091458 Euchner Safety Proximity Sensors
Part#:091458
Alt. Part#:CES-A-C5H-01
Manufacturer:Euchner
Category:Safety Proximity Sensors
Product Lifecycle:Active
Product description
091458 Euchner - Non-contact safety switch CES-A-C5...
Product Details
- Weight 0.78043548 lb
- Series CES-A-.5
- Product Class Safety System
- Assured operating distance Sao min.15 mm (Applies for surface mounting on aluminum)
- Assured release distance Sar max.58 mm
- Operating distance 22 mm (Applies on surface mounting on aluminum; in a non-metallic environment the typical operating distance increases to 30 mm.)
- Switching hysteresis min.1 mm (Applies for surface mounting on aluminum)
- Distance s, actuator min.6 mm
- Diagnostic Coverage (DC) 99 %
- Mission time 20 y
- PFHD 3.7 x 10⁻⁹
- Repeat accuracy R max.10 %
- Performance Level PL e
- Category 4 (Category 4 according to EN ISO 13849-1 for monitoring short circuits of safety outputs. A short circuit of LA and LB must be detected by external pulsing or must be excluded by laying the cable with protection.)
- For the approval acc. to UL the following applies Operation only with UL class 2 power supply, or equivalent measures
- LED indicator Status - LED
- Discrepancy time max.120 ms
- Rated conditional short-circuit current max.100 A
- Power supply output load 24 V DC 18 ... 27 V DC
- Switching load max. DC 24 V, class 2
- Utilization category acc. to EN 60947-5-2 24V 400mA
- Output current 1 ... 400 mA
- Degree of contamination (external, according to EN 60947-1) 3
- Type of output Semiconductor outputs, p-switching, short circuit-proof, electrically decoupled (To ensure safety, both safety outputs (LA and LB) must be evaluated.)
- EMC protection requirements In acc. with EN 60947-5-3
- Output voltage U(+LA) - 1,5 ... U(+LA) V DC
- Rated impulse withstand voltage Uimp 1,5 kV
- Rated insulation voltage Ui 300 V (Tested by employers' liability insurance association up to 75 V.)
- Fusing 0,25 ... 8 A
- Current consumption 80 mA
- Operating voltage DC 18 ... 24 ... 27 V DC Regulated, residual ripple < 5 %
- Dwell time min.0,5 s (The dwell time of an actuator inside and outside the operating distance must be at least 0.5 s to ensure reliable detection of internal faults in the evaluation unit (self-monitoring).)
- Connection M12 plug connector, 8-pin, screen can be applied
- Switching frequency max.1 Hz
- Reaction time max.180 ms (Corresponds to the risk time according to EN 60947-5-3. This is the maximum switch-off delay for the safety outputs following removal of the actuator.)
- Tightening torque max.0,6 Nm
- Dimensions According to EN 60947-5-2: (LxWxH) 131x40x40
- Ready delay max.3 s (After the operating voltage is switched on, the semiconductor outputs are switched off and the monitoring outputs are set LOW during the ready delay.)
- Installation orientation Any
- Housing material Plastic, PBT
- Degree of protection IP65/IP67
- Mounting distance min.80 mm
- Weight 0,4 kg
- Ambient temperature -20 ... +55 °C
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 091458 on MQ Automation is $494.92. Order now.
About the product
Safety switch with integrated evaluation electronics;Pulsed signals can be switched;2 safety outputs (semiconductor outputs);Category 4 / PL e according to EN ISO 13849-1;Unicode
Manufacturer warranty
091458 Euchner
$494.92
Your price can be lower.
Log in or Create account to check your discount
Select Qty:
$494.92
$494.92 each
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Manufacturer warranty
Got Questions? We've Got Answers!
Need more details?
Feel free to chat with us
Compare 091458 with other products
Weight
Series
Product Class
Assured operating distanc...
Assured release distance ...
Operating distance
Switching hysteresis
Distance s, actuator
Diagnostic Coverage (DC)
Mission time
PFHD
Repeat accuracy R
Performance Level
Category
For the approval acc. to ...
LED indicator
Discrepancy time
Rated conditional short-c...
Power supply output load
Switching load
Utilization category acc....
Output current
Degree of contamination (...
Type of output
EMC protection requiremen...
Output voltage
Rated impulse withstand v...
Rated insulation voltage ...
Fusing
Current consumption
Operating voltage DC
Dwell time
Connection
Switching frequency
Reaction time
Tightening torque
Dimensions
Ready delay
Installation orientation
Housing material
Degree of protection
Mounting distance
Ambient temperature
Additional feature
Off-state current Ir
Test-pulse interval
Test pulses
Switching current
Turn-on time
Risk time according to EN...
Safety class
Extension of risk time ac...
Mounting method
Shock and vibration resis...
Cable ambient temperature...
Cable ambient temperature...
Dynamic bending radius
Material
Static bending radius
Selected product
Weight0.78043548 lb
SeriesCES-A-.5
Product ClassSafety System
Assured operating distance Saomin.15 mm (Applies for surf...
Assured release distance Sarmax.58 mm
Operating distance22 mm (Applies on surface m...
Switching hysteresismin.1 mm (Applies for surfa...
Distance s, actuatormin.6 mm
Diagnostic Coverage (DC)99 %
Mission time20 y
PFHD3.7 x 10⁻⁹
Repeat accuracy Rmax.10 %
Performance LevelPL e
Category4 (Category 4 according to...
For the approval acc. to UL the following appliesOperation only with UL class...
LED indicatorStatus - LED
Discrepancy timemax.120 ms
Rated conditional short-circuit currentmax.100 A
Power supply output load24 V DC 18 ... 27 V DC
Switching loadmax. DC 24 V, class 2
Utilization category acc. to EN 60947-5-224V 400mA
Output current1 ... 400 mA
Degree of contamination (external, according to EN 60947-1)3
Type of outputSemiconductor outputs, p-swi...
EMC protection requirementsIn acc. with EN 60947-5-3
Output voltageU(+LA) - 1,5 ... U(+LA) V D...
Rated impulse withstand voltage Uimp1,5 kV
Rated insulation voltage Ui300 V (Tested by employers...
Fusing0,25 ... 8 A
Current consumption80 mA
Operating voltage DC18 ... 24 ... 27 V DC Regu...
Dwell timemin.0,5 s (The dwell time o...
ConnectionM12 plug connector, 8-pin, s...
Switching frequencymax.1 Hz
Reaction timemax.180 ms (Corresponds to ...
Tightening torquemax.0,6 Nm
DimensionsAccording to EN 60947-5-2: (...
Ready delaymax.3 s (After the operatin...
Installation orientationAny
Housing materialPlastic, PBT
Degree of protectionIP65/IP67
Mounting distancemin.80 mm
Ambient temperature-20 ... +55 °C
Additional feature-
Off-state current Ir-
Test-pulse interval-
Test pulses-
Switching current-
Turn-on time-
Risk time according to EN 60947-5-3-
Safety class-
Extension of risk time according to EN 60947-5-3 per device-
Mounting method-
Shock and vibration resistance-
Cable ambient temperature (static)-
Cable ambient temperature (dynamic)-
Dynamic bending radius-
Material-
Static bending radius-
About the manufacturer

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.
Recently viewed products
Relevant products
FAQ
What is the price of 091458?
The price of 091458 on MQ Automation is $494.92. Order now.
Out if stock but available for backorder.
091458 Euchner - Non-contact safety switch CES-A-C5...
Similar products from: Safety Proximity Sensors
What can I help you find today?