071846 Euchner Safety Proximity Sensors
Part#:071846
Alt. Part#:CES-A-LNA-10V-071846
Manufacturer:Euchner
Category:Safety Proximity Sensors
Product Lifecycle:Active
Mar 16, 2025
Product description
071846 Euchner - Read head CES-A-LNA..., hard-wired encapsulated cable 10 m, PVC
Product Details
- Weight 0.74736618 lb
- Series CES read heads
- Product Class Safety System
- Cable length max.25 m
- Method of operation Inductive
- Power supply Via evaluation unit
- Cable ambient temperature (static) -25 ... 70 °C
- Connecting cable PVC, length 10m, Ø 4.6 mm, with crimped ferrules
- Connection Hard-wired encapsulated connection cable
- Weight 0,3 kg ((Incl 10m cable))
- Cable ambient temperature (dynamic) -5 ... 70 °C
- Housing material Reinforced thermoplastic (PPS), fully encapsulated
- Tightening torque max.1 Nm
- Installation orientation Any
- Degree of protection IP67/IP69K
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 071846 on MQ Automation is $58.72. Order now.
About the product
Cube-shaped design 42 x 25 mm;Hard-wired encapsulated cable made of PVC;Cable length 10 m;Two safety screws M4x14 included
This item can ship in 3-5 days!
Manufacturer warranty
071846 Euchner
$58.72
Your price can be lower.
Log in or Create account to check your discount
Stock:
Select Qty:
$58.72
$58.72 each
Fast Shipping & Delivery
Secure Payment Processing
Manufacturer warranty
Got Questions? We've Got Answers!
Need more details?
Feel free to chat with us
Compare 071846 with other products
Weight
Series
Product Class
Cable length
Method of operation
Power supply
Cable ambient temperature...
Connecting cable
Connection
Cable ambient temperature...
Housing material
Tightening torque
Installation orientation
Degree of protection
Switching hysteresis
Assured operating distanc...
Assured release distance ...
PFHD
Operating distance
Mission time
Performance Level
Category
For the approval acc. to ...
Repeat accuracy R
Discrepancy time
Off-state current Ir
Utilization category acc....
Rated conditional short-c...
Test pulses
Test-pulse interval
Output voltage
Switching current
Turn-on time
Risk time according to EN...
Type of output
Fusing
Rated impulse withstand v...
Rated insulation voltage ...
Degree of contamination (...
Safety class
EMC protection requiremen...
Extension of risk time ac...
Current consumption
Mounting distance
Operating voltage DC
Switching frequency
Ready delay
Mounting method
Static bending radius
Shock and vibration resis...
Dynamic bending radius
Selected product

071846
Euchner
071846 Euchner - Read head CES-A-LNA..., hard-wired encapsulated cable 10 m, PVC
Weight0.74736618 lb
SeriesCES read heads
Product ClassSafety System
Cable lengthmax.25 m
Method of operationInductive
Power supplyVia evaluation unit
Cable ambient temperature (static)-25 ... 70 °C
Connecting cablePVC, length 10m, Ø 4.6 mm, w...
ConnectionHard-wired encapsulated conn...
Cable ambient temperature (dynamic)-5 ... 70 °C
Housing materialReinforced thermoplastic (PP...
Tightening torquemax.1 Nm
Installation orientationAny
Degree of protectionIP67/IP69K
Switching hysteresis-
Assured operating distance Sao-
Assured release distance Sar-
PFHD-
Operating distance-
Mission time-
Performance Level-
Category-
For the approval acc. to UL the following applies-
Repeat accuracy R-
Discrepancy time-
Off-state current Ir-
Utilization category acc. to EN 60947-5-2-
Rated conditional short-circuit current-
Test pulses-
Test-pulse interval-
Output voltage-
Switching current-
Turn-on time-
Risk time according to EN 60947-5-3-
Type of output-
Fusing-
Rated impulse withstand voltage Uimp-
Rated insulation voltage Ui-
Degree of contamination (external, according to EN 60947-1)-
Safety class-
EMC protection requirements-
Extension of risk time according to EN 60947-5-3 per device-
Current consumption-
Mounting distance-
Operating voltage DC-
Switching frequency-
Ready delay-
Mounting method-
Static bending radius-
Shock and vibration resistance-
Dynamic bending radius-

