Part#:087413

Alt. Part#:ESM-BA303

Manufacturer:Euchner

Category:Safety Relays

Product Lifecycle:Active

Product description

087413 Euchner - Basic device ESM-BA3.., 3 safety contacts, 1 auxiliary contact, cat. 4

Product Details

  • Weight
    0.65697676 lb
  • Series
    ESM
  • Product Class
    safety relay
  • Category
    4 (This value is dependent on the number of switching cycles and the switching current.)
  • Mission time
    20 y (This value is dependent on the number of switching cycles and the switching current.)
  • PFHD
    1.2 x 10⁻⁸ (This value is dependent on the number of switching cycles and the switching current.)
  • Number of switching cycles
    max.100000 1/Jahr
  • Performance Level
    PL e (This value is dependent on the number of switching cycles and the switching current.)
  • Fusing
    10A gG
  • Cumulative current
    max.15 A For all contacts (If several ESM-BA3.. devices are closely spaced under load, the max. cumulative current at the ambient temperature of T=20°C is 9A; at T=30°C is 3A; at T=40°C is 1A. If these currents are exceeded, a spacing of 5mm between th
  • In compliance with
    EN ISO 13849-1: 2015; EN 62061: 2005 + AC: 2010 + A1: 2013 + A2: 2015; EN 50581: 2012 (RoHS)
  • Switching current
    min.5 mA at 24V
  • Switching voltage
    max.24 V
  • Breaking capacity (VA)
    max.500 VA
  • Utilization category acc. to EN 60947-5-1
    2A ohmic load, 250V
  • Breaking capacity according to UL
    2A 250V AC / 2A 24V DC per contact
  • Control current
    60 mA
  • LED indicator
    2 status displays (green) for relays K1 and K2
  • Control voltage
    24 V 18,6 ... 26 V Start button
  • Type of output
    Relay contacts, floating
  • Test voltage
    2,5 kV
  • Connection cross-section
    0,14 ... 2,5 mm² (Connection terminal (size))
  • Overvoltage category according to IEC EN 60664-1
    3
  • Rated insulation voltage Ui
    250 V
  • Degree of contamination (external, according to EN 60947-1)
    2
  • Rated supply frequency
    50 ... 60 Hz
  • Rated impulse withstand voltage Uimp
    4 kV
  • Number of auxiliary contacts
    1
  • Power consumption (apparent power)
    6,9 VA
  • Operating voltage
    230 V -10% ... +10%
  • Number of safety contacts
    3
  • Ambient temperature
    -15 ... 40 °C (If several ESM-BA3.. devices are closely spaced under load, the max. cumulative current at the ambient temperature of T=20°C is 9A; at T=30°C is 3A; at T=40°C is 1A. If these currents are exceeded, a spacing of 5mm between the devices must
  • Degree of protection
    IP20
  • Connection
    Connection terminals
  • Mechanical life
    10 x 10⁶
  • Mounting method
    Mounting rail 35mm according to DIN EN 60715 TH35
  • Contact material
    AgSnO2
  • Length of control cable
    1000 m
  • Weight
    0,23 kg
  • Housing material
    Polyamide PA6.6

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 087413 on MQ Automation is $375.87. Order now.


About the product

ESM-BA.. Use up to category 4 according to EN ISO 13849-1;LED status indicators;1-channel or 2-channel control;3 redundant safety contacts;1 auxiliary contact (monitoring contact);Short circuit and earth fault/ground fault monitoring


Manufacturer warranty

087413 Euchner

$375.87

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$375.87

$375.87 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 087413 with other products

Weight

Series

Product Class

Category

Mission time

PFHD

Number of switching cycle...

Performance Level

Fusing

Cumulative current

In compliance with

Switching current

Switching voltage

Breaking capacity (VA)

Utilization category acc....

Breaking capacity accordi...

Control current

LED indicator

Control voltage

Type of output

Test voltage

Connection cross-section

Overvoltage category acco...

Rated insulation voltage ...

Degree of contamination (...

Rated supply frequency

Rated impulse withstand v...

Number of auxiliary conta...

Power consumption (appare...

Operating voltage

Number of safety contacts

Ambient temperature

Degree of protection

Connection

Mechanical life

Mounting method

Contact material

Length of control cable

Housing material

Overtravel

B10D

Additional feature

Solenoid duty cycle

Connection rating

Short circuit protection ...

Solenoid operating voltag...

