086030 Euchner Limit Switches

086030 on MQ Automation
Euchner

Part#:086030

Alt. Part#:RGBF04X16-772L-M

Manufacturer:Euchner

Category:Limit Switches

Product Lifecycle:Active

Product description

086030 Euchner - MULTIPLE LIMIT SWITCH

Product Details

  • Weight
    1.82574 lb
  • Additional information
    (Switching elements with 5mm operating distance (16mm proximity switch spacing) are supplied with two different oscillator frequencies to avoid mutual interference. Multiple limit switches must therefore be assembled alternately with these switching eleme
  • Switching hysteresis
    max.0,5 mm
  • Assured operating distance Sa
    0 ... 4 mm (Dimension only applies for steel (ST37) and for EUCHNER trip dogs of series UX.. / GX..)
  • Repeat accuracy R
    max.5 %
  • Rated operating distance Sn
    5 mm
  • LED indicator
    Yes
  • Connection cross-section
    0,34 ... 1,5 mm² (Screw terminals)
  • Voltage drop Ud
    max.2,5 V
  • No-load current I0
    max.15 mA
  • Type of output
    PNP
  • Off-state current Ir
    max.0,001 mA
  • Reverse polarity protection
    Yes
  • EMC protection requirements
    EN IEC 60947-5-2
  • Residual ripple
    max.10 %
  • Rated insulation voltage Ui
    60 V
  • Short circuit and overload protection, pulsed
    Yes
  • Utilization category acc. to EN 60947-5-2
    DC-13 (The output is to be protected with a free-wheeling diode for inductive loads.)
  • Rated operating current Ie
    250 mA
  • Number of NC contacts/NO contacts
    4
  • Operating voltage
    10 ... 55 V
  • Connection
    M25 x 1.5
  • Switching frequency
    max.500 Hz
  • Number of switching elements
    4
  • Proximity switch spacing
    16 mm
  • Weight
    1,1 kg Connection terminals
  • Ambient temperature
    -25 ... 70 °C
  • Material
    PBT
  • Housing material
    Die-cast aluminum
  • Switching principle
    NO + NC
  • Design
    Upright, according to DIN 43697
  • Degree of protection
    IP67

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 086030 on MQ Automation is $1,352.47. Order now.


Manufacturer warranty

086030 Euchner

$1,352.47

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$1,352.47

$1,352.47 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 086030 with other products

Weight

Additional information

Switching hysteresis

Assured operating distanc...

Repeat accuracy R

Rated operating distance ...

LED indicator

Connection cross-section

Voltage drop Ud

No-load current I0

Type of output

Off-state current Ir

Reverse polarity protecti...

EMC protection requiremen...

Residual ripple

Rated insulation voltage ...

Short circuit and overloa...

Utilization category acc....

Rated operating current I...

Number of NC contacts/NO ...

Operating voltage

Connection

Switching frequency

Number of switching eleme...

Proximity switch spacing

Ambient temperature

Material

Housing material

Switching principle

Design

Degree of protection

Series

Product Class

Assured operating distanc...

Assured release distance ...

Operating distance

Mission time

PFHD

For the approval acc. to ...

Additional feature

Performance Level

Category

Discrepancy time

Rated conditional short-c...

Test-pulse interval

Test pulses

Switching current

Output voltage

Turn-on time

Risk time according to EN...

Safety class

Degree of contamination (...

Rated impulse withstand v...

Fusing

Operating voltage DC

Extension of risk time ac...

Current consumption

Ready delay

Tightening torque

Installation orientation

Mounting method

Shock and vibration resis...

Mounting distance

Cable ambient temperature...

Cable ambient temperature...

Dynamic bending radius

Static bending radius

B10D

Version

Operating current

Switching element

Detent mechanism

Switching load

Connection rating

Overtravel

Extraction force

Actuating force

Mechanical life

Approach speed

Selected product

086030
0 in stock
086030
Euchner

086030 Euchner - MULTIPLE LIMIT SWITCH

Weight1.82574 lb

Additional information(Switching elements with 5mm...

