090077 Euchner Safety Relays

090077 on MQ Automation
Euchner
  • 090077
  • 090077

Part#:090077

Alt. Part#:ESM-BT411-20S

Manufacturer:Euchner

Category:Safety Relays

Product Lifecycle:Active

Product description

090077 Euchner - Safety relay ESM-BT.., 4 safety contacts, time-delay, cat. 4

Product Details

  • Weight
    0.5621781 lb
  • Series
    ESM
  • Product Class
    safety relay
  • Mission time
    20 y (This value is dependent on the number of switching cycles and the switching current.)
  • Number of switching cycles
    max.500000 1/Jahr
  • PFHD
    8.84 x 10⁻⁸ (This value is dependent on the number of switching cycles and the switching current.)
  • Performance Level
    PL e (This value is dependent on the number of switching cycles and the switching current.)
  • Category
    3 (This value is dependent on the number of switching cycles and the switching current.)
  • In compliance with
    EN ISO 13849-1: 2015; EN 62061: 2005 + AC: 2010 + A1: 2013 + A2: 2015; EN 50581: 2012 (RoHS)
  • Utilization category acc. to EN 60947-5-1
    3A, 250V
  • Delay time
    2 s
  • Switching characteristics
    2 safety contacts non-delayed, 2 safety contacts time-delayed (Contact switching behavior: n.d.: non-delayed d.: delayed)
  • Fusing
    10A gG
  • Switching current
    min.5 mA at 24V
  • Switching voltage
    max.250 V
  • Cumulative current
    max.15 A For all contacts (Cumulative current at an ambient temperature of T= 20° C: 9A ;T= 30° C: 3A ; T= 40° C: 1A. If these currents are exceeded, a spacing of 5 mm between the devices must be observed.)
  • LED indicator
    4 status displays (green) for relays K1, K2, K3, K4
  • Type of output
    Relay contacts positively driven (redundant) (Positively driven relay according to EN 50205)
  • Control current
    190 mA
  • Test voltage
    2,5 kV
  • Control voltage
    24 V 18,6 ... 26 V Start button
  • Degree of contamination (external, according to EN 60947-1)
    2
  • Connection cross-section
    0,14 ... 2,5 mm² (Connection terminal (size))
  • Rated supply frequency
    50 ... 60 Hz
  • Connection rating
    4,7 W
  • Overvoltage category according to IEC EN 60664-1
    3
  • Rated impulse withstand voltage Uimp
    4 kV
  • Rated insulation voltage Ui
    250 V
  • Drop-out delay at 24V AC/DC
    max.20 ms Emergency stop
  • Power consumption (apparent power)
    5,3 VA
  • Operating voltage
    24 V -10% ... +10% (All the electrical connections must either be isolated from the mains supply by a safety transformer according to EN 61558-2-6 with limited output voltage in the event of a fault, or by other equivalent isolation measures.)
  • Number of safety contacts
    4
  • Mounting method
    Mounting rail 35mm according to DIN EN 60715 TH35
  • Length of control cable
    1000 m
  • Connection
    Connection terminals
  • Degree of protection
    IP20
  • Ambient temperature
    -15 ... 40 °C
  • Mechanical life
    10 x 10⁶
  • Housing material
    Polyamide PA6.6
  • Weight
    0,25 kg
  • Contact material
    AgSnO2

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 090077 on MQ Automation is $543.75. Order now.


About the product

Use up to category 4 according to EN ISO 13849-1;LED status indicators;1-channel or 2-channel control;4 redundant safety contacts of which 2 contacts time-delayed;Time delay 2 s;Short circuit and earth fault/ground fault monitoring


Manufacturer warranty

090077 Euchner

$543.75

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$543.75

$543.75 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 090077 with other products

Weight

Series

Product Class

Mission time

Number of switching cycle...

PFHD

Performance Level

Category

In compliance with

Utilization category acc....

Delay time

Switching characteristics

Fusing

Switching current

Switching voltage

Cumulative current

LED indicator

Type of output

Control current

Test voltage

Control voltage

Degree of contamination (...

Connection cross-section

Rated supply frequency

Connection rating

Overvoltage category acco...

Rated impulse withstand v...

Rated insulation voltage ...

Drop-out delay at 24V AC/...

Power consumption (appare...

Operating voltage

Number of safety contacts

Mounting method

Length of control cable

Connection

Degree of protection

Ambient temperature

Mechanical life

Housing material

Contact material

B10D

For the approval acc. to ...

