090819 Euchner Safety Relays

090819 on MQ Automation
Euchner
  • 090819
  • 090819
  • 090819

Part#:090819

Alt. Part#:ESM-BT411

Manufacturer:Euchner

Category:Safety Relays

Product Lifecycle:Active

7 in stock

Mar 15, 2025

Product description

090819 Euchner - Safety relay ESM-BT.., 4 safety contacts, time-delay, cat. 4

Product Details

  • Weight
    0.56658734 lb
  • Series
    ESM
  • Product Class
    safety relay
  • Number of switching cycles
    max.500000 1/Jahr
  • PFHD
    8.84 x 10⁻⁸ (This value is dependent on the number of switching cycles and the switching current.)
  • Mission time
    20 y (This value is dependent on the number of switching cycles and the switching current.)
  • Performance Level
    PL e (This value is dependent on the number of switching cycles and the switching current.)
  • Category
    3 (This value is dependent on the number of switching cycles and the switching current.)
  • In compliance with
    EN ISO 13849-1: 2015; EN 62061: 2005 + AC: 2010 + A1: 2013 + A2: 2015; EN 50581: 2012 (RoHS)
  • Delay time
    1 ... 30 s
  • Breaking capacity according to UL
    8A 250V AC / 3A 24V DC per contact
  • Switching characteristics
    2 safety contacts non-delayed, 2 safety contacts time-delayed (Contact switching behavior: n.d.: non-delayed d.: delayed)
  • Fusing
    10A gG
  • Utilization category acc. to EN 60947-5-1
    3A, 250V
  • Cumulative current
    max.15 A For all contacts (Cumulative current at an ambient temperature of T= 20° C: 9A ;T= 30° C: 3A ; T= 40° C: 1A. If these currents are exceeded, a spacing of 5 mm between the devices must be observed.)
  • Switching current
    min.5 mA at 24V
  • Switching voltage
    max.24 V
  • Type of output
    Relay contacts floating and positively driven (redundant) (Positively driven relay according to EN 50205)
  • LED indicator
    4 status displays (green) for relays K1, K2, K3, K4
  • Control current
    190 mA
  • Test voltage
    2,5 kV
  • Control voltage
    24 V 18,6 ... 26 V Start button
  • Connection cross-section
    0,14 ... 2,5 mm² (Connection terminal (size))
  • Degree of contamination (external, according to EN 60947-1)
    2
  • Connection rating
    4,7 W
  • Rated supply frequency
    50 ... 60 Hz
  • Overvoltage category according to IEC EN 60664-1
    3
  • Rated impulse withstand voltage Uimp
    4 kV
  • Operating voltage
    24 V -10% ... +10% (All the electrical connections must either be isolated from the mains supply by a safety transformer according to EN 61558-2-6 with limited output voltage in the event of a fault, or by other equivalent isolation measures.)
  • Rated insulation voltage Ui
    250 V
  • Power consumption (apparent power)
    5,3 VA
  • Drop-out delay at 24V AC/DC
    max.20 ms Emergency stop
  • Number of NO contacts
    4
  • Length of control cable
    1000 m
  • Degree of protection
    IP20
  • Contact material
    AgSnO2
  • Connection
    Connection terminals
  • Mounting method
    Mounting rail 35mm according to DIN EN 60715 TH35
  • Weight
    0,25 kg
  • Ambient temperature
    -15 ... 40 °C
  • Housing material
    Polyamide PA6.6
  • Mechanical life
    10 x 10⁶

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 090819 on MQ Automation is $542.65. Order now.


About the product

Use up to category 4 according to EN ISO 13849-1;LED status indicators;1-channel or 2-channel control;4 redundant safety contacts of which 2 contacts time-delayed;Delay time range 1 s–30 s;Short circuit and earth fault/ground fault monitoring;24 V DC for ESM-BT411


This item can ship in 3-5 days!

Manufacturer warranty

090819 Euchner

$542.65

Your price can be lower.
Log in or Create account to check your discount

Stock:

7

Select Qty:

$542.65

$542.65 each

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 090819 with other products

Weight

Series

Product Class

Number of switching cycle...

PFHD

Mission time

Performance Level

Category

In compliance with

Delay time

Breaking capacity accordi...

Switching characteristics

Fusing

Utilization category acc....

Cumulative current

Switching current

Switching voltage

Type of output

LED indicator

Control current

Test voltage

Control voltage

Connection cross-section

Degree of contamination (...

Connection rating

Rated supply frequency

Overvoltage category acco...

Rated impulse withstand v...

Operating voltage

Rated insulation voltage ...

Power consumption (appare...

Drop-out delay at 24V AC/...

