095170 Euchner Safety Proximity Sensors

095170 on MQ Automation
Euchner
  • 095170
  • 095170
  • 095170

Part#:095170

Alt. Part#:CEM-A-LH10K-S3

Manufacturer:Euchner

Category:Safety Proximity Sensors

Product Lifecycle:Active

Product description

095170 Euchner - Read head CEM-A-LH10K-S3 with guard locking without guard lock monitoring with remanence

Product Details

  • Weight
    1.90258706 lb
  • Series
    CEM read heads
  • Product Class
    Safety System
  • Center offset
    -2,5 ... +2,5 mm
  • Assured release distance Sar
    max.20 mm (In conjunction with evaluation unit CES-A-...B or CES-AZ-...B)
  • Switching hysteresis
    0,7 mm (In conjunction with evaluation unit CES-A-...B or CES-AZ-...B)
  • Assured operating distance Sao
    min.2 mm (In conjunction with evaluation unit CES-A-...B or CES-AZ-...B)
  • Solenoid duty cycle
    100 %
  • Current consumption
    225 mA
  • Connection rating
    5,4 W
  • Operating voltage DC
    24 V DC -15% ... 10%
  • Adhesive force
    40 N -25% ... +25%
  • Locking force F
    1000 N
  • Cable length
    max.25 m
  • Guard locking principle
    Open-circuit current principle
  • Connection
    Plug connector M8x1, 4-pin female (with screw terminal)
  • Installation orientation
    Any
  • Housing material
    Die-cast aluminum
  • Material
    Steel, nickel-plated
  • Switching frequency
    max.1 Hz
  • Mechanical life
    1 x 10⁶
  • Read head material
    Plastic (PPS)
  • Degree of protection
    IP67
  • Ambient temperature
    -25 ... 50 °C
  • Weight
    0,9 kg

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 095170 on MQ Automation is $499.56. Order now.


About the product

Read head with guard locking without guard lock monitoring;Locking force 1000 N;With remanence;Up to category 4 according to EN ISO 13849-1


Manufacturer warranty

095170 Euchner

$499.56

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$499.56

$499.56 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 095170 with other products

Weight

Series

Product Class

Center offset

Assured release distance ...

Switching hysteresis

Assured operating distanc...

Solenoid duty cycle

Current consumption

Connection rating

Operating voltage DC

Adhesive force

Locking force F

Cable length

Guard locking principle

Connection

Installation orientation

Housing material

Material

Switching frequency

Mechanical life

Read head material

Degree of protection

Ambient temperature

Mission time

PFHD

Category

Performance Level

For the approval acc. to ...

Additional feature

Repeat accuracy R

Discrepancy time

Output voltage

Turn-on time

Off-state current Ir

Switching current

Type of output

Switching load

Risk time according to EN...

Safety class

Degree of contamination (...

EMC protection requiremen...

Rated impulse withstand v...

Rated insulation voltage ...

Fusing

Solenoid operating voltag...

Utilization category acc....

Test pulses

Test-pulse interval

Actuating force

Extension of risk time ac...

Extraction force

Overtravel

Locking force Fmax

Approach speed

Retention force

Locking force FZh

Ready delay

Shock and vibration resis...

B10D

Connection cross-section

Switching voltage

Short circuit protection ...

Solenoid operating voltag...

Thermal rated current Ith

Insertion depth

Utilization category acc....

Actuation frequency

Number of door position N...

Number of guard lock moni...

Number of door position N...

Switching principle

Contact material

Selected product

095170
0 in stock
095170
Euchner

095170 Euchner - Read head CEM-A-LH10K-S3 with guard locking without guard lock monitoring with rema...

Weight1.90258706 lb

SeriesCEM read heads

Product ClassSafety System

Center offset-2,5 ... +2,5 mm

Assured release distance Sarmax.20 mm (In conjunction w...

Switching hysteresis0,7 mm (In conjunction with...

Assured operating distance Saomin.2 mm (In conjunction wi...

Solenoid duty cycle100 %

Current consumption225 mA

Connection rating5,4 W

Operating voltage DC24 V DC -15% ... 10%

Adhesive force40 N -25% ... +25%

Locking force F1000 N

Cable lengthmax.25 m

Guard locking principleOpen-circuit current princip...

ConnectionPlug connector M8x1, 4-pin f...

Installation orientationAny

Housing materialDie-cast aluminum

MaterialSteel, nickel-plated

Switching frequencymax.1 Hz

Mechanical life1 x 10⁶

Read head materialPlastic (PPS)

Degree of protectionIP67

Ambient temperature-25 ... 50 °C

Mission time-

PFHD-

Category-

Performance Level-

For the approval acc. to UL the following applies-

Additional feature-

Repeat accuracy R-

Discrepancy time-

Output voltage-

Turn-on time-

Off-state current Ir-

Switching current-

Type of output-

Switching load-

Risk time according to EN 60947-5-3-

Safety class-

Degree of contamination (external, according to EN 60947-1)-

EMC protection requirements-

Rated impulse withstand voltage Uimp-

Rated insulation voltage Ui-

Fusing-

Solenoid operating voltage DC-

Utilization category acc. to EN 60947-5-2-

Test pulses-

Test-pulse interval-

Actuating force-

Extension of risk time according to EN 60947-5-3 per device-

Extraction force-

Overtravel-

Locking force Fmax-

Approach speed-

Retention force-

Locking force FZh-

Ready delay-

Shock and vibration resistance-

B10D-

Connection cross-section-

Switching voltage-

Short circuit protection according to IEC 60269-1-

Solenoid operating voltage-

Thermal rated current Ith-

Insertion depth-

Utilization category acc. to EN 60947-5-1-

Actuation frequency-

Number of door position NO contacts-

Number of guard lock monitoring positively driven contacts-

Number of door position NC contacts-

Switching principle-

Contact material-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

Center offset-

Assured release distance Sar-

Switching hysteresis-

Assured operating distance Sao-

Solenoid duty cycle100 %

Current consumption40 mA

Connection rating6 W

Operating voltage DC24 V DC -15% ... 15% Rev...

