approach speed-

Switching frequencymax.1 Hz

Ready delay10 s

Assured operating distance Sao6

Switching hysteresismin.1 mm

Assured release distance Sarmax.60 mm

Operating distance11 mm

Additional featureRubber support included

Rated conditional short-circuit current100 A

Risk time according to EN 60947-5-3max.260 ms

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Tightening torquemax.0,8 Nm

Mounting methodSurface mounting on metal

Mounting distancemin.80 mm

Cable ambient temperature (static)-25 ... 65 °C

Cable ambient temperature (dynamic)-25 ... 65 °C

Dynamic bending radius10 x cable diameter

Static bending radius5 x cable diameter

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 097339?
The price of 097339 on MQ Automation is $2,941.01. Order now.

Out if stock but available for backorder.

097339 Euchner - PENDANT STATION

What can I help you find today?

Recommended parts