Product description

092750 Euchner - Electronic-Key adapter with USB interface

Product Details

  • Weight
    0.39462698 lb
  • Series
    EKS
  • Product Class
    Electronic-Key-System
  • Data protocol
    3964R via USB
  • LED indicator
    Operational
  • Ambient temperature
    0 ... 55 °C
  • Interface
    USB Full Speed (compatible with all USB versions)
  • Installation orientation
    On the front
  • Data rate
    9,6 ... 28,8 kbit/s
  • Power supply
    via USB
  • Current consumption
    max.100 mA
  • Mounting cut-out
    33x68 mm
  • Housing material
    Plastic (PA6 GF30, gray)
  • Connection
    USB type B socket
  • Degree of protection
    IP65/IP67
  • Cable length
    max.3 m USB

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 092750 on MQ Automation is $1,012.40. Order now.


About the product

Electronic-Key adapter with USB interface in housing G01;Read/write system;Power supply via USB interface;Type B socket connection;Electronic-Key adapter and electronics in one housing;Transfers the data from the Electronic-Key to a control system for processing;Connection to PC;Virtual serial COM port;Open communication commands at the lowest level;3964R protocol;Connection to the user software possible via ActiveX® module under Windows®;Very reliable retention of the Electronic-Key, even if there is heavy vibration;Especially recommended for setting up a programming station on a PC;Degree of protection: IP65/IP67 (installed);LED indicator


Manufacturer warranty

092750 Euchner

$1,012.40

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$1,012.40

$1,012.40 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 092750 with other products

Weight

Series

Product Class

Data protocol

LED indicator

Ambient temperature

Interface

Installation orientation

Data rate

Power supply

Current consumption

Mounting cut-out

Housing material

Connection

Degree of protection

Cable length

Additional feature

Data interface

Utilization category acc....

Utilization category acc....

Operating voltage DC

Connection cross-section

Switching current

Mounting method

Switching voltage

Number of read heads

Mission time

PFHD

Category

Performance Level

For the approval acc. to ...

Repeat accuracy R

Discrepancy time

Output voltage

Turn-on time

Off-state current Ir

Type of output

Switching load

Risk time according to EN...

Safety class

Degree of contamination (...

Solenoid duty cycle

EMC protection requiremen...

Rated impulse withstand v...

Rated insulation voltage ...

Connection rating

Fusing

Solenoid operating voltag...

Test pulses

Test-pulse interval

Actuating force

Extension of risk time ac...

Extraction force

Overtravel

Locking force Fmax

Approach speed

Retention force

Locking force FZh

Guard locking principle

Mechanical life

Switching frequency

Ready delay

Shock and vibration resis...

Selected product

092750
0 in stock
092750
Euchner

092750 Euchner - Electronic-Key adapter with USB interface

Weight0.39462698 lb

SeriesEKS

Product ClassElectronic-Key-System

Data protocol3964R via USB

LED indicatorOperational

Ambient temperature0 ... 55 °C

InterfaceUSB Full Speed (compatible w...

Installation orientationOn the front

Data rate9,6 ... 28,8 kbit/s

Power supplyvia USB

Current consumptionmax.100 mA

Mounting cut-out33x68 mm

Housing materialPlastic (PA6 GF30, gray)

