077750 Euchner Safety Proximity Sensors

077750 on MQ Automation
Euchner
  • 077750
  • 077750
  • 077750

Part#:077750

Alt. Part#:CES-A-C5E-01

Manufacturer:Euchner

Category:Safety Proximity Sensors

Product Lifecycle:Active

Product description

077750 Euchner - Non-contact safety switch CES-A-C5...

Product Details

  • Weight
    0.771617 lb
  • Series
    CES-A-.5
  • Product Class
    Safety System
  • Switching hysteresis
    min.1 mm (Applies for surface mounting on aluminum)
  • Assured operating distance Sao
    min.15 mm (Applies for surface mounting on aluminum)
  • Assured release distance Sar
    max.58 mm
  • Diagnostic Coverage (DC)
    90 %
  • Distance s, actuator
    min.6 mm
  • Operating distance
    22 mm (Applies on surface mounting on aluminum; in a non-metallic environment the typical operating distance increases to 30 mm.)
  • PFHD
    4.29 x 10⁻⁸
  • Performance Level
    PL e
  • Category
    3
  • Mission time
    20 y
  • Power supply output load
    24 V DC 18 ... 27 V DC
  • For the approval acc. to UL the following applies
    Operation only with UL class 2 power supply, or equivalent measures
  • Repeat accuracy R
    max.10 %
  • LED indicator
    Status LED
  • Discrepancy time
    max.120 ms
  • Rated conditional short-circuit current
    max.100 A
  • Utilization category acc. to EN 60947-5-2
    24V 400mA
  • Switching load
    max. DC 24 V, class 2
  • Output current
    1 ... 400 mA
  • Type of output
    Semiconductor outputs, p-switching, short circuit-proof, electrically decoupled (To ensure safety, both safety outputs (LA and LB) must be evaluated.)
  • Output voltage
    U(+LB) - 1,5 ... U(+LB) V DC
  • Rated insulation voltage Ui
    300 V (Tested by employers' liability insurance association up to 75 V.)
  • Degree of contamination (external, according to EN 60947-1)
    3
  • EMC protection requirements
    In acc. with EN 60947-5-3
  • Rated impulse withstand voltage Uimp
    1,5 kV
  • Fusing
    0,25 ... 8 A
  • Operating voltage DC
    18 ... 24 ... 27 V DC Regulated, residual ripple < 5 %
  • Current consumption
    80 mA
  • Mounting distance
    min.80 mm
  • Connection
    M12 plug connector, 8-pin, screen can be applied
  • Ambient temperature
    -20 ... 55 °C
  • Housing material
    Plastic, PBT
  • Weight
    0,4 kg
  • Ready delay
    max.3 s (After the operating voltage is switched on, the semiconductor outputs are switched off and the monitoring outputs are set LOW during the ready delay.)
  • Dwell time
    min.0,5 s (The dwell time of an actuator inside and outside the operating distance must be at least 0.5 s to ensure reliable detection of internal faults in the evaluation unit (self-monitoring).)
  • Installation orientation
    Any
  • Degree of protection
    IP65/IP67
  • Switching frequency
    max.1 Hz
  • Reaction time
    max.180 ms (Corresponds to the risk time according to EN 60947-5-3. This is the maximum switch-off delay for the safety outputs following removal of the actuator.)
  • Tightening torque
    max.0,6 Nm
  • Dimensions
    According to EN 60947-5-2: (LxWxH) 131x40x40

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 077750 on MQ Automation is $466.76. Order now.


About the product

Safety switch with integrated evaluation electronics;Pulsed signals can be switched;2 safety outputs (semiconductor outputs);Category 3 / PL e according to EN ISO 13849-1;Unicode


Manufacturer warranty

077750 Euchner

$466.76

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$466.76

$466.76 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 077750 with other products

Weight

Series

Product Class

Switching hysteresis

Assured operating distanc...

Assured release distance ...

Diagnostic Coverage (DC)

Distance s, actuator

Operating distance

PFHD

Performance Level

Category

Mission time

Power supply output load

For the approval acc. to ...

