085613 Euchner Safety Relays

085613 on MQ Automation
Euchner
  • 085613
  • 085613
  • 085613

Part#:085613

Alt. Part#:ESM-BA301

Manufacturer:Euchner

Category:Safety Relays

Product Lifecycle:Active

162 in stock

Mar 15, 2025

Product description

085613 Euchner - Basic device ESM-BA3.., 3 safety contacts, 1 auxiliary contact, cat. 4

Product Details

  • Weight
    0.4629702 lb
  • Series
    ESM
  • Product Class
    safety relay
  • Mission time
    20 y (This value is dependent on the number of switching cycles and the switching current.)
  • Number of switching cycles
    max.500000 1/Jahr
  • PFHD
    1.2 x 10⁻⁸ (This value is dependent on the number of switching cycles and the switching current.)
  • Category
    4 (This value is dependent on the number of switching cycles and the switching current.)
  • Performance Level
    PL e (This value is dependent on the number of switching cycles and the switching current.)
  • Breaking capacity according to UL
    8A 250V AC / 3A 24V DC per contact
  • In compliance with
    EN ISO 13849-1: 2015; EN 62061: 2005 + AC: 2010 + A1: 2013 + A2: 2015; EN 50581: 2012 (RoHS)
  • Utilization category acc. to EN 60947-5-1
    3A , 250V
  • Cumulative current
    max.15 A For all contacts (If several ESM-BA3.. devices are closely spaced under load, the max. cumulative current at the ambient temperature of T=20°C is 9A; at T=30°C is 3A; at T=40°C is 1A. If these currents are exceeded, a spacing of 5mm between th
  • Switching current
    min.5 mA
  • Fusing
    10A gG
  • Switching voltage
    max.250 V
  • Type of output
    Relay contacts, floating and positively driven (redundant) (Positively driven relay according to EN 50205)
  • LED indicator
    2 status displays (green) for relays K1 and K2
  • Degree of contamination (external, according to EN 60947-1)
    2
  • Control voltage
    24 V 18,6 ... 26 V Start button
  • Rated impulse withstand voltage Uimp
    4 kV
  • Test voltage
    2,5 kV
  • Control current
    60 mA
  • Overvoltage category according to IEC EN 60664-1
    3
  • Connection cross-section
    0,14 ... 2,5 mm² (Connection terminal (size))
  • Connection rating
    2,3 W
  • Rated supply frequency
    50 ... 60 Hz
  • Rated insulation voltage Ui
    250 V
  • Mechanical life
    10 x 10⁶
  • Housing material
    Polyamide PA6.6
  • Connection
    Connection terminals
  • Weight
    0,23 kg
  • Operating voltage
    24 V -10% ... +10% (All the electrical connections must either be isolated from the mains supply by a safety transformer according to EN 61558-2-6 with limited output voltage in the event of a fault, or by other equivalent isolation measures.)
  • Number of auxiliary contacts
    1
  • Number of safety contacts
    3
  • Contact material
    AgSnO2
  • Degree of protection
    IP20
  • Mounting method
    Mounting rail 35mm according to DIN EN 60715 TH35
  • Ambient temperature
    -15 ... 40 °C (If several ESM-BA3.. devices are closely spaced under load, the max. cumulative current at the ambient temperature of T=20°C is 9A; at T=30°C is 3A; at T=40°C is 1A. If these currents are exceeded, a spacing of 5mm between the devices must
  • Length of control cable
    1000 m

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 085613 on MQ Automation is $233.79. Order now.


About the product

ESM-BA.. Use up to category 4 according to EN ISO 13849-1;LED status indicators;1-channel or 2-channel control;3 redundant safety contacts;1 auxiliary contact (monitoring contact);Short circuit and earth fault/ground fault monitoring


This item can ship in 3-5 days!

Manufacturer warranty

085613 Euchner

$233.79

Your price can be lower.
Log in or Create account to check your discount

Stock:

162

Select Qty:

$233.79

$233.79 each

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 085613 with other products

Weight

Series

Product Class

Mission time

Number of switching cycle...

PFHD

Category

Performance Level

Breaking capacity accordi...

In compliance with

Utilization category acc....

Cumulative current

Switching current

Fusing

Switching voltage

Type of output

LED indicator

Degree of contamination (...

Control voltage

Rated impulse withstand v...

Test voltage

Control current

Overvoltage category acco...

Connection cross-section

Connection rating

Rated supply frequency

Rated insulation voltage ...