ConnectionUSB type B socket

Degree of protectionIP65/IP67

Cable lengthmax.3 m USB

Additional feature-

Data interface-

Utilization category acc. to EN 60947-5-1-

Utilization category acc. to EN 60947-5-2-

Operating voltage DC-

Connection cross-section-

Switching current-

Mounting method-

Switching voltage-

Number of read heads-

Mission time-

PFHD-

Category-

Performance Level-

For the approval acc. to UL the following applies-

Repeat accuracy R-

Discrepancy time-

Output voltage-

Turn-on time-

Off-state current Ir-

Type of output-

Switching load-

Risk time according to EN 60947-5-3-

Safety class-

Degree of contamination (external, according to EN 60947-1)-

Solenoid duty cycle-

EMC protection requirements-

Rated impulse withstand voltage Uimp-

Rated insulation voltage Ui-

Connection rating-

Fusing-

Solenoid operating voltage DC-

Test pulses-

Test-pulse interval-

Actuating force-

Extension of risk time according to EN 60947-5-3 per device-

Extraction force-

Overtravel-

Locking force Fmax-

Approach speed-

Retention force-

Locking force FZh-

Guard locking principle-

Mechanical life-

Switching frequency-

Ready delay-

Shock and vibration resistance-

113645
1 in stock
113645
Euchner

113645 Euchner - Interface adapter EKS Light FSA modular (supports all operating states)

Weight0.46517482 lb

SeriesEKS Light

Product ClassElectronic-Key-System

Data protocol-

LED indicatorOperational

Ambient temperature0 ... 55 °C

Interface-

Installation orientation-

Data rate-

Power supply-

Current consumptionmax.70 mA

Mounting cut-out-

Housing materialPA6.6 gray

ConnectionPlug-in screw terminal

Degree of protection-

Cable length-

Additional feature35 Resistance in switched-...

Data interface4-bit parallel plus strobe, ...

Utilization category acc. to EN 60947-5-124V 50mA

Utilization category acc. to EN 60947-5-224V 50mA

Operating voltage DC9 ... 24 ... 28 V DC (For u...

Connection cross-section0,14 ... 2,5 mm²

Switching current1 ... 10 ... 50 mA High si...

Mounting methodMounting rail 35mm according...

Switching voltageU<sub>B</sub>-2 ... U<sub>B<...

Number of read headsmax.1

Mission time-

PFHD-

Category-

Performance Level-

For the approval acc. to UL the following applies-

Repeat accuracy R-

Discrepancy time-

Output voltage-

Turn-on time-

Off-state current Ir-

Type of output-

Switching load-

Risk time according to EN 60947-5-3-

Safety class-

Degree of contamination (external, according to EN 60947-1)-

Solenoid duty cycle-

EMC protection requirements-

Rated impulse withstand voltage Uimp-

Rated insulation voltage Ui-

Connection rating-

Fusing-

Solenoid operating voltage DC-

Test pulses-

Test-pulse interval-

Actuating force-

Extension of risk time according to EN 60947-5-3 per device-

Extraction force-

Overtravel-

Locking force Fmax-

Approach speed-

Retention force-

Locking force FZh-

Guard locking principle-

Mechanical life-

Switching frequency-

Ready delay-

Shock and vibration resistance-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

Data protocol-

LED indicator-

Ambient temperature-20 ... +55 °C

Interface-

Installation orientationAny

Data rate-

Power supply-

Current consumption40 mA

Mounting cut-out-

Housing materialDie-cast zinc

Connection2 plug connectors M12, 5 and...

Degree of protectionIP67/IP69/IP69K (Screwed ti...

Cable length-

Additional featureEscape release actuated by p...

Data interface-

Utilization category acc. to EN 60947-5-1-

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Operating voltage DC24 V DC -15% ... 15% Rev...

Connection cross-section-

Switching current1 ... 50 mA

Mounting method-

Switching voltage-

Number of read heads-

Mission time20 y

PFHD4.1 x 10 ⁻⁹

Category4

Performance LevelPL e

For the approval acc. to UL the following appliesOperation only with UL class...

Repeat accuracy R10 %

Discrepancy timemax.10 ms In acc. with EN ...

Output voltage0,8xUB ... UB V DC

Turn-on timemax.400 ms

Off-state current Irmax.0,25 mA

Type of outputp-switching, short circuit-p...

Switching load24V DC, class 2 (Alternativ...

Risk time according to EN 60947-5-3max.260 ms

Safety classIII

Degree of contamination (external, according to EN 60947-1)3

Solenoid duty cycle100 %

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Rated impulse withstand voltage Uimp0,5 kV

Rated insulation voltage Ui50 V

Connection rating6 W

Fusing0,25 ... 8 A

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Test pulsesmax.1,0 ms (Applies for a l...

Test-pulse intervalmin.140 ms

Actuating force10 N

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Extraction force20 N

Overtravel5 mm

Locking force Fmax3900 N

Approach speedmax.20 m/min

Retention force20 N

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Guard locking principleClosed-circuit current princ...

Mechanical life1 x 10⁶

Switching frequencymax.0,5 Hz

Ready delay8 s

Shock and vibration resistanceIn acc. with EN 60947-5-3

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 092750?
The price of 092750 on MQ Automation is $1,012.40. Order now.

Out if stock but available for backorder.

092750 Euchner - Electronic-Key adapter with USB interface

What can I help you find today?

Recommended parts