Repeat accuracy R

LED indicator

Discrepancy time

Rated conditional short-c...

Utilization category acc....

Switching load

Output current

Type of output

Output voltage

Rated insulation voltage ...

Degree of contamination (...

EMC protection requiremen...

Rated impulse withstand v...

Fusing

Operating voltage DC

Current consumption

Mounting distance

Connection

Ambient temperature

Housing material

Ready delay

Dwell time

Installation orientation

Degree of protection

Switching frequency

Reaction time

Tightening torque

Dimensions

Additional feature

Off-state current Ir

Test-pulse interval

Test pulses

Switching current

Turn-on time

Risk time according to EN...

Safety class

Extension of risk time ac...

Mounting method

Shock and vibration resis...

Cable ambient temperature...

Cable ambient temperature...

Dynamic bending radius

Material

Static bending radius

Selected product

077750
0 in stock
077750
Euchner

077750 Euchner - Non-contact safety switch CES-A-C5...

Weight0.771617 lb

SeriesCES-A-.5

Product ClassSafety System

Switching hysteresismin.1 mm (Applies for surfa...

Assured operating distance Saomin.15 mm (Applies for surf...

Assured release distance Sarmax.58 mm

Diagnostic Coverage (DC)90 %

Distance s, actuatormin.6 mm

Operating distance22 mm (Applies on surface m...

PFHD4.29 x 10⁻⁸

Performance LevelPL e

Category3

Mission time20 y

Power supply output load24 V DC 18 ... 27 V DC

For the approval acc. to UL the following appliesOperation only with UL class...

Repeat accuracy Rmax.10 %

LED indicatorStatus LED

Discrepancy timemax.120 ms

Rated conditional short-circuit currentmax.100 A

Utilization category acc. to EN 60947-5-224V 400mA

Switching loadmax. DC 24 V, class 2

Output current1 ... 400 mA

Type of outputSemiconductor outputs, p-swi...

Output voltageU(+LB) - 1,5 ... U(+LB) V D...

Rated insulation voltage Ui300 V (Tested by employers...

Degree of contamination (external, according to EN 60947-1)3

EMC protection requirementsIn acc. with EN 60947-5-3

Rated impulse withstand voltage Uimp1,5 kV

Fusing0,25 ... 8 A

Operating voltage DC18 ... 24 ... 27 V DC Regu...

Current consumption80 mA

Mounting distancemin.80 mm

ConnectionM12 plug connector, 8-pin, s...

Ambient temperature-20 ... 55 °C

Housing materialPlastic, PBT

Ready delaymax.3 s (After the operatin...

Dwell timemin.0,5 s (The dwell time o...

Installation orientationAny

Degree of protectionIP65/IP67

Switching frequencymax.1 Hz

Reaction timemax.180 ms (Corresponds to ...

Tightening torquemax.0,6 Nm

DimensionsAccording to EN 60947-5-2: (...

Additional feature-

Off-state current Ir-

Test-pulse interval-

Test pulses-

Switching current-

Turn-on time-

Risk time according to EN 60947-5-3-

Safety class-

Extension of risk time according to EN 60947-5-3 per device-

Mounting method-

Shock and vibration resistance-

Cable ambient temperature (static)-

Cable ambient temperature (dynamic)-

Dynamic bending radius-

Material-

Static bending radius-

119473
23 in stock
119473
Euchner

119473 Euchner - Non-contact safety switches CES-I-AR-.-C04-…, M12

Weight0.23589434 lb

SeriesCES-AR

Product ClassSafety System

Switching hysteresismin.1 mm

Assured operating distance Sao6

Assured release distance Sarmax.60 mm

Diagnostic Coverage (DC)-

Distance s, actuator-

Operating distance11 mm

PFHD4.1 x 10⁻⁹

Performance LevelPL e

Category4

Mission time20

Power supply output load-

For the approval acc. to UL the following appliesOperation only with UL class...

