077910 Euchner Safety Accessories

077910 on MQ Automation
Euchner

Part#:077910

Alt. Part#:CIA3SX1R1G08

Manufacturer:Euchner

Category:Safety Accessories

Product Lifecycle:Active

Product description

077910 Euchner - EVALUATION UNIT

Product Details

  • Weight
    0.452025 lb
  • Write distance
    0 ... 3 ... 6 mm (These values apply for the surface installation of the read head and the data carrier.)
  • Center offset
    max.2,5 mm (These values apply for the surface installation of the read head and the data carrier.)
  • Read distance
    0 ... 3 ... 6,5 mm (These values apply for the surface installation of the read head and the data carrier.)
  • Additional feature
    Shock - IEC60068-2-27 acceleration 30g, 6 shocks per axis, 11ms/half sinewave
  • Data protocol
    3964R via RS232/RS422
  • Data rate
    9600 kbit/s max.28800 kbit/s Can be selected via DIP switches
  • Output current
    10 mA
  • LED indicator
    STATE LED operational
  • Connection cross-section
    0,14 ... 2,5 mm²
  • Current consumption
    65 mA max.100 mA
  • Connection
    Plug-in screw terminals
  • Operating voltage DC
    20 ... 24 ... 28 V DC (All the electrical connections must either be isolated from the mains supply by a safety transformer according to IEC/EN 61558-2-6 with limited output voltage in the event of a fault, or by other equivalent isolation measures.)
  • Ambient temperature
    0 ... 55 °C
  • Mounting method
    Mounting rail 35mm according to DIN EN 60715 TH35
  • Housing material
    PA 6.6
  • Number of read heads
    max.1
  • Cable length
    max.5 m RS232
  • Degree of protection
    IP20

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 077910 on MQ Automation is $1,450.03. Order now.


Manufacturer warranty

077910 Euchner

$1,450.03

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$1,450.03

$1,450.03 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 077910 with other products

Weight

Write distance

Center offset

Read distance

Additional feature

Data protocol

Data rate

Output current

LED indicator

Connection cross-section

Current consumption

Connection

Operating voltage DC

Ambient temperature

Mounting method

Housing material

Number of read heads

Cable length

Degree of protection

Series

Product Class

Data interface

Utilization category acc....

Utilization category acc....

Switching current

Switching voltage

Mission time

PFHD

Category

Performance Level

For the approval acc. to ...

Repeat accuracy R

Discrepancy time

Output voltage

Turn-on time

Off-state current Ir

Type of output

Switching load

Risk time according to EN...

Safety class

Degree of contamination (...

Solenoid duty cycle

EMC protection requiremen...

Rated impulse withstand v...

Rated insulation voltage ...

Connection rating

Fusing

Solenoid operating voltag...

Test pulses

Test-pulse interval

Actuating force

Extension of risk time ac...

Extraction force

Overtravel

Locking force Fmax

Approach speed

Retention force

Locking force FZh

Guard locking principle

Mechanical life

Switching frequency

Ready delay

Installation orientation

Shock and vibration resis...

Selected product

077910
0 in stock
077910
Euchner

077910 Euchner - EVALUATION UNIT

Weight0.452025 lb

Write distance0 ... 3 ... 6 mm (These val...

Center offsetmax.2,5 mm (These values ap...

Read distance0 ... 3 ... 6,5 mm (These v...

Additional featureShock - IEC60068-2-27 accele...

Data protocol3964R via RS232/RS422

Data rate9600 kbit/s max.28800 kbit...

Output current10 mA

LED indicatorSTATE LED operational

Connection cross-section0,14 ... 2,5 mm²

Current consumption65 mA max.100 mA

ConnectionPlug-in screw terminals

Operating voltage DC20 ... 24 ... 28 V DC (All ...

Ambient temperature0 ... 55 °C

Mounting methodMounting rail 35mm according...

Housing materialPA 6.6

Number of read headsmax.1

Cable lengthmax.5 m RS232

Degree of protectionIP20

Series-

Product Class-

Data interface-

Utilization category acc. to EN 60947-5-1-

Utilization category acc. to EN 60947-5-2-

Switching current-

Switching voltage-

Mission time-

PFHD-

Category-

Performance Level-

For the approval acc. to UL the following applies-

Repeat accuracy R-

Discrepancy time-

Output voltage-

Turn-on time-

Off-state current Ir-

Type of output-

Switching load-

Risk time according to EN 60947-5-3-

Safety class-

Degree of contamination (external, according to EN 60947-1)-

Solenoid duty cycle-

EMC protection requirements-

Rated impulse withstand voltage Uimp-

Rated insulation voltage Ui-

Connection rating-

Fusing-

Solenoid operating voltage DC-

Test pulses-

Test-pulse interval-

Actuating force-

Extension of risk time according to EN 60947-5-3 per device-

Extraction force-

Overtravel-

Locking force Fmax-

Approach speed-

Retention force-

Locking force FZh-

Guard locking principle-

Mechanical life-

Switching frequency-

Ready delay-

Installation orientation-

Shock and vibration resistance-

113645
1 in stock
113645
Euchner

113645 Euchner - Interface adapter EKS Light FSA modular (supports all operating states)

Weight0.46517482 lb

Write distance-

Center offset-

Read distance-

Additional feature35 Resistance in switched-...