Thermal rated current Ith

Insertion depth

Actuating force

Locking force FZh

Retention force

Extraction force

Locking force Fmax

Actuation frequency

Guard locking principle

Approach speed

Installation orientation

Number of door position N...

Switching principle

Number of guard lock moni...

Number of guard lock moni...

For the approval acc. to ...

Version

Operating current

Switching element

Repeat accuracy R

Detent mechanism

Discrepancy time

Off-state current Ir

Safety class

Turn-on time

Switching load

EMC protection requiremen...

Output voltage

Utilization category acc....

Current consumption

Operating voltage DC

Test-pulse interval

Test pulses

Shock and vibration resis...

Switching frequency

Ready delay

Selected product

087413
0 in stock
087413
Euchner

087413 Euchner - Basic device ESM-BA3.., 3 safety contacts, 1 auxiliary contact, cat. 4

Weight0.65697676 lb

SeriesESM

Product Classsafety relay

Category4 (This value is dependent...

Mission time20 y (This value is depend...

PFHD1.2 x 10⁻⁸ (This value is d...

Number of switching cyclesmax.100000 1/Jahr

Performance LevelPL e (This value is depende...

Fusing10A gG

Cumulative currentmax.15 A For all contacts ...

In compliance withEN ISO 13849-1: 2015; EN 620...

Switching currentmin.5 mA at 24V

Switching voltagemax.24 V

Breaking capacity (VA)max.500 VA

Utilization category acc. to EN 60947-5-12A ohmic load, 250V

Breaking capacity according to UL2A 250V AC / 2A 24V DC per c...

Control current60 mA

LED indicator2 status displays (green) fo...

Control voltage24 V 18,6 ... 26 V Start ...

Type of outputRelay contacts, floating

Test voltage2,5 kV

Connection cross-section0,14 ... 2,5 mm² (Connectio...

Overvoltage category according to IEC EN 60664-13

Rated insulation voltage Ui250 V

Degree of contamination (external, according to EN 60947-1)2

Rated supply frequency50 ... 60 Hz

Rated impulse withstand voltage Uimp4 kV

Number of auxiliary contacts1

Power consumption (apparent power)6,9 VA

Operating voltage230 V -10% ... +10%

Number of safety contacts3

Ambient temperature-15 ... 40 °C (If several E...

Degree of protectionIP20

ConnectionConnection terminals

Mechanical life10 x 10⁶

Mounting methodMounting rail 35mm according...

Contact materialAgSnO<sub>2</sub>

Length of control cable1000 m

Housing materialPolyamide PA6.6

Overtravel-

B10D-

Additional feature-

Solenoid duty cycle-

Connection rating-

Short circuit protection according to IEC 60269-1-

Solenoid operating voltage-

Thermal rated current Ith-

Insertion depth-

Actuating force-

Locking force FZh-

Retention force-

Extraction force-

Locking force Fmax-

Actuation frequency-

Guard locking principle-

Approach speed-

Installation orientation-

Number of door position NC contacts-

Switching principle-

Number of guard lock monitoring NO contacts-

Number of guard lock monitoring positively driven contacts-

For the approval acc. to UL the following applies-

Version-

Operating current-

Switching element-

Repeat accuracy R-

Detent mechanism-

Discrepancy time-

Off-state current Ir-

Safety class-

Turn-on time-

Switching load-

EMC protection requirements-

Output voltage-

Utilization category acc. to EN 60947-5-2-

Current consumption-

Operating voltage DC-

Test-pulse interval-

Test pulses-

Shock and vibration resistance-

Switching frequency-

Ready delay-

098827
1 in stock
098827
Euchner

098827 Euchner - Safety switch STP-TWIN with door monitoring contact

Weight1.68873892 lb

SeriesSTP

Product ClassSafety switch

CategoryDepending on external contro...

Mission time-

PFHDDepending on external contro...

Number of switching cycles-

Performance LevelDepending on external contro...

Fusing-

Cumulative current-

In compliance with-

Switching current1 mA

Switching voltage12 V

Breaking capacity (VA)-

Utilization category acc. to EN 60947-5-14A 230V

Breaking capacity according to UL-

Control current-

LED indicator-

Control voltage-

Type of output-

Test voltage-

Connection cross-section0,34 ... 1,5 mm²

Overvoltage category according to IEC EN 60664-1-

Rated insulation voltage Ui250 V

Degree of contamination (external, according to EN 60947-1)-

Rated supply frequency-

Rated impulse withstand voltage Uimp2,5 kV

Number of auxiliary contacts-

Power consumption (apparent power)-

Operating voltage-

Number of safety contacts-

Ambient temperature-20 ... 55 °C

Degree of protectionIP67

ConnectionM20 x 1.5

Mechanical life1 x 10⁶

Mounting method-

Contact materialSilver alloy, gold flashed

Length of control cable-

Housing materialReinforced thermoplastic

Overtravel5 mm

B10D5 x 10⁶

Additional featureWith mechanical key release ...

