086280 Euchner Electronic Components


Part#:086280
Manufacturer:Euchner
Category:Electronic Components
Product Lifecycle:Active
Product description
Inductive single limit switches design ENA
Product Details
- Additional feature Yes
- Switching hysteresis max.0,5 mm
- LED indicator No
- Rated operating distance Sn 5 mm
- Off-state current Ir max.0,001 mA
- Voltage drop Ud max.2,5 V
- Repeat accuracy R max.5 %
- Reverse polarity protection Yes
- Connection cross-section 0,34 ... 1,5 mm²
- Assured operating distance Sa 0 ... 4 mm
- EMC protection requirements IEC 60947-5-2
- No-load current I0 max.15 mA
- Rated insulation voltage Ui 60 V
- Utilization category acc. to EN 60947-5-2 DC-13
- Short circuit and overload protection, pulsed Yes
- Ambient temperature -25 ... 70 °C
- Degree of protection IP67
- Type of output PNP
- Design Housing according to DIN 43693
- Operating voltage DC 10 ... 55 V DC
- Weight 0,25 kg
- Switching frequency max.500 Hz
- Installation orientation Any
- Rated operating current Ie max.250 mA
- Switching principle NO + NC
- Connection M16 x 1.5
- Material PBT
- Housing material Die-cast aluminum, anodized
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
086280 Euchner
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Manufacturer warranty
Got Questions? We've Got Answers!
Need more details?
Feel free to chat with us
Compare 086280 with other products
Additional feature
Switching hysteresis
LED indicator
Rated operating distance ...
Off-state current Ir
Voltage drop Ud
Repeat accuracy R
Reverse polarity protecti...
Connection cross-section
Assured operating distanc...
EMC protection requiremen...
No-load current I0
Rated insulation voltage ...
Utilization category acc....
Short circuit and overloa...
Ambient temperature
Degree of protection
Type of output
Design
Operating voltage DC
Weight
Switching frequency
Installation orientation
Rated operating current I...
Switching principle
Connection
Material
Housing material
Series
Product Class
Assured operating distanc...
Assured release distance ...
Operating distance
Mission time
PFHD
For the approval acc. to ...
Performance Level
Category
Discrepancy time
Rated conditional short-c...
Test-pulse interval
Test pulses
Switching current
Output voltage
Turn-on time
Risk time according to EN...
Safety class
Degree of contamination (...
Rated impulse withstand v...
Fusing
Extension of risk time ac...
Current consumption
Ready delay
Tightening torque
Mounting method
Shock and vibration resis...
Mounting distance
Cable ambient temperature...
Cable ambient temperature...
Dynamic bending radius
Static bending radius
Switching load
Solenoid duty cycle
Connection rating
Solenoid operating voltag...
Actuating force
Extraction force
Overtravel
Locking force Fmax
Approach speed
Retention force
Locking force FZh
Guard locking principle
Mechanical life
Selected product
Additional featureYes
Switching hysteresismax.0,5 mm
LED indicatorNo
Rated operating distance Sn5 mm
Off-state current Irmax.0,001 mA
Voltage drop Udmax.2,5 V
Repeat accuracy Rmax.5 %
Reverse polarity protectionYes
Connection cross-section0,34 ... 1,5 mm²
Assured operating distance Sa0 ... 4 mm
EMC protection requirementsIEC 60947-5-2
No-load current I0max.15 mA
Rated insulation voltage Ui60 V
Utilization category acc. to EN 60947-5-2DC-13
Short circuit and overload protection, pulsedYes
Ambient temperature-25 ... 70 °C
Degree of protectionIP67
Type of outputPNP
DesignHousing according to DIN 436...
Operating voltage DC10 ... 55 V DC
Weight0,25 kg
Switching frequencymax.500 Hz
Installation orientationAny
Rated operating current Iemax.250 mA
Switching principleNO + NC
ConnectionM16 x 1.5
MaterialPBT
Housing materialDie-cast aluminum, anodized
Series-
Product Class-
Assured operating distance Sao-
Assured release distance Sar-
Operating distance-
Mission time-
PFHD-
For the approval acc. to UL the following applies-
Performance Level-
Category-
Discrepancy time-
Rated conditional short-circuit current-
Test-pulse interval-
Test pulses-
Switching current-
Output voltage-
Turn-on time-
Risk time according to EN 60947-5-3-
Safety class-
Degree of contamination (external, according to EN 60947-1)-
Rated impulse withstand voltage Uimp-
Fusing-
Extension of risk time according to EN 60947-5-3 per device-
Current consumption-
Ready delay-
Tightening torque-
Mounting method-
Shock and vibration resistance-
Mounting distance-
Cable ambient temperature (static)-
Cable ambient temperature (dynamic)-
Dynamic bending radius-
Static bending radius-
Switching load-
Solenoid duty cycle-
Connection rating-
Solenoid operating voltage DC-
Actuating force-
Extraction force-
Overtravel-
Locking force Fmax-
Approach speed-
Retention force-
Locking force FZh-
Guard locking principle-
Mechanical life-
About the manufacturer

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.
Recently viewed products
Relevant products
FAQ
Out if stock but available for backorder.
Inductive single limit switches design ENA
Similar products from: Electronic Components
What can I help you find today?