Mechanical life

Housing material

Connection

Operating voltage

Number of auxiliary conta...

Number of safety contacts

Contact material

Degree of protection

Mounting method

Ambient temperature

Length of control cable

Overtravel

B10D

Additional feature

Solenoid duty cycle

Short circuit protection ...

Solenoid operating voltag...

Thermal rated current Ith

Insertion depth

Actuating force

Locking force FZh

Retention force

Extraction force

Locking force Fmax

Actuation frequency

Guard locking principle

Approach speed

Installation orientation

Number of door position N...

Switching principle

Number of guard lock moni...

Number of guard lock moni...

For the approval acc. to ...

Version

Operating current

Switching element

Repeat accuracy R

Detent mechanism

Discrepancy time

Off-state current Ir

Safety class

Turn-on time

Switching load

EMC protection requiremen...

Output voltage

Utilization category acc....

Current consumption

Operating voltage DC

Test-pulse interval

Test pulses

Shock and vibration resis...

Switching frequency

Ready delay

Selected product

085613
162 in stock
085613
Euchner

085613 Euchner - Basic device ESM-BA3.., 3 safety contacts, 1 auxiliary contact, cat. 4

Weight0.4629702 lb

SeriesESM

Product Classsafety relay

Mission time20 y (This value is depend...

Number of switching cyclesmax.500000 1/Jahr

PFHD1.2 x 10⁻⁸ (This value is d...

Category4 (This value is dependent...

Performance LevelPL e (This value is depende...

Breaking capacity according to UL8A 250V AC / 3A 24V DC per c...

In compliance withEN ISO 13849-1: 2015; EN 620...

Utilization category acc. to EN 60947-5-13A , 250V

Cumulative currentmax.15 A For all contacts ...

Switching currentmin.5 mA

Fusing10A gG

Switching voltagemax.250 V

Type of outputRelay contacts, floating and...

LED indicator2 status displays (green) fo...

Degree of contamination (external, according to EN 60947-1)2

Control voltage24 V 18,6 ... 26 V Start ...

Rated impulse withstand voltage Uimp4 kV

Test voltage2,5 kV

Control current60 mA

Overvoltage category according to IEC EN 60664-13

Connection cross-section0,14 ... 2,5 mm² (Connectio...

Connection rating2,3 W

Rated supply frequency50 ... 60 Hz

Rated insulation voltage Ui250 V

Mechanical life10 x 10⁶

Housing materialPolyamide PA6.6

ConnectionConnection terminals

Operating voltage24 V -10% ... +10% (All t...

Number of auxiliary contacts1

Number of safety contacts3

Contact materialAgSnO<sub>2</sub>

Degree of protectionIP20

Mounting methodMounting rail 35mm according...

Ambient temperature-15 ... 40 °C (If several E...

Length of control cable1000 m

Overtravel-

B10D-

Additional feature-

Solenoid duty cycle-

Short circuit protection according to IEC 60269-1-

Solenoid operating voltage-

Thermal rated current Ith-

Insertion depth-

Actuating force-

Locking force FZh-

Retention force-

Extraction force-

Locking force Fmax-

Actuation frequency-

Guard locking principle-

Approach speed-

Installation orientation-

Number of door position NC contacts-

Switching principle-

Number of guard lock monitoring NO contacts-

Number of guard lock monitoring positively driven contacts-

For the approval acc. to UL the following applies-

Version-

Operating current-

Switching element-

Repeat accuracy R-

Detent mechanism-

Discrepancy time-

Off-state current Ir-

Safety class-

Turn-on time-

Switching load-

EMC protection requirements-

Output voltage-

Utilization category acc. to EN 60947-5-2-

Current consumption-

Operating voltage DC-

Test-pulse interval-

Test pulses-

Shock and vibration resistance-

Switching frequency-

Ready delay-

098827
1 in stock
098827
Euchner

098827 Euchner - Safety switch STP-TWIN with door monitoring contact

Weight1.68873892 lb

SeriesSTP

Product ClassSafety switch

Mission time-

Number of switching cycles-

PFHDDepending on external contro...

CategoryDepending on external contro...

Performance LevelDepending on external contro...