Version

Operating current

Switching element

Repeat accuracy R

Detent mechanism

Discrepancy time

Off-state current Ir

Safety class

Turn-on time

Switching load

EMC protection requiremen...

Output voltage

Utilization category acc....

Current consumption

Operating voltage DC

Overtravel

Test-pulse interval

Extraction force

Test pulses

Actuating force

Installation orientation

Shock and vibration resis...

Approach speed

Switching frequency

Ready delay

Additional feature

Solenoid duty cycle

Short circuit protection ...

Solenoid operating voltag...

Thermal rated current Ith

Insertion depth

Locking force FZh

Retention force

Locking force Fmax

Actuation frequency

Guard locking principle

Number of door position N...

Switching principle

Number of guard lock moni...

Number of guard lock moni...

Selected product

090077
0 in stock
090077
Euchner

090077 Euchner - Safety relay ESM-BT.., 4 safety contacts, time-delay, cat. 4

Weight0.5621781 lb

SeriesESM

Product Classsafety relay

Mission time20 y (This value is depend...

Number of switching cyclesmax.500000 1/Jahr

PFHD8.84 x 10⁻⁸ (This value is ...

Performance LevelPL e (This value is depende...

Category3 (This value is dependent...

In compliance withEN ISO 13849-1: 2015; EN 620...

Utilization category acc. to EN 60947-5-13A, 250V

Delay time2 s

Switching characteristics2 safety contacts non-delaye...

Fusing10A gG

Switching currentmin.5 mA at 24V

Switching voltagemax.250 V

Cumulative currentmax.15 A For all contacts ...

LED indicator4 status displays (green) fo...

Type of outputRelay contacts positively dr...

Control current190 mA

Test voltage2,5 kV

Control voltage24 V 18,6 ... 26 V Start ...

Degree of contamination (external, according to EN 60947-1)2

Connection cross-section0,14 ... 2,5 mm² (Connectio...

Rated supply frequency50 ... 60 Hz

Connection rating4,7 W

Overvoltage category according to IEC EN 60664-13

Rated impulse withstand voltage Uimp4 kV

Rated insulation voltage Ui250 V

Drop-out delay at 24V AC/DCmax.20 ms Emergency stop

Power consumption (apparent power)5,3 VA

Operating voltage24 V -10% ... +10% (All t...

Number of safety contacts4

Mounting methodMounting rail 35mm according...

Length of control cable1000 m

ConnectionConnection terminals

Degree of protectionIP20

Ambient temperature-15 ... 40 °C

Mechanical life10 x 10⁶

Housing materialPolyamide PA6.6

Contact materialAgSnO<sub>2</sub>

B10D-

For the approval acc. to UL the following applies-

Version-

Operating current-

Switching element-

Repeat accuracy R-

Detent mechanism-

Discrepancy time-

Off-state current Ir-

Safety class-

Turn-on time-

Switching load-

EMC protection requirements-

Output voltage-

Utilization category acc. to EN 60947-5-2-

Current consumption-

Operating voltage DC-

Overtravel-

Test-pulse interval-

Extraction force-

Test pulses-

Actuating force-

Installation orientation-

Shock and vibration resistance-

Approach speed-

Switching frequency-

Ready delay-

Additional feature-

Solenoid duty cycle-

Short circuit protection according to IEC 60269-1-

Solenoid operating voltage-

Thermal rated current Ith-

Insertion depth-

Locking force FZh-

Retention force-

Locking force Fmax-

Actuation frequency-

Guard locking principle-

Number of door position NC contacts-

Switching principle-

Number of guard lock monitoring NO contacts-

Number of guard lock monitoring positively driven contacts-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

SeriesMGBS-P-I-AP

Product ClassSafety System

Mission time20 y

Number of switching cycles-

PFHD4.1 x 10 ⁻⁹

Performance LevelPL e

Category4

In compliance with-

Utilization category acc. to EN 60947-5-1-

Delay time-

Switching characteristics-

Fusing0,25 ... 8 A

Switching current1 ... 150 mA

Switching voltage-

Cumulative current-

LED indicator-

Type of output2 semiconductor outputs, p-s...

Control current-

Test voltage-

Control voltage-

Degree of contamination (external, according to EN 60947-1)3

Connection cross-section-

Rated supply frequency-

Connection rating1 W

Overvoltage category according to IEC EN 60664-1-

Rated impulse withstand voltage Uimp0,5 kV

Rated insulation voltage Ui50 V

Drop-out delay at 24V AC/DC-

Power consumption (apparent power)-

Operating voltage5 ... 24 V

Number of safety contacts-

Mounting method-

Length of control cable-

Connection2 plug connectors M12, 5-pin

Degree of protectionIP65 (Screwed tight plug co...