Number of NO contacts

Length of control cable

Degree of protection

Contact material

Connection

Mounting method

Ambient temperature

Housing material

Mechanical life

B10D

For the approval acc. to ...

Version

Operating current

Switching element

Repeat accuracy R

Detent mechanism

Discrepancy time

Off-state current Ir

Safety class

Turn-on time

Switching load

EMC protection requiremen...

Output voltage

Utilization category acc....

Current consumption

Operating voltage DC

Overtravel

Test-pulse interval

Extraction force

Test pulses

Actuating force

Installation orientation

Shock and vibration resis...

Approach speed

Switching frequency

Ready delay

Additional feature

Solenoid duty cycle

Short circuit protection ...

Solenoid operating voltag...

Thermal rated current Ith

Insertion depth

Locking force FZh

Retention force

Locking force Fmax

Actuation frequency

Guard locking principle

Number of door position N...

Switching principle

Number of guard lock moni...

Number of guard lock moni...

Selected product

090819
7 in stock
090819
Euchner

090819 Euchner - Safety relay ESM-BT.., 4 safety contacts, time-delay, cat. 4

Weight0.56658734 lb

SeriesESM

Product Classsafety relay

Number of switching cyclesmax.500000 1/Jahr

PFHD8.84 x 10⁻⁸ (This value is ...

Mission time20 y (This value is depend...

Performance LevelPL e (This value is depende...

Category3 (This value is dependent...

In compliance withEN ISO 13849-1: 2015; EN 620...

Delay time1 ... 30 s

Breaking capacity according to UL8A 250V AC / 3A 24V DC per c...

Switching characteristics2 safety contacts non-delaye...

Fusing10A gG

Utilization category acc. to EN 60947-5-13A, 250V

Cumulative currentmax.15 A For all contacts ...

Switching currentmin.5 mA at 24V

Switching voltagemax.24 V

Type of outputRelay contacts floating and ...

LED indicator4 status displays (green) fo...

Control current190 mA

Test voltage2,5 kV

Control voltage24 V 18,6 ... 26 V Start ...

Connection cross-section0,14 ... 2,5 mm² (Connectio...

Degree of contamination (external, according to EN 60947-1)2

Connection rating4,7 W

Rated supply frequency50 ... 60 Hz

Overvoltage category according to IEC EN 60664-13

Rated impulse withstand voltage Uimp4 kV

Operating voltage24 V -10% ... +10% (All t...

Rated insulation voltage Ui250 V

Power consumption (apparent power)5,3 VA

Drop-out delay at 24V AC/DCmax.20 ms Emergency stop

Number of NO contacts4

Length of control cable1000 m

Degree of protectionIP20

Contact materialAgSnO<sub>2</sub>

ConnectionConnection terminals

Mounting methodMounting rail 35mm according...

Ambient temperature-15 ... 40 °C

Housing materialPolyamide PA6.6

Mechanical life10 x 10⁶

B10D-

For the approval acc. to UL the following applies-

Version-

Operating current-

Switching element-

Repeat accuracy R-

Detent mechanism-

Discrepancy time-

Off-state current Ir-

Safety class-

Turn-on time-

Switching load-

EMC protection requirements-

Output voltage-

Utilization category acc. to EN 60947-5-2-

Current consumption-

Operating voltage DC-

Overtravel-

Test-pulse interval-

Extraction force-

Test pulses-

Actuating force-

Installation orientation-

Shock and vibration resistance-

Approach speed-

Switching frequency-

Ready delay-

Additional feature-

Solenoid duty cycle-

Short circuit protection according to IEC 60269-1-

Solenoid operating voltage-

Thermal rated current Ith-

Insertion depth-

Locking force FZh-

Retention force-

Locking force Fmax-

Actuation frequency-

Guard locking principle-

Number of door position NC contacts-

Switching principle-

Number of guard lock monitoring NO contacts-

Number of guard lock monitoring positively driven contacts-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

SeriesMGBS-P-I-AP

Product ClassSafety System

Number of switching cycles-

PFHD4.1 x 10 ⁻⁹

Mission time20 y

Performance LevelPL e

Category4

In compliance with-

Delay time-

Breaking capacity according to UL-

Switching characteristics-

Fusing0,25 ... 8 A

Utilization category acc. to EN 60947-5-1-

Cumulative current-

Switching current1 ... 150 mA

Switching voltage-

Type of output2 semiconductor outputs, p-s...