Breaking capacity according to UL-

In compliance with-

Utilization category acc. to EN 60947-5-14A 230V

Cumulative current-

Switching current1 mA

Fusing-

Switching voltage12 V

Type of output-

LED indicator-

Degree of contamination (external, according to EN 60947-1)-

Control voltage-

Rated impulse withstand voltage Uimp2,5 kV

Test voltage-

Control current-

Overvoltage category according to IEC EN 60664-1-

Connection cross-section0,34 ... 1,5 mm²

Connection rating8 W

Rated supply frequency-

Rated insulation voltage Ui250 V

Mechanical life1 x 10⁶

Housing materialReinforced thermoplastic

ConnectionM20 x 1.5

Operating voltage-

Number of auxiliary contacts-

Number of safety contacts-

Contact materialSilver alloy, gold flashed

Degree of protectionIP67

Mounting method-

Ambient temperature-20 ... 55 °C

Length of control cable-

Overtravel5 mm

B10D5 x 10⁶

Additional featureWith mechanical key release ...

Solenoid duty cycle100 %

Short circuit protection according to IEC 60269-14A gG

Solenoid operating voltage24 V -15% ... +10%

Thermal rated current Ith4 A

Insertion depth24,5 mm

Actuating force35 N

Locking force FZh2000 N

Retention force20 N

Extraction force30 N

Locking force Fmax2500 N

Actuation frequencymax.1200 1/h

Guard locking principleClosed-circuit current princ...

Approach speedmax.20 m/min

Installation orientationAny

Number of door position NC contacts1

Switching principleSlow-action switching contac...

Number of guard lock monitoring NO contacts1

Number of guard lock monitoring positively driven contacts2

For the approval acc. to UL the following applies-

Version-

Operating current-

Switching element-

Repeat accuracy R-

Detent mechanism-

Discrepancy time-

Off-state current Ir-

Safety class-

Turn-on time-

Switching load-

EMC protection requirements-

Output voltage-

Utilization category acc. to EN 60947-5-2-

Current consumption-

Operating voltage DC-

Test-pulse interval-

Test pulses-

Shock and vibration resistance-

Switching frequency-

Ready delay-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

SeriesMGBS-P-I-AP

Product ClassSafety System

Mission time20 y

Number of switching cycles-

PFHD4.1 x 10 ⁻⁹

Category4

Performance LevelPL e

Breaking capacity according to UL-

In compliance with-

Utilization category acc. to EN 60947-5-1-

Cumulative current-

Switching current1 ... 150 mA

Fusing0,25 ... 8 A

Switching voltage-

Type of output2 semiconductor outputs, p-s...

LED indicator-

Degree of contamination (external, according to EN 60947-1)3

Control voltage-

Rated impulse withstand voltage Uimp0,5 kV

Test voltage-

Control current-

Overvoltage category according to IEC EN 60664-1-

Connection cross-section-

Connection rating1 W

Rated supply frequency-

Rated insulation voltage Ui50 V

Mechanical life1 x 10⁶

Housing materialFiber glass reinforced therm...

Connection2 plug connectors M12, 5-pin

Operating voltage5 ... 24 V

Number of auxiliary contacts-

Number of safety contacts-

Contact material-

Degree of protectionIP65 (Screwed tight plug co...

Mounting method-

Ambient temperature-20 ... +55 °C

Length of control cable-

Overtravel5 mm

B10D0,13 x 10⁶

Additional feature-

Solenoid duty cycle-

Short circuit protection according to IEC 60269-1-

Solenoid operating voltage-

Thermal rated current Ith-

Insertion depth-

Actuating force10 N

Locking force FZh-

Retention force-

Extraction force20 N

Locking force Fmax-

Actuation frequency-

Guard locking principle-

Approach speedmax.20 m/min

Installation orientationDoor hinge DIN right

Number of door position NC contacts-

Switching principle-

Number of guard lock monitoring NO contacts-

Number of guard lock monitoring positively driven contacts-

For the approval acc. to UL the following appliesOperation only with UL class...

VersionEmergency stop

Operating current1 ... 100 mA

Switching element2 pos. driven NC

Repeat accuracy R10 %

Detent mechanismSnap-in bolt

Discrepancy timemax.10 ms In acc. with EN ...

Off-state current Irmax.0,25 mA

Safety classIII

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Output voltage0 ... 1 V DC

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Current consumption40 mA

Operating voltage DC24 V DC -15% ... 15% Rev...

Test-pulse intervalmin.100 ms

Test pulsesmax.0,3 ms (Applies for a l...

Shock and vibration resistanceIn acc. with EN 60947-5-3

Switching frequencymax.0,5 Hz

Ready delaymax.1 s

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 085613?
The price of 085613 on MQ Automation is $233.79. Order now.

Out if stock but available for backorder.