Switching hysteresismax.0,5 mm

Assured operating distance Sa0 ... 4 mm (Dimension only ...

Repeat accuracy Rmax.5 %

Rated operating distance Sn5 mm

LED indicatorYes

Connection cross-section0,34 ... 1,5 mm² (Screw ter...

Voltage drop Udmax.2,5 V

No-load current I0max.15 mA

Type of outputPNP

Off-state current Irmax.0,001 mA

Reverse polarity protectionYes

EMC protection requirementsEN IEC 60947-5-2

Residual ripplemax.10 %

Rated insulation voltage Ui60 V

Short circuit and overload protection, pulsedYes

Utilization category acc. to EN 60947-5-2DC-13 (The output is to be ...

Rated operating current Ie250 mA

Number of NC contacts/NO contacts4

Operating voltage10 ... 55 V

ConnectionM25 x 1.5

Switching frequencymax.500 Hz

Number of switching elements4

Proximity switch spacing16 mm

Ambient temperature-25 ... 70 °C

MaterialPBT

Housing materialDie-cast aluminum

Switching principleNO + NC

DesignUpright, according to DIN 43...

Degree of protectionIP67

Series-

Product Class-

Assured operating distance Sao-

Assured release distance Sar-

Operating distance-

Mission time-

PFHD-

For the approval acc. to UL the following applies-

Additional feature-

Performance Level-

Category-

Discrepancy time-

Rated conditional short-circuit current-

Test-pulse interval-

Test pulses-

Switching current-

Output voltage-

Turn-on time-

Risk time according to EN 60947-5-3-

Safety class-

Degree of contamination (external, according to EN 60947-1)-

Rated impulse withstand voltage Uimp-

Fusing-

Operating voltage DC-

Extension of risk time according to EN 60947-5-3 per device-

Current consumption-

Ready delay-

Tightening torque-

Installation orientation-

Mounting method-

Shock and vibration resistance-

Mounting distance-

Cable ambient temperature (static)-

Cable ambient temperature (dynamic)-

Dynamic bending radius-

Static bending radius-

B10D-

Version-

Operating current-

Switching element-

Detent mechanism-

Switching load-

Connection rating-

Overtravel-

Extraction force-

Actuating force-

Mechanical life-

Approach speed-

119473
23 in stock
119473
Euchner

119473 Euchner - Non-contact safety switches CES-I-AR-.-C04-…, M12

Weight0.23589434 lb

Additional information-

Switching hysteresismin.1 mm

Assured operating distance Sa-

Repeat accuracy R≤ 10

Rated operating distance Sn-

LED indicator-

Connection cross-section-

Voltage drop Ud-

No-load current I0-

Type of outputSemiconductor output, p-swit...

Off-state current Irmax.0,25 mA

Reverse polarity protection-

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Residual ripple-

Rated insulation voltage Ui300 V

Short circuit and overload protection, pulsed-

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Rated operating current Ie-

Number of NC contacts/NO contacts-

Operating voltage-

ConnectionConnection cable PUR, length...

Switching frequencymax.1 Hz

Number of switching elements-

Proximity switch spacing-

Ambient temperature-

MaterialNBR 80 ±5 Shore

Housing materialPlastic, PBT

Switching principle-

Design-

Degree of protectionIP67

SeriesCES-AR

Product ClassSafety System

Assured operating distance Sao6

Assured release distance Sarmax.60 mm

Operating distance11 mm

Mission time20

PFHD4.1 x 10⁻⁹

For the approval acc. to UL the following appliesOperation only with UL class...

Additional featureRubber support included

Performance LevelPL e

Category4

Discrepancy timemax.10 ms

Rated conditional short-circuit current100 A

Test-pulse intervalmin.140 ms

Test pulsesmax.1,0 ms (Applies for a l...