Adhesive force-

Locking force F-

Cable length-

Guard locking principleClosed-circuit current princ...

Connection2 plug connectors M12, 5 and...

Installation orientationAny

Housing materialDie-cast zinc

Material-

Switching frequencymax.0,5 Hz

Mechanical life1 x 10⁶

Read head material-

Degree of protectionIP67/IP69/IP69K (Screwed ti...

Ambient temperature-20 ... +55 °C

Mission time20 y

PFHD4.1 x 10 ⁻⁹

Category4

Performance LevelPL e

For the approval acc. to UL the following appliesOperation only with UL class...

Additional featureEscape release actuated by p...

Repeat accuracy R10 %

Discrepancy timemax.10 ms In acc. with EN ...

Output voltage0,8xUB ... UB V DC

Turn-on timemax.400 ms

Off-state current Irmax.0,25 mA

Switching current1 ... 50 mA

Type of outputp-switching, short circuit-p...

Switching load24V DC, class 2 (Alternativ...

Risk time according to EN 60947-5-3max.260 ms

Safety classIII

Degree of contamination (external, according to EN 60947-1)3

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Rated impulse withstand voltage Uimp0,5 kV

Rated insulation voltage Ui50 V

Fusing0,25 ... 8 A

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Test pulsesmax.1,0 ms (Applies for a l...

Test-pulse intervalmin.140 ms

Actuating force10 N

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Extraction force20 N

Overtravel5 mm

Locking force Fmax3900 N

Approach speedmax.20 m/min

Retention force20 N

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Ready delay8 s

Shock and vibration resistanceIn acc. with EN 60947-5-3

B10D-

Connection cross-section-

Switching voltage-

Short circuit protection according to IEC 60269-1-

Solenoid operating voltage-

Thermal rated current Ith-

Insertion depth-

Utilization category acc. to EN 60947-5-1-

Actuation frequency-

Number of door position NO contacts-

Number of guard lock monitoring positively driven contacts-

Number of door position NC contacts-

Switching principle-

Contact material-

100322
380 in stock
100322
Euchner

100322 Euchner - Safety switch STP with door monitoring contact, escape release

Weight1.24781492 lb

SeriesSTP

Product ClassSafety switch

Center offset-

Assured release distance Sar-

Switching hysteresis-

Assured operating distance Sao-

Solenoid duty cycle100 %

Current consumption-

Connection rating8 W

Operating voltage DC-

Adhesive force-

Locking force F-

Cable length-

Guard locking principleOpen-circuit current princip...

ConnectionM20 x 1.5

Installation orientationAny

Housing materialReinforced thermoplastic

Material-

Switching frequency-

Mechanical life1 x 10⁶

Read head material-

Degree of protectionIP67

Ambient temperature-20 ... 55 °C

Mission time-

PFHD-

Category-

Performance Level-

For the approval acc. to UL the following applies-

Additional feature-

Repeat accuracy R-

Discrepancy time-

Output voltage-

Turn-on time-

Off-state current Ir-

Switching current1 mA

Type of output-

Switching load-

Risk time according to EN 60947-5-3-

Safety class-

Degree of contamination (external, according to EN 60947-1)-

EMC protection requirements-

Rated impulse withstand voltage Uimp2,5 kV

Rated insulation voltage Ui50 V

Fusing-

Solenoid operating voltage DC-

Utilization category acc. to EN 60947-5-2-

Test pulses-

Test-pulse interval-

Actuating force35 N

Extension of risk time according to EN 60947-5-3 per device-

Extraction force30 N

Overtravel5 mm

Locking force Fmax2500 N

Approach speedmax.20 m/min

Retention force20 N

Locking force FZh2000 N

Ready delay-

Shock and vibration resistance-

B10D5 x 10⁶

Connection cross-section0,34 ... 1,5 mm²

Switching voltage12 V

Short circuit protection according to IEC 60269-14A gG

Solenoid operating voltage24 V -15% ... +10%

Thermal rated current Ith4 A

Insertion depth24,5 mm

Utilization category acc. to EN 60947-5-14A 50V

Actuation frequencymax.1200 1/h

Number of door position NO contacts1

Number of guard lock monitoring positively driven contacts2

Number of door position NC contacts1

Switching principleSlow-action switching contac...

Contact materialSilver alloy, gold flashed

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

FAQ

What is the price of 095170?
The price of 095170 on MQ Automation is $499.56. Order now.

Out if stock but available for backorder.

095170 Euchner - Read head CEM-A-LH10K-S3 with guard locking without guard lock monitoring with remanence

What can I help you find today?

Recommended parts