Data protocol-

Data rate-

Output current-

LED indicatorOperational

Connection cross-section0,14 ... 2,5 mm²

Current consumptionmax.70 mA

ConnectionPlug-in screw terminal

Operating voltage DC9 ... 24 ... 28 V DC (For u...

Ambient temperature0 ... 55 °C

Mounting methodMounting rail 35mm according...

Housing materialPA6.6 gray

Number of read headsmax.1

Cable length-

Degree of protection-

SeriesEKS Light

Product ClassElectronic-Key-System

Data interface4-bit parallel plus strobe, ...

Utilization category acc. to EN 60947-5-124V 50mA

Utilization category acc. to EN 60947-5-224V 50mA

Switching current1 ... 10 ... 50 mA High si...

Switching voltageU<sub>B</sub>-2 ... U<sub>B<...

Mission time-

PFHD-

Category-

Performance Level-

For the approval acc. to UL the following applies-

Repeat accuracy R-

Discrepancy time-

Output voltage-

Turn-on time-

Off-state current Ir-

Type of output-

Switching load-

Risk time according to EN 60947-5-3-

Safety class-

Degree of contamination (external, according to EN 60947-1)-

Solenoid duty cycle-

EMC protection requirements-

Rated impulse withstand voltage Uimp-

Rated insulation voltage Ui-

Connection rating-

Fusing-

Solenoid operating voltage DC-

Test pulses-

Test-pulse interval-

Actuating force-

Extension of risk time according to EN 60947-5-3 per device-

Extraction force-

Overtravel-

Locking force Fmax-

Approach speed-

Retention force-

Locking force FZh-

Guard locking principle-

Mechanical life-

Switching frequency-

Ready delay-

Installation orientation-

Shock and vibration resistance-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

Write distance-

Center offset-

Read distance-

Additional featureEscape release actuated by p...

Data protocol-

Data rate-

Output current-

LED indicator-

Connection cross-section-

Current consumption40 mA

Connection2 plug connectors M12, 5 and...

Operating voltage DC24 V DC -15% ... 15% Rev...

Ambient temperature-20 ... +55 °C

Mounting method-

Housing materialDie-cast zinc

Number of read heads-

Cable length-

Degree of protectionIP67/IP69/IP69K (Screwed ti...

SeriesCTP-AR

Product ClassSafety System

Data interface-

Utilization category acc. to EN 60947-5-1-

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Switching current1 ... 50 mA

Switching voltage-

Mission time20 y

PFHD4.1 x 10 ⁻⁹

Category4

Performance LevelPL e

For the approval acc. to UL the following appliesOperation only with UL class...

Repeat accuracy R10 %

Discrepancy timemax.10 ms In acc. with EN ...

Output voltage0,8xUB ... UB V DC

Turn-on timemax.400 ms

Off-state current Irmax.0,25 mA

Type of outputp-switching, short circuit-p...

Switching load24V DC, class 2 (Alternativ...

Risk time according to EN 60947-5-3max.260 ms

Safety classIII

Degree of contamination (external, according to EN 60947-1)3

Solenoid duty cycle100 %

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Rated impulse withstand voltage Uimp0,5 kV

Rated insulation voltage Ui50 V

Connection rating6 W

Fusing0,25 ... 8 A

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Test pulsesmax.1,0 ms (Applies for a l...

Test-pulse intervalmin.140 ms

Actuating force10 N

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Extraction force20 N

Overtravel5 mm

Locking force Fmax3900 N

Approach speedmax.20 m/min

Retention force20 N

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Guard locking principleClosed-circuit current princ...

Mechanical life1 x 10⁶

Switching frequencymax.0,5 Hz

Ready delay8 s

Installation orientationAny

Shock and vibration resistanceIn acc. with EN 60947-5-3

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 077910?
The price of 077910 on MQ Automation is $1,450.03. Order now.

Out if stock but available for backorder.

077910 Euchner - EVALUATION UNIT

What can I help you find today?