LED indicator-

Control current-

Test voltage-

Control voltage-

Connection cross-section-

Degree of contamination (external, according to EN 60947-1)3

Connection rating1 W

Rated supply frequency-

Overvoltage category according to IEC EN 60664-1-

Rated impulse withstand voltage Uimp0,5 kV

Operating voltage5 ... 24 V

Rated insulation voltage Ui50 V

Power consumption (apparent power)-

Drop-out delay at 24V AC/DC-

Number of NO contacts-

Length of control cable-

Degree of protectionIP65 (Screwed tight plug co...

Contact material-

Connection2 plug connectors M12, 5-pin

Mounting method-

Ambient temperature-20 ... +55 °C

Housing materialFiber glass reinforced therm...

Mechanical life1 x 10⁶

B10D0,13 x 10⁶

For the approval acc. to UL the following appliesOperation only with UL class...

VersionEmergency stop

Operating current1 ... 100 mA

Switching element2 pos. driven NC

Repeat accuracy R10 %

Detent mechanismSnap-in bolt

Discrepancy timemax.10 ms In acc. with EN ...

Off-state current Irmax.0,25 mA

Safety classIII

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Output voltage0 ... 1 V DC

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Current consumption40 mA

Operating voltage DC24 V DC -15% ... 15% Rev...

Overtravel5 mm

Test-pulse intervalmin.100 ms

Extraction force20 N

Test pulsesmax.0,3 ms (Applies for a l...

Actuating force10 N

Installation orientationDoor hinge DIN right

Shock and vibration resistanceIn acc. with EN 60947-5-3

Approach speedmax.20 m/min

Switching frequencymax.0,5 Hz

Ready delaymax.1 s

Additional feature-

Solenoid duty cycle-

Short circuit protection according to IEC 60269-1-

Solenoid operating voltage-

Thermal rated current Ith-

Insertion depth-

Locking force FZh-

Retention force-

Locking force Fmax-

Actuation frequency-

Guard locking principle-

Number of door position NC contacts-

Switching principle-

Number of guard lock monitoring NO contacts-

Number of guard lock monitoring positively driven contacts-

098827
1 in stock
098827
Euchner

098827 Euchner - Safety switch STP-TWIN with door monitoring contact

Weight1.68873892 lb

SeriesSTP

Product ClassSafety switch

Number of switching cycles-

PFHDDepending on external contro...

Mission time-

Performance LevelDepending on external contro...

CategoryDepending on external contro...

In compliance with-

Delay time-

Breaking capacity according to UL-

Switching characteristics-

Fusing-

Utilization category acc. to EN 60947-5-14A 230V

Cumulative current-

Switching current1 mA

Switching voltage12 V

Type of output-

LED indicator-

Control current-

Test voltage-

Control voltage-

Connection cross-section0,34 ... 1,5 mm²

Degree of contamination (external, according to EN 60947-1)-

Connection rating8 W

Rated supply frequency-

Overvoltage category according to IEC EN 60664-1-

Rated impulse withstand voltage Uimp2,5 kV

Operating voltage-

Rated insulation voltage Ui250 V

Power consumption (apparent power)-

Drop-out delay at 24V AC/DC-

Number of NO contacts-

Length of control cable-

Degree of protectionIP67

Contact materialSilver alloy, gold flashed

ConnectionM20 x 1.5

Mounting method-

Ambient temperature-20 ... 55 °C

Housing materialReinforced thermoplastic

Mechanical life1 x 10⁶

B10D5 x 10⁶

For the approval acc. to UL the following applies-

Version-

Operating current-

Switching element-

Repeat accuracy R-

Detent mechanism-

Discrepancy time-

Off-state current Ir-

Safety class-

Turn-on time-

Switching load-

EMC protection requirements-

Output voltage-

Utilization category acc. to EN 60947-5-2-

Current consumption-

Operating voltage DC-

Overtravel5 mm

Test-pulse interval-

Extraction force30 N

Test pulses-

Actuating force35 N

Installation orientationAny

Shock and vibration resistance-

Approach speedmax.20 m/min

Switching frequency-

Ready delay-

Additional featureWith mechanical key release ...

Solenoid duty cycle100 %

Short circuit protection according to IEC 60269-14A gG

Solenoid operating voltage24 V -15% ... +10%

Thermal rated current Ith4 A

Insertion depth24,5 mm

Locking force FZh2000 N

Retention force20 N

Locking force Fmax2500 N

Actuation frequencymax.1200 1/h

Guard locking principleClosed-circuit current princ...

Number of door position NC contacts1

Switching principleSlow-action switching contac...

Number of guard lock monitoring NO contacts1

Number of guard lock monitoring positively driven contacts2

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 090819?
The price of 090819 on MQ Automation is $542.65. Order now.

Out if stock but available for backorder.

090819 Euchner - Safety relay ESM-BT.., 4 safety contacts, time-delay, cat. 4

What can I help you find today?

Recommended parts