Ambient temperature-20 ... +55 °C

Mechanical life1 x 10⁶

Housing materialFiber glass reinforced therm...

Contact material-

B10D0,13 x 10⁶

For the approval acc. to UL the following appliesOperation only with UL class...

VersionEmergency stop

Operating current1 ... 100 mA

Switching element2 pos. driven NC

Repeat accuracy R10 %

Detent mechanismSnap-in bolt

Discrepancy timemax.10 ms In acc. with EN ...

Off-state current Irmax.0,25 mA

Safety classIII

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Output voltage0 ... 1 V DC

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Current consumption40 mA

Operating voltage DC24 V DC -15% ... 15% Rev...

Overtravel5 mm

Test-pulse intervalmin.100 ms

Extraction force20 N

Test pulsesmax.0,3 ms (Applies for a l...

Actuating force10 N

Installation orientationDoor hinge DIN right

Shock and vibration resistanceIn acc. with EN 60947-5-3

Approach speedmax.20 m/min

Switching frequencymax.0,5 Hz

Ready delaymax.1 s

Additional feature-

Solenoid duty cycle-

Short circuit protection according to IEC 60269-1-

Solenoid operating voltage-

Thermal rated current Ith-

Insertion depth-

Locking force FZh-

Retention force-

Locking force Fmax-

Actuation frequency-

Guard locking principle-

Number of door position NC contacts-

Switching principle-

Number of guard lock monitoring NO contacts-

Number of guard lock monitoring positively driven contacts-

098827
1 in stock
098827
Euchner

098827 Euchner - Safety switch STP-TWIN with door monitoring contact

Weight1.68873892 lb

SeriesSTP

Product ClassSafety switch

Mission time-

Number of switching cycles-

PFHDDepending on external contro...

Performance LevelDepending on external contro...

CategoryDepending on external contro...

In compliance with-

Utilization category acc. to EN 60947-5-14A 230V

Delay time-

Switching characteristics-

Fusing-

Switching current1 mA

Switching voltage12 V

Cumulative current-

LED indicator-

Type of output-

Control current-

Test voltage-

Control voltage-

Degree of contamination (external, according to EN 60947-1)-

Connection cross-section0,34 ... 1,5 mm²

Rated supply frequency-

Connection rating8 W

Overvoltage category according to IEC EN 60664-1-

Rated impulse withstand voltage Uimp2,5 kV

Rated insulation voltage Ui250 V

Drop-out delay at 24V AC/DC-

Power consumption (apparent power)-

Operating voltage-

Number of safety contacts-

Mounting method-

Length of control cable-

ConnectionM20 x 1.5

Degree of protectionIP67

Ambient temperature-20 ... 55 °C

Mechanical life1 x 10⁶

Housing materialReinforced thermoplastic

Contact materialSilver alloy, gold flashed

B10D5 x 10⁶

For the approval acc. to UL the following applies-

Version-

Operating current-

Switching element-

Repeat accuracy R-

Detent mechanism-

Discrepancy time-

Off-state current Ir-

Safety class-

Turn-on time-

Switching load-

EMC protection requirements-

Output voltage-

Utilization category acc. to EN 60947-5-2-

Current consumption-

Operating voltage DC-

Overtravel5 mm

Test-pulse interval-

Extraction force30 N

Test pulses-

Actuating force35 N

Installation orientationAny

Shock and vibration resistance-

Approach speedmax.20 m/min

Switching frequency-

Ready delay-

Additional featureWith mechanical key release ...

Solenoid duty cycle100 %

Short circuit protection according to IEC 60269-14A gG

Solenoid operating voltage24 V -15% ... +10%

Thermal rated current Ith4 A

Insertion depth24,5 mm

Locking force FZh2000 N

Retention force20 N

Locking force Fmax2500 N

Actuation frequencymax.1200 1/h

Guard locking principleClosed-circuit current princ...

Number of door position NC contacts1

Switching principleSlow-action switching contac...

Number of guard lock monitoring NO contacts1

Number of guard lock monitoring positively driven contacts2

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 090077?
The price of 090077 on MQ Automation is $543.75. Order now.

Out if stock but available for backorder.

090077 Euchner - Safety relay ESM-BT.., 4 safety contacts, time-delay, cat. 4

What can I help you find today?

Recommended parts