105748
Euchner
105748 Euchner - Non-contact safety switch CES-AR-CL2-... , plug connector M12, PUR
Weight0.29100984 lb
SeriesCES-AR
Product ClassSafety System
Cable length-
Method of operation-
Power supply-
Cable ambient temperature (static)-25 ... 65 °C
Connecting cable-
ConnectionConnection cable PUR, length...
Cable ambient temperature (dynamic)-25 ... 65 °C
Housing materialPlastic, PBT
Tightening torquemax.1 Nm
Installation orientationAny
Degree of protectionIP67
Switching hysteresismin.1 mm
Assured operating distance Saomin.14 mm
Assured release distance Sarmax.60 mm
PFHD1.9 x 10⁻⁹
Operating distance19 mm
Mission time20
Performance LevelPL e
Category4
For the approval acc. to UL the following appliesOperation only with UL class...
Repeat accuracy R≤ 10
Discrepancy timemax.10 ms
Off-state current Irmax.0,25 mA
Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...
Rated conditional short-circuit current100 A
Test pulsesmax.1 ms (Applies for a loa...
Test-pulse intervalmin.140 ms
Output voltage0,8 x UB ... UB V DC
Switching currentmax.50 mA
Turn-on timemax.400 ms
Risk time according to EN 60947-5-3max.260 ms
Type of outputp-switching, short circuit-p...
Fusing0,25 ... 8 A
Rated impulse withstand voltage Uimp1,5 kV
Rated insulation voltage Ui75 V
Degree of contamination (external, according to EN 60947-1)3
Safety classIII
EMC protection requirementsIn acc. with EN IEC 60947-5-...
Extension of risk time according to EN 60947-5-3 per devicemax.5 ms
Current consumptionmax.50 mA (Without taking i...
Mounting distancemin.120 mm
Operating voltage DC24 V DC 15% ... 15% Regu...
Switching frequencymax.1 Hz
Ready delay10 s
Mounting methodSurface mounting on metal
Static bending radius5 x cable diameter
Shock and vibration resistanceIn acc. with EN 60947-5-3
Dynamic bending radius10 x cable diameter
Weight0.52029032 lb
SeriesCES-AP
Product ClassSafety System
Cable length-
Method of operation-
Power supply-
Cable ambient temperature (static)-40 ... 65 °C
Connecting cable-
Connectionconnection cable PVC, length...
Cable ambient temperature (dynamic)0 ... 65 °C
Housing materialPlastic, PBT
Tightening torquemax.1 Nm
Installation orientationAny
Degree of protectionIP67, IP69K
Switching hysteresismin.1 mm
Assured operating distance Saomin.14 mm
Assured release distance Sarmax.60 mm
PFHD1.8 x 10⁻⁹
Operating distance19 mm
Mission time20
Performance LevelPL e
Category4
For the approval acc. to UL the following appliesOperation only with UL class...
Repeat accuracy R≤ 10
Discrepancy timemax.10 ms
Off-state current Irmax.0,25 mA
Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...
Rated conditional short-circuit current100 A
Test pulsesmax.0,3 ms (Applies for a l...
Test-pulse intervalmin.100 ms
Output voltage0,8 x UB ... UB V DC
Switching currentmax.50 mA
Turn-on timemax.300 ms
Risk time according to EN 60947-5-3max.260 ms
Type of outputp-switching, short circuit-p...
Fusing0,25 ... 8 A
Rated impulse withstand voltage Uimp1,5 kV
Rated insulation voltage Ui75 V
Degree of contamination (external, according to EN 60947-1)3
Safety classIII
EMC protection requirementsIn acc. with EN IEC 60947-5-...
Extension of risk time according to EN 60947-5-3 per device-
Current consumptionmax.30 mA (Without taking i...
Mounting distancemin.400 mm
Operating voltage DC24 V DC 15% ... 15% Regu...
Switching frequencymax.1 Hz
Ready delay0,5 s
Mounting methodSurface mounting on metal
Static bending radius5 x cable diameter
Shock and vibration resistanceIn acc. with EN 60947-5-3
Dynamic bending radius10 x cable diameter

071846
Euchner
071846 Euchner - Read head CES-A-LNA..., hard-wired encapsulated cable 10 m, PVC
Weight0.74736618 lb
SeriesCES read heads
Product ClassSafety System
Cable lengthmax.25 m
Method of operationInductive
Power supplyVia evaluation unit
Cable ambient temperature (static)-25 ... 70 °C
Connecting cablePVC, length 10m, Ø 4.6 mm, w...
ConnectionHard-wired encapsulated conn...
Cable ambient temperature (dynamic)-5 ... 70 °C
Housing materialReinforced thermoplastic (PP...
Tightening torquemax.1 Nm
Installation orientationAny
Degree of protectionIP67/IP69K
Switching hysteresis-
Assured operating distance Sao-
Assured release distance Sar-
PFHD-
Operating distance-
Mission time-
Performance Level-
Category-
For the approval acc. to UL the following applies-
Repeat accuracy R-
Discrepancy time-
Off-state current Ir-
Utilization category acc. to EN 60947-5-2-
Rated conditional short-circuit current-
Test pulses-
Test-pulse interval-
Output voltage-
Switching current-
Turn-on time-
Risk time according to EN 60947-5-3-
Type of output-
Fusing-
Rated impulse withstand voltage Uimp-
Rated insulation voltage Ui-
Degree of contamination (external, according to EN 60947-1)-
Safety class-
EMC protection requirements-
Extension of risk time according to EN 60947-5-3 per device-
Current consumption-
Mounting distance-
Operating voltage DC-
Switching frequency-
Ready delay-
Mounting method-
Static bending radius-
Shock and vibration resistance-
Dynamic bending radius-
About the manufacturer

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.
Recently viewed products
Relevant products
FAQ
What is the price of 071846?
The price of 071846 on MQ Automation is $58.72. Order now.
Out if stock but available for backorder.
071846 Euchner - Read head CES-A-LNA..., hard-wired encapsulated cable 10 m, PVC
Similar products from: Safety Proximity Sensors
What can I help you find today?