Switching currentmax.50 mA

Output voltage0,8 x UB ... UB V DC

Turn-on timemax.400 ms

Risk time according to EN 60947-5-3max.260 ms

Safety classIII

Degree of contamination (external, according to EN 60947-1)3

Rated impulse withstand voltage Uimp1,5 kV

Fusing0,25 ... 8 A

Operating voltage DC24 V DC 15% ... 15% Regu...

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Current consumptionmax.35 mA (Without taking i...

Ready delay10 s

Tightening torquemax.0,8 Nm

Installation orientationAny

Mounting methodSurface mounting on metal

Shock and vibration resistanceIn acc. with EN 60947-5-3

Mounting distancemin.80 mm

Cable ambient temperature (static)-25 ... 65 °C

Cable ambient temperature (dynamic)-25 ... 65 °C

Dynamic bending radius10 x cable diameter

Static bending radius5 x cable diameter

B10D-

Version-

Operating current-

Switching element-

Detent mechanism-

Switching load-

Connection rating-

Overtravel-

Extraction force-

Actuating force-

Mechanical life-

Approach speed-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

Additional information-

Switching hysteresis-

Assured operating distance Sa-

Repeat accuracy R10 %

Rated operating distance Sn-

LED indicator-

Connection cross-section-

Voltage drop Ud-

No-load current I0-

Type of output2 semiconductor outputs, p-s...

Off-state current Irmax.0,25 mA

Reverse polarity protection-

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Residual ripple-

Rated insulation voltage Ui50 V

Short circuit and overload protection, pulsed-

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Rated operating current Ie-

Number of NC contacts/NO contacts-

Operating voltage5 ... 24 V

Connection2 plug connectors M12, 5-pin

Switching frequencymax.0,5 Hz

Number of switching elements-

Proximity switch spacing-

Ambient temperature-20 ... +55 °C

Material-

Housing materialFiber glass reinforced therm...

Switching principle-

Design-

Degree of protectionIP65 (Screwed tight plug co...

SeriesMGBS-P-I-AP

Product ClassSafety System

Assured operating distance Sao-

Assured release distance Sar-

Operating distance-

Mission time20 y

PFHD4.1 x 10 ⁻⁹

For the approval acc. to UL the following appliesOperation only with UL class...

Additional feature-

Performance LevelPL e

Category4

Discrepancy timemax.10 ms In acc. with EN ...

Rated conditional short-circuit current-

Test-pulse intervalmin.100 ms

Test pulsesmax.0,3 ms (Applies for a l...

Switching current1 ... 150 mA

Output voltage0 ... 1 V DC

Turn-on timemax.400 ms

Risk time according to EN 60947-5-3-

Safety classIII

Degree of contamination (external, according to EN 60947-1)3

Rated impulse withstand voltage Uimp0,5 kV

Fusing0,25 ... 8 A

Operating voltage DC24 V DC -15% ... 15% Rev...

Extension of risk time according to EN 60947-5-3 per device-

Current consumption40 mA

Ready delaymax.1 s

Tightening torque-

Installation orientationDoor hinge DIN right

Mounting method-

Shock and vibration resistanceIn acc. with EN 60947-5-3

Mounting distance-

Cable ambient temperature (static)-

Cable ambient temperature (dynamic)-

Dynamic bending radius-

Static bending radius-

B10D0,13 x 10⁶

VersionEmergency stop

Operating current1 ... 100 mA

Switching element2 pos. driven NC

Detent mechanismSnap-in bolt

Switching load24V DC, class 2 (Alternativ...

Connection rating1 W

Overtravel5 mm

Extraction force20 N

Actuating force10 N

Mechanical life1 x 10⁶

Approach speedmax.20 m/min

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 086030?
The price of 086030 on MQ Automation is $1,352.47. Order now.

Out if stock but available for backorder.

086030 Euchner - MULTIPLE LIMIT SWITCH

What can I help you find today?

Recommended parts