Repeat accuracy R≤ 10

LED indicator-

Discrepancy timemax.10 ms

Rated conditional short-circuit current100 A

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Switching load-

Output current-

Type of outputSemiconductor output, p-swit...

Output voltage0,8 x UB ... UB V DC

Rated insulation voltage Ui300 V

Degree of contamination (external, according to EN 60947-1)3

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Rated impulse withstand voltage Uimp1,5 kV

Fusing0,25 ... 8 A

Operating voltage DC24 V DC 15% ... 15% Regu...

Current consumptionmax.35 mA (Without taking i...

Mounting distancemin.80 mm

ConnectionConnection cable PUR, length...

Ambient temperature-

Housing materialPlastic, PBT

Ready delay10 s

Dwell time-

Installation orientationAny

Degree of protectionIP67

Switching frequencymax.1 Hz

Reaction time-

Tightening torquemax.0,8 Nm

Dimensions-

Additional featureRubber support included

Off-state current Irmax.0,25 mA

Test-pulse intervalmin.140 ms

Test pulsesmax.1,0 ms (Applies for a l...

Switching currentmax.50 mA

Turn-on timemax.400 ms

Risk time according to EN 60947-5-3max.260 ms

Safety classIII

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Mounting methodSurface mounting on metal

Shock and vibration resistanceIn acc. with EN 60947-5-3

Cable ambient temperature (static)-25 ... 65 °C

Cable ambient temperature (dynamic)-25 ... 65 °C

Dynamic bending radius10 x cable diameter

MaterialNBR 80 ±5 Shore

Static bending radius5 x cable diameter

105748
3 in stock
105748
Euchner

105748 Euchner - Non-contact safety switch CES-AR-CL2-... , plug connector M12, PUR

Weight0.29100984 lb

SeriesCES-AR

Product ClassSafety System

Switching hysteresismin.1 mm

Assured operating distance Saomin.14 mm

Assured release distance Sarmax.60 mm

Diagnostic Coverage (DC)-

Distance s, actuator-

Operating distance19 mm

PFHD1.9 x 10⁻⁹

Performance LevelPL e

Category4

Mission time20

Power supply output load-

For the approval acc. to UL the following appliesOperation only with UL class...

Repeat accuracy R≤ 10

LED indicator-

Discrepancy timemax.10 ms

Rated conditional short-circuit current100 A

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Switching load-

Output current-

Type of outputp-switching, short circuit-p...

Output voltage0,8 x UB ... UB V DC

Rated insulation voltage Ui75 V

Degree of contamination (external, according to EN 60947-1)3

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Rated impulse withstand voltage Uimp1,5 kV

Fusing0,25 ... 8 A

Operating voltage DC24 V DC 15% ... 15% Regu...

Current consumptionmax.50 mA (Without taking i...

Mounting distancemin.120 mm

ConnectionConnection cable PUR, length...

Ambient temperature-

Housing materialPlastic, PBT

Ready delay10 s

Dwell time-

Installation orientationAny

Degree of protectionIP67

Switching frequencymax.1 Hz

Reaction time-

Tightening torquemax.1 Nm

Dimensions-

Additional feature-

Off-state current Irmax.0,25 mA

Test-pulse intervalmin.140 ms

Test pulsesmax.1 ms (Applies for a loa...

Switching currentmax.50 mA

Turn-on timemax.400 ms

Risk time according to EN 60947-5-3max.260 ms

Safety classIII

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Mounting methodSurface mounting on metal

Shock and vibration resistanceIn acc. with EN 60947-5-3

Cable ambient temperature (static)-25 ... 65 °C

Cable ambient temperature (dynamic)-25 ... 65 °C

Dynamic bending radius10 x cable diameter

Material-

Static bending radius5 x cable diameter

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 077750?
The price of 077750 on MQ Automation is $466.76. Order now.

Out if stock but available for backorder.

077750 Euchner - Non-contact safety switch CES-A-C5...

What can I help you find today?

Recommended parts