Solenoid duty cycle100 %

Connection rating8 W

Short circuit protection according to IEC 60269-14A gG

Solenoid operating voltage24 V -15% ... +10%

Thermal rated current Ith4 A

Insertion depth24,5 mm

Actuating force35 N

Locking force FZh2000 N

Retention force20 N

Extraction force30 N

Locking force Fmax2500 N

Actuation frequencymax.1200 1/h

Guard locking principleClosed-circuit current princ...

Approach speedmax.20 m/min

Installation orientationAny

Number of door position NC contacts1

Switching principleSlow-action switching contac...

Number of guard lock monitoring NO contacts1

Number of guard lock monitoring positively driven contacts2

For the approval acc. to UL the following applies-

Version-

Operating current-

Switching element-

Repeat accuracy R-

Detent mechanism-

Discrepancy time-

Off-state current Ir-

Safety class-

Turn-on time-

Switching load-

EMC protection requirements-

Output voltage-

Utilization category acc. to EN 60947-5-2-

Current consumption-

Operating voltage DC-

Test-pulse interval-

Test pulses-

Shock and vibration resistance-

Switching frequency-

Ready delay-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

SeriesMGBS-P-I-AP

Product ClassSafety System

Category4

Mission time20 y

PFHD4.1 x 10 ⁻⁹

Number of switching cycles-

Performance LevelPL e

Fusing0,25 ... 8 A

Cumulative current-

In compliance with-

Switching current1 ... 150 mA

Switching voltage-

Breaking capacity (VA)-

Utilization category acc. to EN 60947-5-1-

Breaking capacity according to UL-

Control current-

LED indicator-

Control voltage-

Type of output2 semiconductor outputs, p-s...

Test voltage-

Connection cross-section-

Overvoltage category according to IEC EN 60664-1-

Rated insulation voltage Ui50 V

Degree of contamination (external, according to EN 60947-1)3

Rated supply frequency-

Rated impulse withstand voltage Uimp0,5 kV

Number of auxiliary contacts-

Power consumption (apparent power)-

Operating voltage5 ... 24 V

Number of safety contacts-

Ambient temperature-20 ... +55 °C

Degree of protectionIP65 (Screwed tight plug co...

Connection2 plug connectors M12, 5-pin

Mechanical life1 x 10⁶

Mounting method-

Contact material-

Length of control cable-

Housing materialFiber glass reinforced therm...

Overtravel5 mm

B10D0,13 x 10⁶

Additional feature-

Solenoid duty cycle-

Connection rating1 W

Short circuit protection according to IEC 60269-1-

Solenoid operating voltage-

Thermal rated current Ith-

Insertion depth-

Actuating force10 N

Locking force FZh-

Retention force-

Extraction force20 N

Locking force Fmax-

Actuation frequency-

Guard locking principle-

Approach speedmax.20 m/min

Installation orientationDoor hinge DIN right

Number of door position NC contacts-

Switching principle-

Number of guard lock monitoring NO contacts-

Number of guard lock monitoring positively driven contacts-

For the approval acc. to UL the following appliesOperation only with UL class...

VersionEmergency stop

Operating current1 ... 100 mA

Switching element2 pos. driven NC

Repeat accuracy R10 %

Detent mechanismSnap-in bolt

Discrepancy timemax.10 ms In acc. with EN ...

Off-state current Irmax.0,25 mA

Safety classIII

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Output voltage0 ... 1 V DC

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Current consumption40 mA

Operating voltage DC24 V DC -15% ... 15% Rev...

Test-pulse intervalmin.100 ms

Test pulsesmax.0,3 ms (Applies for a l...

Shock and vibration resistanceIn acc. with EN 60947-5-3

Switching frequencymax.0,5 Hz

Ready delaymax.1 s

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 087413?
The price of 087413 on MQ Automation is $375.87. Order now.

Out if stock but available for backorder.

087413 Euchner - Basic device ESM-BA3.., 3 safety contacts, 1 auxiliary contact, cat. 4

What can I help you find today?

Recommended parts